Lab Tender Suppliers Africa and Lab Equipment Africa Kenya, South Africa, Ivory Coast, Cameroon, Niger, Burkina Faso, Mayotte, Sao Tome, Seychelles, Zambia, Chad, Somalia, Senegal, Zimbabwe, Guinea, Rwanda, Uganda, Sudan, Algeria, Morocco, Angola, Ghana, Mozambique, Madagascar, Benin, Burundi, Tunisia, South Sudan, Botswana, Namibia, Gabon, Lesotho, Guinea Bissau, Equatorial Guinea, Mauritius, Eswatini, Djibouti, Reunion, Comoros, Cape Verde, Western Sahara, Mali, Malawi, Nigeria, Ethiopia, Egypt, DR Congo, Tanzania, Togo, Sierra Leone, Libya, Congo, Central African Republic, Liberia, Mauritania, Eritrea, Gambia Ministerial Tender Board Lab Equipment India, Ministry of School Education Lab, Vocational Training Lab Tenders Suppliers India
Lab Instruments School Training Lab Equipment Suppliers India
Device is accurate from 0.5 to 4 McFarland units in increments of 0.1 units
Used with Calibration Kit
Instrument can be used for any laboratory procedure that requires inoculum density adjustments
Includes: Nephelometer, AC adapter and 4 AA alkaline batteries (not rechargeable).
Perfect for the plant, field or lab, this simple yet powerful turbidity meter offers an impressive array of features. Use the Infrared (IR) LED light source to comply and reliably measure turbidity with auto-ranging values from 0 to 1000 NTU. Generate an accurate turbidity reading quickly with the Turbidity Meter. This IP67 waterproof meter offers a long battery life averaging about 3000 tests.
Features:
Auto ranging from 0 to 1000 NTUs
Uses Nephelometric principle with 90° detection
Easy to read results from the large, bright LCD display in a variety of work environments
No mixing or diluting with EPA-approved polymer bead primary standards for faster calibration.
Utilize advanced features with the Turbidity Meter, including dual light sources and drinking water/wastewater methods approved for U.S. EPA regulatory reporting.
This IP67 waterproof meter records 100 data points and offers an average battery life of 2500 hours intermittent use.
Log data into internal memory, or order AQ4CBL cable to send data to printer or download to a computer for easy time- and date-stamped results storage.
Keep pace with changing regulatory protocols and use White Light LED to comply with EPA 180.1 requirements or Infrared (IR) LED to comply with ISO 7027 requirements. Select from measure modes including EPA 180.1, ISO Nephelometric, ISO Absorbance, % transmittance, EBC and ASBC.
Nephelometric and ratio metric measurements with auto ranging
IP67 waterproof portable turbidity meter
Dual source to comply with EPA 180.1 and ISO 7027
Readings in the range of 0 to 1000 NTU with a choice of units: NT, FTU, FNU, ASBC or EBC.
Ensure your Turbidity Meter has the accessories it needs with our selection of Turbidity Meter Accessories that include turbidity vials, primary turbidity standards, Formazin turbidity standards, and more.
Our turbidity meter has advanced features, including dual light sources and drinking water / wastewater methods approved.
Accessories for the turbidity meter include primary standards, Formazin turbidity standard, silicon oil and cloth kit, and replacement turbidity vials.
Keep pace with changing regulatory protocols; use the White Light LED to comply with EPA 180.1 requirements or Infrared (IR) LED to comply. Select from measure modes including EPA 180.1, Nephelometric, Absorbance, % transmittance, EBC and ASBC. This IP67 waterproof meter records 100 data points and offers an average battery life of 2500 hours intermittent use.
Auto-ranging from 0 to 1000 NTU (FNU)
Meets IP67 water-resistant requirements
Stores up to 200 sets of data
Suitable for field use.
Data-logging feature enables user to store up to 1,000 data sets with the date, time, and registration number.
Auto-ranging function automatically selects the correct range for turbidity measurement from 0.01 to 1100 NTU.
Instrument is power efficient; operates on seven NiCd rechargeable batteries (sold separately) or wall plug adapter.
The of turbidimeters offers simplistic operation combined with intelligent instrument engineering to provide an unparalleled level of accuracy in turbidity measurement.
Featuring the patent-pending sensor technology, the optical system is engineered with dual detectors to deliver a ratio reading which mitigates common measurement stability issues.
