Designed for blood sample collection, preserves nucleic acid in the dried blood spots for subsequent laboratory tests.
To collect and transport dry blood specimens for early infant diagnosis of HIV
Dry blood spot (DBS) absorbent filter paper.
Stability: Minimum 24 months for DNA.
DNA, DNase, RNase, & PCR inhibitor.
With 5 distinct pre-marked spots.
Spots are pre-perforated / pre-punched, facilitating processing in PCR applications.
Used for multiple tests.
Heparin coated internally
Capillary glass tube
Length approx. 75 mm
Diameter approx. 1.2 mm
Seal-packing of smaller units (such as 100 tubes).
Intended use:
Various general clinical laboratory usage conditions including sample preparation, separation, centrifugation, and cold storage.
Used for multiple tests.
EDTA coated internally.
Capillary glass tube.
Length approx. 75 mm.
Diameter approx. 1.2 mm.
Intended use:
Various general clinical laboratory usage conditions including; sample preparation, separation, centrifugation, and cold storage.
Blood collection for clinical laboratory tests.
Blood collection vacuum tube.
Material: clear non-fragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Capped, with needle pierceable vacuum seal.
Additive EDTA anticoagulant
Standard color-coded cap.
Applicable for automated analysers.
Sterile.
Blood draw volume 2.0ml.
Pen/Marker writable label space.
Blood collection for clinical laboratory tests.
Capped, with a needle-pierceable vacuum seal.
Blood collection vacuum tube.
Material: clear nonfragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Applicable for automated analyzers.
Pen/Marker writable label space.
Blood draw volume 4.0ml.
Additive EDTA anticoagulant.
Standard color-coded cap.
Blood collection vacuum tube.
Material: clear nonfragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Sterile.
Blood draw volume 6.0ml.
Capped, with needle-pierceable vacuum seal cap.
Applicable for automated analyzers.
Pen/Marker writable label space.
Additive EDTA anticoagulant.
Standard color-coded cap.
Serum collection for clinical laboratory tests.
Blood draw volume 3.5ml.
Material: clear nonfragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Blood collection vacuum tube.
Capped, with needle-pierceable vacuum seal cap.
Additive; Serum separation gel with clot activator.
Pen/Marker writable label space.
Standard color-coded cap.
Blood collection vacuum tube.
Blood draw volume 6.0ml.
Material: clear nonfragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Capped, with needle-pierceable vacuum seal cap.
Standard color-coded cap.
Pen/Marker writable label space.
Additive; Serum separation gel with clot activator.
Intended use:
Microscope slide for use with standard transmitted light microscope. For clinical laboratory use.
Serum collection for clinical laboratory tests
Blood collection vacuum tube
Blood draw volume 4.0ml
Material: clear nonfragile PET plastic and leak-proof rubber cap
Plastic shielded rubber cap to protect personnel from direct contact with blood
Capped, with needle pierceable vacuum seal cap
Sterile
Plain/dry, No additive
Pen/Marker writable label space.
Intended use:
Microscope slide for use with standard transmitted light microscope. For clinical laboratory use.
Serum collection for clinical laboratory tests.
Blood collection vacuum tube.
Blood draw volume 6.0ml.
Material: clear nonfragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Capped, with needle-pierceable vacuum seal cap.
Plain/dry, No additive.
Pen/Marker writable label space.
Standard color-coded cap.
Intended use:
Used as cover glass for microscope slides in standard transmitted light microscopy. For clinical laboratory use.
Blood collection needle for use with vacuum tubes. For use in clinical phlebotomy.
Blood collection needle.
Sterile, individually packed in a twist-apart plastic container.
Material; Medical grade stainless steel.
Length approx. 40 mm
Diameter 20 G (0.9 mm)
Applicable for multi-sample draw.
Needle fits (screw in and out) needle holder.
Pointed at both ends, with rubber sleeve on the posterior end needle.
Applicable for multi-sample draw
Needle fits (screw in and out) needle holder
Sterile, individually packed in a twist-apart plastic container
Blood collection needle for use with vacuum tubes. For use in clinical phlebotomy.
Material; Medical grade stainless steel
Blood collection needle
Pointed at both ends, with rubber sleeve on the posterior end needle.
Length 25 mm
Diameter 22 G (0.72 mm)
Blood collection needle holder for use with vacuum tubes, and vacuum tube needles.
For use in clinical phlebotomy.
Material; clear polypropylene plastic
Fits all standard, 13mm, and 16mm diameter vacuum tubes, and all common needle units.
Disposable
Blood collection needle holder.
Used for various clinical and laboratory purposes.
Tube material: Polypropylene.
Plastic handle stick.
Sterile, individually packed in a tube.
Rayon/cotton tipped.
Length:12cm.
Capacity Approx. 50ml.
Non-sterile, Single use/disposable.
Screw cap, wide mouth, leakproof.
Clear plastic.
Sample container used to collect a wide range of clinical specimens.