Inductively Coupled Plasma Mass Spectroscopy ICP-MS
Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) for elemental analysis at a level of sub parts per trillion (ppt) to percent in food samples, environmental samples like soil, chemicals, plants, minerals and the like samples.
Features: Protect quadruples ion deflector from sample deposits and eliminating cleaning on the cones, fully computer controlled, bench top ICP-MS system. It includes an installation kit with installation solution, gas line, cooling line, flexible vent duct tubing included. Waste container, sample introduction torch and interface cones.
Which has a robust plasma system
Ultra-high matrix introduction (UHMI) technology combined with optional Integrated Sample Introduction System (ISIS) and ODS ensures almost any sample to be run and quantified across the widest dynamic range, ideal for environmental, geochemical, food, pharmacy, and general testing laboratories with focus on fast turn-around time.
With powerful all matrix solution introduction system that enable to routinely measure samples containing high total dissolved solids without manual dilution, with a glass cyclonic high sensitivity spray chamber
Dedicated hydrofluoric-acid-resistant sample introduction system. data acquisition speed 100,000 points/sec and optimize productivity with the lowest maintenance
Widest dynamic range—dynamic range up to 12 orders of magnitude from sub-ppt to percent-level concentrations, which enable to measure trace elements and majors in the same run.
Which provides increased gain and reduced background for improved signal to noise ratio, Provides short integration times for accurate analysis of transient signals.
Improved productivity— eliminates virtually all maintenance requirements and low gas consumption
RF coil that never needs to be changed and a unique, tightly controlled ion path that creates the cleanest analytical environment of any ICP-MS.
Automatically checks system specifications and tuning procedures before a run to ensure all parameters are met for faster start-up and more accurate results Raise alarms when preventative maintenance is due, to keep the instrument in peak operating conditions,
Displays real-time information on key instrument components so one can monitor the entire system
Increases workflow efficiency and data reliability by allowing the user to automatically schedule instrument optimizations and procedures, Including auto-start and shut down, tuning, and multi method analyses as required,
Displays the sample run list, Including method and sample types, in a convenient dialog box before the start of a run,
Displays single- or multi-view calibrations during a run, giving the real-time information on detection limits and background equivalent concentrations.
Allows review of the complete instrument performance history in a single panel so that the user can quickly check parameters used on a specific day and track and compare current performance data in real time. Nebulizers: Micro Mist Glass concentric nebulizer.
Cross/Micro flow/PFA nebulizer for HF medium.
Direct Inject nebulizer.
Peltier-Cooled Spray Chambers
Quartz Scott-type.
PFA Spray chamber for HF medium.
Standard cyclonic type suitable for different kind of samples.
Peristaltic Pump and spray chamber: 3-4 Channel, integrated low pulse peristaltic pump
A cyclonic sample introduction system with concentric nebulizer
Injectors: Plasma Ion Source: Alumina/quartz/PFA injectors suitable for HF medium and other sample environments.
Plasma Gas Control: A built in 34 MHz free running ICP source with plasma lock technology to control ion energies For makeup and Carrier Gases.
Torch: One-piece glass/quartz torch with a minimum diameter of 2.5 mm for efficient matrix decomposition and that provides one handed removal and replacement
Provision for Auto-alignment of the torch after routine maintenance with reproducibility better than 0.1 mm in x-y-z directions.
Shield Torch Mechanism: Shield Torch mechanism capable of reducing the plasma ion energy spread and provide for efficient cool plasma operations.
Quadruple Mass Analyzer: A quadruple stage vacuum system utilizing a triple inlet turbo molecular pump
RF Generator: Fully digital RF generator.
Mass Range: 1-285 amu Abundance
Sensitivity: 5x10-7 or lower.
The detection limit must be: 9Be - <0.5ng/L (ppt)
Oxide ratio represented by CeO/Ce: 59Co - <0.5ng/L (ppt)
Doubly charged ions represented by Ba+ /Ba 2+ : 115In - <0.25ng/L (ppt), 238U - <0.25ng/L
Mean background of the system: 1amu at 1amu
Note: The instrument must be Computer configured and fully controllable with computer. Computer should be supplied with the instrument.
Auto-sampler: Sample capacity-Fast Ready Dual Rinse standard position:10, Rinse Position 2 and total of 360 sample position
Vial Volume Capacity: 10ml and 50ml vials
Number of Tray: 4 racks/360 samples and 8 position of 50ml
Software control and rinsing type: Fully integrated software control, and programmable rinse functions Including Intelligent Rinse and Pre-emptive Rinse.
Built-in pumped rinse station-to protect sample carry over or cross-contamination
Component type: All component must be corrosion resistant at normal condition
Auto sampler: High speed Auto sampler for faster sample throughput, maximum of 3s
Software: Which allows to simply select the elements of target to measure and the software shall help pick the appropriate masses based on abundance and potential interferences, and eliminate the need for method development in many applications,
Flexible quality control checks – Automate the monitoring of everything from calibration to internal standard responses during a run, ensuring reliable data even during unattended operation.
Acquisition in full spectrum, peak hopping and time resolved modes.
Data analysis that is supported using isotope ratios, isotope dilution, external and standard calibrations with or without internal standards.
Data archival and retrieval functions.
Auto-tuning of the instrument from a cold start.
Data Reporting Programming of customized analysis routines.
System diagnostics software
21 CFR part 11 compatibility
Which enables offline data analysis
Power supply: Single Phase, 220±10 V, 50/60 Hz power supply
Uninterrupted Power Supply: shall be supplied with 10KVA system with 60 min backup.
Operational environmental Requirements: The room temperature should be between 15 and 30 °C
The relative humidity should be between 20 and 80%, non-condensing.
Compacted size - Suitable to put on regular lab. bench
Easy to move or to lift when needed and during cleaning.
Accessories: Sample introduction kit with Platinum HF
Platinum Sampler and Skimmer Cones
Hyper Skimmer Cone with screw, O-ring
Cone removal tool
Quartz Demountable Injector
Plasma load coil
Torch and all torch parts
Injectors suitable for variety of matrix
Sample introduction modules (hoses)
Concentric Nebulizers with its PFA connect fittings (Glass, Quartz and PFA types)
Nebulizer Fittings and Capillaries
Spray Chamber and Spray Chamber Components
Peristaltic Pump Tubing Including sample uptake and drain tubing
Auto-sampler Tubes or vials 200pc of 15ml and 50pcs for 50ml
Sample introduction kit, Solution kit, Standard solution, Chiller coolant mix
Organics samples Introduction kit
Inductively Coupled Plasma Mass Spectroscopy ICP-MS, Inductively Coupled Plasma Mass Spectroscopy ICP-MS Equipments, Inductively Coupled Plasma Mass Spectroscopy ICP-MS Tools, Inductively Coupled Plasma Mass Spectroscopy ICP-MS Tool Kits, Inductively Coupled Plasma Mass Spectroscopy ICP-MS Manufacturers, Inductively Coupled Plasma Mass Spectroscopy ICP-MS Suppliers from India, China, Kenya