Lab Tender Suppliers Africa and Lab Equipment Africa Kenya, Uganda, Sudan, Algeria, Morocco, Angola, Ghana, Mozambique, Madagascar, South Africa, Ivory Coast, Cameroon, Niger, Burkina Faso, Mayotte, Sao Tome, Seychelles, Zambia, Chad, Somalia, Senegal, Zimbabwe, Guinea, Rwanda, Benin, Burundi, Tunisia, South Sudan, Mali, Malawi, Nigeria, Ethiopia, Egypt, DR Congo, Tanzania, Togo, Sierra Leone, Libya, Congo, Central African Republic, Liberia, Mauritania, Eritrea, Gambia, Botswana, Namibia, Gabon, Lesotho, Guinea Bissau, Equatorial Guinea, Mauritius, Eswatini, Djibouti, Reunion, Comoros, Cape Verde, Western Sahara
Used to clean the optical lens of a HemoCue photometer series by absorbing dirty, dust or blood stains.
Material: Sponge made of polyvinyl acetate, pre-moistened with a cleaning solution.
Cleaner made of a lint and fiber-free material, highly absorbent.
Moistened with a cleaning solution; a soaked sponge with specific shape, mounted on a plastic holder.
Pack of 5 cleaners, each cleaner individually packed in a welded aluminum foil.
Single-use, sample collection and measuring microcuvette.
Capillary, venous and arterial whole blood can be used.
Collects 5 to 10uL capillary whole blood directly from the skin surface by capillarity.
Box of 100 microcuvettes , in plastic vial, with screw cap.
Inserted for direct reading into S0000590, Photometer,HemoCue glucose 201+/set.
Supplied with instruction manual in English, French, Spanish.
Multi-wavelength photometric measurement at chemical reaction end-point (667 nm - maxi absorbance point, and 840 nm - turbidity compensation).
Provides direct reading from inserted micro-cuvette.
Automated point-of-care device for measuring glucose in capillary whole blood.
Technology: optical absorption and reflectance photometry.
Sample size: 5 to 10uL capillary, venous or arterial whole blood.
Sample collected directly from skin surface into single-use microcuvette by capillary action.
Uses dedicated microcuvette (closed system).
Removable microcuvette holder to allow for easy cleaning.
Correlation with reference laboratory measurements: 0.99
Factory calibrated and continuous built-in auto self-test (when switched on). Needs no further calibration.
Measuring range: 0 to 500 mg/dL.
Read-out in: mg/dL or mmol/L.
Reading time: 40 sec. to 4 min.
Interfaces: RS 232 to printer or computer.
Power supply: 220V /50 or 4 x type AA / R6 1.5 V batteries (allowing for 100h to 150h continued usage).
Display informs: glucose reading, reading errors, systems errors, battery status.
Symbols in display facilitate multi-lingual understanding.
Built-in memory, storing > 400 measurements.
Supplier’s product reference: HemoCue Glucose 201+ analyzer starter set/kit.
Sample size: 5 to 10uL capillary, venous or arterial whole blood.
Sample collected directly from skin surface into single-use micro-cuvette by capillary action.
Uses dedicated micro-cuvette (closed system).
Measuring range: 0 to 26 g/dL.
Read-out in: g/dL or mmol/L
Reading time: <20 sec.
Display informs: haemoglobin reading, reading errors, systems errors, battery status.
Automated point-of-care device for measuring haemoglobin in capillary whole blood
Technology: Dual wave length optical absorption photometry (506 nm and 880 nm for Hb measurement and turbidity compensation).
Both wave lengths are at isobestic points for oxyhaemoglobin and deoxyhaemoglobin
Calibrated and built-in auto self test each time the device is switched on. Needs no further calibration.
Provides direct reading from inserted micro-cuvette.
Removable micro-cuvette holder to allow for easy cleaning
Accuracy: Correlation with the ICSH (International Committee for Standardisation in Haematology) reference method: 0.99
Symbols in display facilitate multi-lingual understanding
Interfaces: RS 232 to printer or computer.
Power supply: 220V /50 or 4 x type AA / R6 1.5 V batteries (allowing for 100h to 150h continued usage).
Capillary, venous and arterial whole blood can be used.
Inserted for direct reading into S0000591, Photometer,HemoCue Hb 301/set.
Microcuvette is made of polystyrene plastic, contains pre-applied, dried reagents.
Single-use, sample collection and measuring microcuvette.
Collects 10 to 12uL capillary whole blood directly from the skin surface by capillarity
Box of 200 microcuvettes, 4x50, in a plastic vial, with screw cap.
Supplied with instruction manual in English, French, Spanish.
Supplier’s product reference: HemoCue Hb 301 Microcuvettes.