Gas Chromatograph With Flame Ionisation Detector (FID)

Gas Chromatograph With Flame Ionisation Detector (FID)

Product Code: LBNY-0001-500010

Categories: Analytical Instrument

Tags: Gas Chromatograph With Flame Ionisation Detector (FID)

117

Download PDF Enquire Now
  • Description

Gas Chromatograph With Flame Ionisation Detector (FID)



Specification

Gas Chromatograph With Flame Ionisation Detector (FID)

General Features:
Capillary Gas chromatograph equipped with FID
Gas Chromatograph
GC Oven – 1 pc.
Temperature range: ambient +3 °C to 450 °C .
Temperature set point resolution: 0.1 °C .
Number of ramps/plateaus: 32/33 .
Heating rate setting: 125 °C/min .
Oven cool down: 450 °C to 50 °C in less than 4 min . tes
Heated zones: up to seven .
Retention time repeatability: <0.0008 min .
Peak area repeatability: <0.3% RSD .
GC liquid and headspace autosampler – 1 pc.
Liquid sampling:
Injection Speed: Selectable from 0.1 μL/s to 2000 μL/s (Liquid Sampling); . .
Injection Increments: 1% of the syringe volume
Syringe wash with 4 Solvent bottles of 4 mL
Pre- and/or post-injection syringe wash: 0-15 rinses
Waste bottle capacity: 40 mL
Sample capacity: 155 vials (2 mL) .
Programable filling strokes for bubble elimination: 0-15 strokes
Injection speed range: 1-60,000.00 μL/min .
Carryover: <0.001% .
Linearity: <4% RSD .
Area repeatability: <0.3% RSD .
Injection Speed: -Selectable 1 to 100 mL/min, in 1 mL/min Increments
Headspace Sampling
Vial volumes Compatible with 2, 10 and 20 mL vials .
Injection volume range 0.1 to 5 mL in 0.1 mL steps .
Injection speed 1 to 100 mL/min, in 1 mL/min increments .
Syringe flush capability: With inert gas
GC Inlet – 1 pc.
Programmed Temperature Vaporizer (PTV)
Split ratio: up to 12500:1 .
Pressure range: 0-1050 kPa .
Pneumatic control modes: Constant and programmed pressures, Constant and programmed flows .
Split flow: OFF or from 0-1250 mL/min in 0.1 mL/min increments .
Temperature range: 5 °C up to 450 °C .
Temperature programming of up to 3 ramps at up to 870 °C/min .
PTV cooling rate: from 350 °C to 50 °C in 3.5 min .
Purge flow: OFF or from 0.5-50 mL/min in 0.1 mL/min increments .
Supports hot/cold split and splitless modes, and large volume injections .
Flame Ionisation Detector (FID) with Flameout detection and automatic re-ignition – 1 pc.
Detectable Level (MDL): <1.2 pg C/s .
Sensitivity: 0.03 Coulombs/gC .
Linear dynamic range: >107 .
Temperature: 450°C settable in 0.1°C steps .
Integrated gas control
PC system
INTEL Quad Core Processor, 2.4 GHz
16 GB SDRAM
1 TB Hard Disk
DVD-RW Drive
6 USB 2.0 and 3.0 ports
1GB Dedicated Graphics Processor
International keyboard
Optical Mouse
Microsoft Windows 10 (or equivalent) 64bit professional operating system  
MS Office 2021 small business edition  (English)
Documentation (English)
Mouse and keyboard software (English)
23" LED flat screen monitor
Sowtware for control of the instrument, data acquisition, processing and reporting.

Gas Chromatograph With Flame Ionisation Detector (FID), Gas Chromatograph With Flame Ionisation Detector (FID) Equipments, Gas Chromatograph With Flame Ionisation Detector (FID) Tools, Gas Chromatograph With Flame Ionisation Detector (FID) Tool Kits, Gas Chromatograph With Flame Ionisation Detector (FID) Manufacturers, Gas Chromatograph With Flame Ionisation Detector (FID) Suppliers from India, China, Kenya