Our Products
Fully Automated Rapid Bacterial Identification and AST Testing System

Fully Automated Rapid Bacterial Identification and AST Testing System

17

Download PDF Enquire Now
  • Description

Fully Automated Rapid Bacterial Identification and AST Testing System



Specification

The system includes an ADVANCED EXPERT SYSTEM (AES) that analyzes MIC patterns and detects phenotypes for most organisms tested.
This helps optimize laboratory efficiency for lean laboratory management.
Rapid results allow clinicians to discontinue empiric therapy and prescribe targeted therapy, resulting in improved patient outcomes and enhanced antibiotic stewardship.
Fully Automated, High-throughput & random-access bacterial identification & antibiotic susceptibility system.
System should be able to perform incubation and result-interpretation simultaneously for identification of Aerobic, fastidious bacteria, Anaerobic bacteria, yeast and fungi).
with highest discriminative between species by different Biochemical medias and MIC determination by micro dilution Method
Throughput: - Identification and Drug Susceptibility test (both ID & AST) less than 12 hours.
Method : modification of classical method i.e fermentation  ,Oxidation  degradation hydrolysis  of various  Substrates utilizes  Chromogenic and Flurogenic substrate   as well as Single carbon source      
Test card read kinetically: at least every 15 min for optimum time to result or less
Software: - Advanced Software that maintains consistency of Identification and Susceptibility test results.
Database covering: 100,000 reference databases with more than 2,000 referenced phenotypes &20,000 MIC distributions.
Capacity: 120 cards per instrument or equivalent
Bacterial Identification: System able to  identify or detect all Gram-negative Bacilli, Gram positive bacilli gram negative cocci, Staphylococci, Streptococci, Yeast &/or Enterococci. 45 and more  biochemical  chambers
Antimicrobial detection system - Multiple drug resistant monitoring: MRSA, BETA-lac, VRE, VRSA,HLAR,ESBLs.,mecA iMLSb, HLMUPH, CPO, BL
Sensitivity panels:- should be able to provide customized sensitivity panels as per the need of user with different configurations. Fastidious bacteria with the highest discriminative between species and more than 18 antibiotic list.
Uses up-to-date AST formulations based  on updated CLSI guidelines.
Antibiotics are divided into A/B/C/U group to report MIC results which would help doctors to choose the appropriate antibiotics.
Broth based Micro dilution   for AST
Allows remote support and troubleshooting through a secure connection and enables automatic software, firmware and security updates charge free
System should have reader and built-in incubator for incubating/reading the plates/test panels/ cards.
Result Output: - User definable expert rules, which can be configured as enabled v/s disabled and manual interpretation v/s automated interpretation.
Data management and Connectivity:- LIS/HIS and WHONET support.
Both  0.5 Inoculum  Density and 0.25 inoculum ,02-4 MLF configuration  
System supplied with a minimum 25 nos. of plates/test panels/cards and related consumables for identification of aerobic gram negative and gram positive bacteria, anaerobic bacteria, yeast, fungi and microbial community analysis
Quality Certificates  : US FDA or CE or both
System Interfaces: RS232 serial interface, bidirectional
Operating Temperature: +15?C to +30?C
Installation/Training Commissioning: The supplier providing installation, and commissioning of the device. IQ,OQ,and PQ required.
UPS and Stabilizer: - Suitable System with a minimum of 1 hour back-up. capability  
Start-up reagents- Company will provide 500 tests of ID+AST (joined) panel as per user requirement.
Peripheral ports :- Full traceability with pre-applied barcodes , support host computers, external printers, more than 4 USB ports
Quality Control Module:  should be able to Manages and reports quality control results
Electrical Requirements: 220V + 10% (50-60 Hz)
Should have external printing capability
UPS and stabilizer as one unit
Thermal printer paper-20mm
Relative Humidity: <85%
Compatible UPS with maintenance free battery and Resettable over current breaker (voltage regulator
Resettable over-current mains fuse to be incorporated
Electrical protection :Shall meet IEC-60601-1-2 :2001

Fully Automated Rapid Bacterial Identification and AST Testing System, Fully Automated Rapid Bacterial Identification and AST Testing System Equipments, Fully Automated Rapid Bacterial Identification and AST Testing System Tools, Fully Automated Rapid Bacterial Identification and AST Testing System Tool Kits, Fully Automated Rapid Bacterial Identification and AST Testing System Manufacturers, Fully Automated Rapid Bacterial Identification and AST Testing System Suppliers from India, China, Kenya