Reads up to 4000 NTU without the need for dilutions
Touchscreen interface for ease of operation
Supplied with AA
Superior data management - easily save and recall measurement data sets
Rechargeable battery pack accessory available
This user interface helps eliminates common frustrations and prevents errors. The data logging capabilities allow you to record the testing location, operator's identification, time and date along with the measurement. The intuitive, touchscreen interface makes it easy to perform procedures and interpret results. With function applications, you can navigate between settings and performing that function efficiently. Stored data can be transferred to a computer via USB.
For use with Portable Turbidimeters.
....Flocculation Testers (also known as Jar Testers) are designed for a range of applications - such as testing the efficiency of flocculation or precipitation agents
Digital display of stirring RPM.
Timer function.
Date and Time.
Illuminated back panel.
Height adjustment option for the stirring blades during operation.
Continuously variable stirring speed (lab versions only.)
Flocculation Testers (also known as Jar Testers) are designed for a range of applications - such as testing the efficiency of flocculation or precipitation agents
Illuminated back panel
Height adjustment option for the stirring blades during operation
Continuously variable stirring speed (lab versions only).
Digital display of stirring RPM
Timer function
Date and Time.
The rugged design makes this the instrument of choice for the toughest environments.
The Rapidly Settling Turbidity mode allows for accurate measurements even with the most difficult-to-measure settling samples.
With easy-to-follow on-screen instructions, manuals or memorization are not needed for routine calibrations.
Autorange from 0 to 1100 NTU with accuracy of ±2% of reading or ±0.01 NTU
Water-resistant, ABS-injection molded housing maintains laboratory performance in field operations
Resolution varies with turbidity range: 0.01 NTU for 0–99 NTU range, 0.1NTU for 100–999.9 NTU range, and 1 NTU for 1000–1100 NTU range
Light source: tungsten
Maximum sample size: 10mL
Other field-friendly features include push-button calibration, four-digit (seven-segment) LCD display, and long life—performs over 1000 tests on a single set of four “AAA” alkaline batteries
Response time: 14 seconds
Generate an accurate turbidity reading quickly with the 0 Turbidity Meter and its accessories. Perfect for the plant, field or lab, this simple yet powerful turbidity meter offers an impressive array of features.
This IP67 waterproof meter offers a long battery life averaging about 3000 tests.
Use the Infrared (IR) LED light source to comply and reliably measure turbidity with auto-ranging values from 0 to 1000 NTU.
The new laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding industrial and wastewater applications. Improved and intuitive design A smart device for more reliable measurements Easy to use. Easy to Be Right. Trusted measurement for high range turbidity applications; simplified.
A smart device for more reliable measurements
The ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.
Easy to use. Easy to Be Right
The provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, makes it easy to Be Right.
Improved and intuitive design
The large full colour touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.
For use with Lab Turbidimeter
....Save time and eliminate errors - no need for dilution
All concentrations of Turbidity Standards are verified to meet tight quality control specifications, for reporting purposes and guaranteed to save you time.
As a primary standard, Turbidity Standards can be used to calibrate or verify any turbidimeter.
EPA approved primary turbidity standard.
Long shelf life.
This 4-Pack of AA batteries is for use with various colorimeters, turbidimeters and other instruments.
....Save time and eliminate errors - no need for dilution
Long shelf life
EPA approved primary turbidity standard
As a primary standard, Turbidity Standards can be used to calibrate or verify any turbidimeter.
All concentrations of Turbidity Standards are verified to meet tight quality control specifications, for reporting purposes and guaranteed to save you time.
Consist of polymer microspheres suspended in a pure, aqueous medium
Uniform in particle size distribution to ensure consistent light scattering and precise enough to permit calibration down to and including 0 NTU
Primary turbidity standards for use in 90° nephelometers such as the 2100A, On-line instruments.
Ready to use — no mixing or dilution required
Nontoxic and won't settle out of suspension
Designed for 90° white light turbidimeters (EPA 180.1 design).
Guaranteed accuracy within 1%.
Reads up to 4000 NTU without the need for dilutions
Touchscreen interface for ease of operation
The Series of turbidimeters offers simplistic operation combined with intelligent instrument engineering to provide an unparalleled level of accuracy in turbidity measurement.
