Vortex Tube Refrigerator Apparatus From compressed air at ambient temperature and a high speed rotating vortex, the unit produces air temperatures down to -20Â °C, can perform 75 watts of cooling and discharges a hot air stream at up to 70Â °C.
The Vortex Tube Refrigerator Apparatus is a fully instrumented bench top Vortex Tube Refrigerator Apparatus having no moving parts and requiring only a compressed air or other suitable gas supply to operate.
The hermetically sealed refrigerant compressor incorporates a brushless three phase DC electric motor that is driven by a variable speed controller. Compressor speed and power supplied is displayed on the PC.
The condenser and evaporator are brazed plate heat exchanger and utilize a large common reservoir of water to minimize changes in water temperature during operation. The refrigerant exiting the compressor passes through a condenser, receiver, filter, variable area flow meter, expansion valve and evaporator before retuning to the inlet side of the compressor.
Freezer and Refrigerator
....Vaccine storage capacity: 36 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 60 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Vaccine storage capacity: 70 L
Volume category: >/=60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 85 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
The Fridge Tag 2E, with internal sensor, is an electronic 30-Day Temperature Recorder (30DTR) with factory-programmed alarms and visual display for monitoring storage conditions in vaccine refrigerators (+2°C to +8°C) over a 30-day period. The Fridge Tag 2E has a USB interface and can be connected to a PC or Mac without any installation software. When connected, the Fridge Tag 2E will automatically generate a 60-day report in PDF and ASCII file formats, which includes all relevant information per day such as min/max and average temperatures, time out of range, alarm history etc. The device shows the actual temperature, all alarm violations over the previous 30 days (on a rolling basis), the daily minimum and maximum temperature of the last 30 days, and the time duration of any violation.
....Laboratory Upright Refrigerator, Low Temperature Range
....The solar energy is captured by a cylindrical parabolic solar concentrator in which the parabola axis is constituted by a high thermal conductivity tube and black colour containing an adequate liquid able to capture the solar energy increasing its temperature. The Computerized Educational Equipment On The Thermal Solar Refrigeration Cycle is one of the most interesting applications of solar thermal energy because it is able to use the solar energy and, via an absorption cycle, to convert the energy in a source of cold that can be used for food conservation chain, air conditioning, chilling water and in general in all the applications of refrigeration and conditioning purposes without the use of electrical energy. The Computerized Educational Equipment On The Thermal Solar Refrigeration Cycle has been designed and manufactured by Italia to allow the experimental study of an absorption refrigeration plant using solar energy as energy source. Owing the peculiarity of the plant able to use the solar energy to convert it in a source of cold, the plant is particularly interesting in all the countries of the equatorial area, where the sun is the main energy source and the coverage of the electrical network is scarce.
....Vaccine storage capacity: 72.5 L
Refrigerant: R600a, 45 grams
Volume category: >/= 60, <120L
Energy consumption, stable running (kWh/24 hours): 1.47
Equipment operating voltage and frequency: 220-240 Volt, 50Hz/60Hz or 100-127 Volt 50Hz/60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10 C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Vaccine storage capacity: 57 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 100 grams
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Commercial Refrigeration Training Unit the powder coated evaporator is a forced air, blow through type with removable front panel and galvanised sheet steel casing. Commercial Refrigeration Training Unit consists of an air cooled condensing unit with high back pressure, high starting torque hermetic compressor, Complete with: Suction and Discharge Service Valves; Gauge Manifold Connections and Built in Motor Protector. The evaporator is a finned coil type with fins a 5 fins per inch.
Commercial Refrigeration Training Unit unit may be thermally loaded for performance investigation and has a dial thermometer; Liquid Line Filter Drier; Liquid-vapour Heat Exchanger; High Pressure Switch; Low Pressure Switch; Internally equalised Thermostatic Expansion Valve; High Pressure gauge; Low pressure Compound gauge.
Vaccine storage capacity: 225 L
Volume category: >120L
Refrigerant: R600a, 68 grams
Energy consumption, stable running (kWh/24 hours): 2.04
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Operating temperature: Min and Max rated ambient temperature:+10 C and +43°C
UIFPF- Grade A
Equipment operating voltage and frequency: 220-240 Volt, 50Hz/60Hz or 100-127 Volt 50Hz/60Hz, 1ph.
Vaccine storage capacity: 102 L
Volume category: >/= 60, <120L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 100 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
The Trainer On Domestic Refrigerators With One Evaporator And Hermetic Compressor allows to study the circuit layout adopted in the normal domestic one-compartment refrigerator systems, fitted with positive temperature evaporator and hermetic compressor. The training unit is supplied as standard with a full set of manuals describing the composition of the unit, the set up procedure, operating methods and some exercises. The refrigerator circuit is made of copper pipes. The set of equipment and the vacuum and recharge station allow a fast assembly and disassembly of the refrigerator circuit. A wheeled frame carries a horizontal working panel, fitted with a 80 mm vice, and a vertical frame, where the main components of the unit and a silk-screen printed synoptic panel are mounted at sight. The student can rise his knowledge about the main components of a refrigerator plant, experiment the problems due to the filling and the emptying of the circuit and, at last, simulate some simple faults.
....A dedicated Hermetic Refrigeration Training Unit with a capillary flow control and a range of switch activated faults for student practice.
The unit includes: Fan cooled Hermetic Refrigeration Training Unit condensing unit with high starting torque compressor; Front mounted evaporator with suction accumulator; Liquid line dryer; Compound and Pressure gauges
Using the push button switches, five system faults can be introduced into the system: Faulty compressor valve; Choked capillary; Excess discharge pressure; Overcharged system; Undercharged system.
Vaccine storage capacity: 51 L
Volume category: <60L
Refrigerant: R600a, 45 grams
Energy consumption, stable running (kWh/24 hours): 1.63
Equipment operating voltage and frequency: 220-240 Volt, or 100-127 Volt and frequency 50Hz or 60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Volume category: <60L
Vaccine storage capacity: 37.5L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 90 grams
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Visual Refrigeration Training Unit operates on refrigerant. An electrical control box is mounted on the back panel and includes indicators/warning lamp, on/off contactor and overload, as well as residual current device for protection against earth leakage. Visual Refrigeration Training Unit comprise an air-cooled condensing unit with open type twin cylinder reciprocating compressor and a transparent plastic evaporator, clearly showing change of state of refrigerant from liquid to vapour phase. The unit also incorporates, Liquid/suction heat exchanger, Liquid line filter drier and sight glass, HP/LP switches, Compound and pressure gauges, Suction and discharge service valves fitted, Liquid line hand wheel valve fitted for easy manual pump down of system. The following refrigerant flow control options may be selected by the use of hand wheel valves: Automatic Expansion Valve; Thermostatic Expansion Valve, Internally equalised; Capillary with Separate Filter Drier.
....Vaccine storage capacity: 98.5 L
Volume category: >/= 60, <120L
Refrigerant: R600a, 45 grams
Energy consumption, stable running (kWh/24 hours): 1.23
Equipment operating voltage and frequency: 220-240 Volt, or 100-127 Volt and frequency 50Hz or 60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF- Grade A.
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Vaccine storage capacity: 100L
Volume category: >/= 60, <120L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 135 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.