Data collection platform
CPU: not less than 64 Bit with embedded operation system (OS) software (Windows CE, Linux, other) for the running of multiple independent computer programs (multitasking);
Non-volatile memory on a flash technologies basis
Internal monitoring timer (watchdog timer) for automatic device reset in the event of failures internal battery backup for clock
Inputs:
Possibility to interface 10 different electronic sensors having analog or digital outputs, including: Volt, 4-20 mA, tipping bucket, event counters.
Include following input channels:
Not less than 8 analog inputs galvanically separated (ADC resolution ≥ 16 bit)
No less than 1 digital inputs: RS-485
SDI-12 protocol support with capability to connect up to 32 digital sensors
Time Stamp: Individually with 1 sec. resolution
Data Storage: At least 1.000.000 values, non-Volatile memory (3 years autonomy)
Display
LCD display with backlight, at least 2-line, 20-character
Visualization of measures collected, Visualization of operational and diagnostics parameters
Protection: Lighting, over voltage, and reverse voltage protection (fuse)
Operating Voltage: 10.0 to 16.0 VDC
Power Consumption: < 3 mA quiescent
Interface
Standard RS232 and USB thumb drive, Window based user-friendly
software for data download and parameters configuration on site
suitable for data logger communication and off-line data transfer to PCs
English language version
Enclosure: IP 66 enclosure for a humid environment
Operating Conditions: Temperature: -10°C to 60°C; Humidity: 0 – 100 % (without condensation);
NEMA Enclosure and Accessories
NEMA Enclosure safety locks of good quality for electronic equipment
The enclosure is big enough to host comfortably the data logger, battery, solar panel, regulator, satellite transmitter unit, GSM unit, battery charger, electrical protection devices, other electronic equipment.
Material can be stainless steel plate or UV resistant synthetic material protection degree IP67 (NEMA 4) or better
safety locks of good quality
Metallic support to fix the NEMA enclosure to a metallic mast
The NEMA case is installed in such a way as to defer vandalism
All cables is protected by a robust flexible conduit and no cables is exposed to outdoor conditions.
Cabling between the equipment is well organized and protected adequately for easy maintenance.