Our Products
Pipe Friction Training Panel

Pipe Friction Training Panel

Product Code: LBNY-0005-12500041

Categories: Thermal Engineering and HVAC Equipment

Tags: Pipe Friction Training Panel

3083

Download PDF Enquire Now
  • Description

The trainer is supplied from the water mains. The flow rate is adjusted using valves and measured using a rotameter. Four different pipe sections are fitted to a panel. Each section can be individually selected using ball valves. The measuring points are 1m apart. The pressure drop over a pipe section is measured using a digital, battery-operated differential manometer. To keep measuring inaccuracies as low as possible, the pressure is measured using annular chambers.



Specification

Flow rate can be adjusted via valves
Pressure measurement with annular chambers
Investigations on pipes
4 Pipe section of the same lengths and different materials as measured objects
Flow rate measurement using rotameter
Water connections made using quick-release couplings
Pipe sections can be selected via ball valves
Pressure measurement with digital differential pressure manometer, battery-operated.

Support