Superior data management - easily save and recall measurement data sets
Rechargeable battery pack accessory available
Supplied with AA
Featuring the patent-pending Multipath 90° sensor technology, the optical system is engineered with dual detectors to deliver a ratio reading which mitigates common measurement stability issues.
This user interface helps eliminates common frustrations and prevents errors. The data logging capabilities allow you to record the testing location, operator's identification, time and date along with the measurement. Stored data can be transferred to a computer via USB. The intuitive, touchscreen interface makes it easy to perform procedures and interpret results. With function applications, you can navigate between settings and performing that function efficiently.
For Use With (Equipment): Micro TPI and Micro TPW Portable Turbidimeters
Type: Primary Calibration Kit
Turbidity: 0.02, 10, 1000 NTU.
The auto-test ampoules contain a pre-measured amount of liquid reagent and easily fill with the correct volume of sample for simple and fast sample and reagent mixing. Each ampoule contains an Auto-ID barcode that is read by the colorimeter and used to automatically identify the test parameter and initiates the test. Minimize the risks of improper measurement and contamination with IV Chemistry Reagents, which are contained in self-filling vials. Use these reagents with the colorimeter to simplify sample preparation and tests.
No. of test: 30
Consistency and reproducibility improved with Aquafast ampoules and an meter
Eliminates measurement errors.
Equivalence Turbidity Standard is packaged in plastic case with a visual comparison card.
Polystyrene technology allows longer shelf life.
Tube size is 15 x 103mm and fits in most spectrophotometers.
The auto-test ampoules contain a pre-measured amount of liquid reagent and easily fill with the correct volume of sample for simple and fast sample and reagent mixing. Minimize the risks of improper measurement and contamination with IV Chemistry Reagents, which are contained in self-filling vials. Use these reagents with the colorimeter to simplify sample preparation and tests. Each ampoule contains an Auto-ID barcode that is read by the colorimeter and used to automatically identify the test parameter and initiates the test.
Consistency and reproducibility improved with ampoules and an meter.
No. of test: 30
Trusted measurement for high turbidity applications; simplified. Improved and intuitive design A smart device for more reliable measurements Easy to use. Easy to Be Right. The new laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding wastewater and industrial applications.
A smart device for more reliable measurements
The ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.
Easy to use. Easy to Be Right
The provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, it easy to Be Right.
Improved and intuitive design
The large full colour touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.
For Use With (Equipment): Turbidity Meter
Replacement cuvettes
Type: Cuvette
All concentrations of Turbidity Standards are verified to meet tight quality control specifications, for reporting purposes and guaranteed to save you time. As a primary standard, Turbidity Standards can be used to calibrate or verify any turbidimeter.
EPA approved primary turbidity standard
Save time and eliminate errors - no need for dilution
Long shelf life.
The Vial Cleaning Brush is designed to clean the inside of a sample cell without scratching or damaging glass.
....Replacement for Measurement Chamber Lid of turbidimeters.
For Use With (Equipment): Turbidimeter.
Type: Chamber Lid
Instrument-specific standards consisting of patented, polymer microspheres suspended in a pure, aqueous medium
Designed for 90° white light turbidimeters, except where noted.
Nontoxic and won't settle out of suspension
Accuracy within 1%
Ready to use — pour right from the bottle into sample cuvets.
Uniform in particle size distribution to ensure consistent light scattering and precise enough to permit calibration down to and including 0–1 NTU.
Supplied in ready-to-use sealed vials
Save time and eliminate errors - no need for dilution
All concentrations are verified to meet tight quality control specifications, are EPA compliant for reporting purposes and are guaranteed to save time.
Turbidity Standards are stabilized Formazin standards prepared in ready-to-use concentrations to ensure accurate turbidity measurements.
This Power Supply Set includes an External Wall Mount with input plug set and a USB A to USB C cable. For use with turbidimeters.
For Use With (Equipment): Turbidimeter.
Type: Power Supply
GFS Chemicals Linear Calibration SetsHighly accurate, stable and reproducible standards for calibrating turbidimeters and nephelometers.
Designed for 90° white light turbidimeters.
Ready to use — no mixing or dilution required
Nontoxic and won't settle out of suspension
Guaranteed accuracy within 1%
Consist of polymer microspheres suspended in a pure, aqueous medium
Uniform in particle size distribution to ensure consistent light scattering and precise enough to permit calibration down to and including 0 NTU.
