Our Products
Energy Efficiency In Refrigeration Systems

Energy Efficiency In Refrigeration Systems

Product Code: LBNY-0005-125000103

Categories: Thermal Engineering and HVAC Equipment

Tags: Energy Efficiency In Refrigeration Systems

3145

Download PDF Enquire Now
  • Description

Heat Exchanger For Refrigerant Super cooling Can Be Added Via Valves
Glycol-Water Circuit Includes Pump And Tank With Heater Serving As Cooling Load At The Evaporator
Refrigeration System In Multi compressor Operation To Investigate Energy Efficiency
Multi compressor Controller For The Parallel Operation Of The Compressors
Refrigeration Circuit With 3 Compressors Connected In Parallel, Condenser, Thermostatic Expansion Valve And Coaxial Coil Heat Exchanger As Evaporator
Separation Of Oil From The Refrigerant On The Delivery Side And Return To Fan At the condenser with adjustable speed
The Intake Side Of The Compressors.



Specification

Condenser with fan
Volumetric air flow rate: 1250m/h
Capacity: 4100W
3 compressors
Power consumption: each 1156W at -10C/55C
Refrigeration capacity: each 1584W at -10C/55C
Coaxial coil heat exchanger capacity
4kW at T=9K; 0,6m/h glycol-water mixture
Glycol-water mixture pump
Max. head: 5,6m
Max. Flow rate: 4,2m/h
Heater power: 3kW
Tank
Refrigeration circuit receiver: 5,8L
Glycol-water mixture: 23L
Measuring ranges:
Pressure: 1x -1...9bar, 1x -1...24bar
Flow rate: 1x 1...25l/min
Temperature: 4x 0...100c, 4x -100c...100c
Compressor power: 0...4995W.

Support