The Standard Set A, delivers all the concentrations needed to calibrate and verify the Portable Turbidimeter.
Save time and eliminate errors - no need for dilution
The standards are supplied in sealed vials, eliminating the need for preparation, and ensuring safe operation.
Turbidity Standards are stabilized Formazin standards prepared in ready-to-use concentrations to ensure accurate turbidity measurements.
Supplied in ready-to-use sealed vials
EPA approved as primary calibration standards
All concentrations are verified to meet tight quality control specifications, are EPA compliant for reporting purposes and are guaranteed to save time.
Turbidity Standards are stabilized standards prepared in ready-to-use concentrations to ensure accurate turbidity measurements.
Save time and eliminate errors - no need for dilution
EPA approved primary turbidity standard
Eliminate the opportunity for inaccurate turbidimeter calibrations resulting from the improper dilution or handling of stock solution.
Long shelf life
As a primary standard, Turbidity Standards can be used to calibrate or verify any manufacturer's turbidimeter.
All concentrations of Turbidity Standards are verified to meet tight quality control specifications, are EPA and ISO compliant for reporting purposes and guaranteed to save you time.
Turbidity Standards are stabilized standards prepared in ready-to-use concentrations to ensure accurate turbidity measurements.
EPA approved primary turbidity standard
Long shelf life.
Eliminate the opportunity for inaccurate turbidimeter calibrations resulting from the improper dilution or handling of stock solution.
Save time and eliminate errors - no need for dilution.
Silicone oil can be used to prepare sample cells for turbidity measurement.
This Silicone Oil is for glassware preparation of turbidimeters.
The oil can be used to mask small scratches and other imperfections in the glassware.
Type: Chamber Lid
For Use With (Equipment): Turbidimeter
Replacement for Measurement Chamber Lid of turbidimeters.
Type: Battery Compartment Cover
For Use With (Equipment): Turbidimeter.
Replacement for Battery Compartment Cover of turbidimeters.
Sample cell for use with turbidimeters.
Includes lids
12 per pack.
The bottom insert which holds the turbidimeter and key accessories is made of 100% recycled ABS plastic, and can be recycled in the event it becomes damaged and is no longer usable.
This set replaces the Carrying Case, upper foam insert and lower tray insert for use with all versions of the turbidimeters. Pieces are not available separately.
The case features an easy to grip handle, and the integrated hinges make it robust and field-ready.
Replacement for USB connection Cover (Plug) of turbidimeters.
For Use With (Equipment): Turbidimeter.
Type: USB Cover
This Vial Stand offers space for six round cuvettes with a diameter of 24 mm
While in the stand, the vials are safely stored and cannot slip or tip over - it's the perfect assistant for smooth test procedures!
Thanks to the transparent acrylic, users always have an unobstructed view of sample development and color changes.
A standard industry USB-C Cable that is able to deliver power to the portable turbidimeters when combined with a power supply.
For Use With (Application): Alternate power supply option for turbidimeters.
For Use With (Equipment): Portable Turbidimeter.
Type: USB-C Cable
Length (Metric): 1 m
Precise, Pre-mixed Formazin Solutions. Based on Formazin Primary Standards. Enhanced Stability Saves Time and Labor. Confidence in results.
Stablcal calibration set with RFID, Laser Turbidimeter.
Multi-detector optical configuration assures long-term stability and minimizes stray light and color interference.
Easy menu driven operation and large LCD display
Advanced calibration algorithms.
Ideally suited for low-level drinking water applications, mid-range industrial applications, and high-range environmental applications.
500 point data log; stored results can be viewed directly on instrument.
Hard-tempered glass surface resists surface scratching
Reusable 28 × 70mm glass cuvettes
Cuvette stand stores up to 11 cuvettes or calibration standards.
Supplied with threaded light shield caps.
Preservative used enhances stability
Biodegradable, safe and non-toxic
Pre-diluted
Do not include formazin
Ready and easy to use
Type: Turbidity Standard
Volume (Metric): 100 mL.
Standards not harmful to the environment or to worker safety
Preservative used enhances stability
Biodegradable, safe and non-toxic
Pre-diluted
Do not include formazin
Ready and easy to use.
Densitometer is a compact device that can be used to measure turbidity (in the range of 0.5 to 4.0 McFarland units) of cell suspensions in a variety of life science applications.
This is ideal for determining concentration of cells for fermentation process, detecting the susceptibility of micro-organisms to antibiotics, identifying micro-organisms with various test systems, and measuring optical density at fixed wavelength.
This product features a measurement time of 1 second, a precision of 3%, and small footprint and low-profile design.
For calibration of turbidity meters. Includes one each of 60-mL HPDE bottle of four NTU standards.
....Clear turbidity standards are recognized by the primary stnadard for the calibration of turbidity meters online and in the laboratory for drinking water analysis.
Clear turbidity standards are traceable to NIST Primary Standards on account of their consistent particle size and photometric accuracy via UV-VIS spectroscopy.
Each lot is normalized to historical lots which were formulated to dilutions of 4000 NTU Formazin.
The densitometers are designed and factory calibrated to measure turbidity in the range of 0.5 to 4.0 units 0.0 to >7.5 units with a small standard deviation.
A compact benchtop densitometer (suspension turbidity meter) for measuring turbidity of cell suspensions in a variety of life science applications.
If required, it can deliver a wider measurement range (up to 15.00 units), but with a greater standard deviation.
Measurement time: 1 second. Precision: ±3%.
Measurement range: 0.5 to 4.0 units, 0.0 to >7.5 units.
Single use UV flow cell, 2mm path length, non-sterile, polysulfone, 1/8" inch hose barb.
....Highly accurate, stable and reproducible standards for calibrating turbidimeters and nephelometers.
....Single Use Turbidity Sensor, 6.5cm path length, non-sterile, polysulfone, 3/4 inch Sanitary Flange Inlet/Outlet.
....Use such replacement parts, accessories and reagents to keep your colorimeter and results dependable.
....Life Science Turbidity Standard, 126 NTU, 1 gallon.
....Clear turbidity standards are recognized by the EPA as a primary standard for the calibration of turbitidy meters online and in the laboratory for drinking water analysis.
Clear turbidity standards are traceable to NIST Primary Standards on account of their consistent particle size and photometric accuracy via UV-VIS spectroscopy.
Each lot is normalized to historical lots which were formulated to dilutions of 4000 NTU Formazin.
Replacement test tubes for use in Turbidity Meters
Sample vial for turbidity measurements, 10 mL line.
Fill the tube with water and drain it slowly by limiting flow with the pinch clamp on the hose
Stop draining once the black and white Secchi disk on the bottom of the tube becomes visible
GSC Turbidity Tube measures the cloudiness of a fluid
Take note of the water level using the centimeter graduations on the tube.
For 2020we and 2020wi Turbidity Meters
For Use With (Application): Compact handheld water analysis instrument with microprocessor driven optical system and unique optics configuration
Type: Test Tube
Includes: Screw-on cap
Material: Glass
For use with Portable Turbidity Meters
Packaged in 60mL bottles
Description: Turbidity Standard, 10 FNU/FNRU, 60 mL
Volume (English): 2 oz.
This Turbidity Standard is a calibration solution.
Type: Turbidity Standard
Packaging Type: Bottle
Description: Turbidity Standard, 1 NTU/NTRU, 60 mL
Volume (English): 2 oz.
This Turbidity Standard is a calibration solution.
Type: Turbidity Standard
Packaging Type: Bottle
Description: Turbidity Standard, 10 NTU/NTRU, 60 mL
Volume (English): 2 oz.
This Turbidity Standard is a calibration solution.
Type: Turbidity Standard
Packaging Type: Bottle
Compact handheld water analysis instrument with microprocessor-driven optical system and unique optics configuration.
Provides precise, sensitive and dependable measurements
Features seven languages, data logging (4000 points), signal averaging, USB port
Uses 3.7V lithium rechargeable battery and wall plug, with auto shut-off
Replacement glass test tubes available
Reads low levels for turbidity (0.05 NTU) and expands to higher ranges: 0-4000
Response time: <5 seconds.
Waterproof and dustproof with IP67 rated housing that floats
Portable and durable
Light weight
Four-point, push button calibration for full-range accuracy
For use in field testing and quality control
Repeatability and accuracy
Resolution as low as 0.01 NTU
Auto-ranging from 0 to 1000 NTU.
Ideal for regulatory monitoring, process control or field use.
For fast and easy turbidity measurement in both the field or in the laboratory
Large easy-to-read LCD screen
Easy calibration using supplied turbidity standards
Auto-ranging features selects the proper turbidity range for your sample
Simple five-key operation
Sample size: 10-15mL
Power efficient microcircuit design yields 5000 tests on four “AA” alkaline batteries with an estimated 7-10 year bulb life.
For use with Portable Turbidity Meters
Packaged in 60mL bottles.
Standards not harmful to the environment or to worker safety
Preservative used enhances stability
Biodegradable, safe and non-toxic
Pre-diluted
Do not include formazin
Ready and easy to use.
The large custom LCD displays reading and units of measure. Other features include auto-off, diagnostic error messages, and auto-ranging function.
Turbidity meter is easy to calibrate — meter automatically prompts you to the next calibration standard.
Sealed optical system with infrared light source delivers high accuracy across entire range.
Power saving function lets you take over 1000 readings on a single set of AAA batteries.
Turbidity standards are accepted for calibration purposes.
These standards are safe to handle in the lab. No special glassware or difficult lab techniques are required for the tests.
The pre mixed stabilized Formazin turbidity standards are true Formazin dilutions developed for use in any turbidimeter.
Its enhanced stability saves time and labor.; Platform: Solution; Parameter: ; Concentration: 1000 NTU; Precise, Pre-mixed Formazin Solutions; Enhanced Stability Saves Time and Labor; Confidence in results
standards have precise concentrations as low as 0.060 NTU for conventional turbidimeters.
Light Source: Infrared LED
Automatic Range Selection: Yes
Calibration Type: User calibration
Key Functions: Turbidity
Sample Size: 10 mL
Resolution: 0 to 10.99, 0.01; 11 to 109.9, 0.1; 110 to 1000, 1
Length (Metric): 178 mm
Width (Metric): 89 mm
Height (Metric): 65 mm
For Use With (Application): Natural waters, storm water
Accuracy: Three measurement modes: Ratiometric 0 to 2.5 FNU, ±0.05; 2.5-100FNU, ±2%; 100 to 1000FNRU, ±3%; Nephoelometric 0 to 2.5 FTU ± 0.05, 2.5 to 100FNU 0.1; Attenuation 0 to 2000 AU ±10AU
Battery Type: Lithium ion rechargeable
Voltage: 5 V
Temperature (Metric) Operating: 0°C to 50°C
Method: Ratiometric
Auto Shut Down Time: Disabled: 5 seconds, 10 seconds, 30 seconds
IP Rating: IP67
Weight (Metric): 368 g
Display Type: Backlit LCD
Includes: Carrying case; 0, 10, 100 FNU standards; sample bottles; USB cable; wall adapter; six sample tubes
Precision: 0 to 10.99, 0.01; 11 to 109.9, 0.1; 110 to 1000, 1.
For regulatory monitoring, process water testing, and environmental analysis in the field or laboratory.
Readings are determined by signal averaging to minimize fluctuations and have highly repeatable measurements
Simple calibration procedure with microprocessor adjusting calibration curve accordingly
USB port interfaces with a datalogger or computer; cable included.
Multi-detector optical configuration assures stability and minimizes stray light and color interferences.
Auto-Range: 0 to 4000 NTU
Accuracy: ±2%; ±3% over 100NTU
LCD Display: 6 lines with backlit display
Light Source: Tungsten filament lamp
Readout: 0.01 from 0 to 10.99; 0.1 from 11 to 109.9; 1 from 110 to 4000 NTU
Response Time: 5 sec.
Sample Chamber: Accepts 25mm diameter flat-bottom, screw-capped sample tubes
L x W x H: 7.5 x 3.5 x 2.5 in. (19.1 x 8.8 x 6.4cm).
Description: Turbidity Standard, 100 FNU/FBRU, 60 mL
For use with Turbidity Meter, Infrared Version
Volume (English): 2 oz.
Volume (Metric): 60 mL
Turbidity: 100 FNU/FNRU Standard
Compact handheld water analysis instrument with microprocessor-driven optical system and unique optics configuration.
Features seven languages, data logging (4000 points), signal averaging, USB port
Response time: <5 seconds
Provides precise, sensitive and dependable measurements
Reads low levels for turbidity (0.05 NTU) and expands to higher ranges: 0-4000
Uses 3.7V lithium rechargeable battery and wall plug, with auto shut-off
Replacement glass test tubes available.