Material: Needle: Stainless steel conform to ISO 9626-1:1991.
Measurements: External diameter expressed in Gauge and millimetres.
Base and protective cap: medical grade plastic.
Length expressed in inch and millimetres.
Sterile
Disposable.
Size selected: 23Gx1” (0.6x25mm).
Compression testing machines 3000 KN motorized with control unit fully automatic model high stability, to test blocks max. 500x300 mm, cubes up to 200 mm side and cylinders up to dia. 160x320 mm.
....Compression testing machine 3000 KN motorized 2 gauges to test blocks max. 500x300 mm, cubes up to 300 mm side and cylinders up to dia. 160x320 mm
....Compression machine 3000 KN motorized with control unit, to test blocks max. 500x300 mm, cubes up to 300 mm side and cylinders up to dia. 160x320 mm
....Compression machine 3000 KN motorized 1 gauge to test cubes up to 200 mm side and cylinders up to dia. 160x320 mm.
....Intended use: Solely for the subcutaneous single-use injection of insulin only in humans, with which the syringes are filled by the end user and used immediately after filling. Syringes are not intended to contain insulin for extended periods of time
Insulin Syringe, 1ml, U-100, three pieces: barrel with nozzle, stopper and piston/plunger with stainless steel fine needle and a needle orange cap.
Blister packed.
Compression machine 3000 kN, motorized with control unit, to test cubes up to 200 mm side and cylinders up to dia. 160x320 mm.
....Compression testing machines 3000 KN motorized with control unit semi-automatic model, high stability, to test cubes up to 200 mm side and cylinders up to dia. 160x320 mm.
....Compression machine 3000 KN high stability, motorized, with control unit to test blocks max. 500x300 mm, cubes up to 200 mm side and cylinders up to dia. 160x320 mm.
....Heavy duty boots (Wellington boots)
Material: Shaft and outsole: PVC
Lining: Polyester fiber facilitates slide-in and removal
Waterproof
Reusable
Oil- and fuel oil resistant
Size: 43 (EU)
Length shaft: approx. 38 cm
Color: Sole: green or black
Color: Shaft: white or green
Disposable liquid-tight biohazard protective coverall, for use in EVD patient isolation units for infection prevention and control against viral penetration.
After use, the coverall is disposed in a biohazard waste container, collected and destroyed. This is also applicable if the coverall is damaged (perforation, etc.).
Disposable liquid-tight biohazard protective coverall, for use in EVD patient isolation units for infection prevention and control against viral penetration. After use, the coverall must be disposed in a biohazard waste container, collected and destroyed. This is also applicable if the coverall is damaged.
....Disposable liquid-tight biohazard protective coverall, for use in EVD patient isolation units for infection prevention and control against viral penetration. After use, the coverall must be disposed in a biohazard waste container, collected and destroyed. This is also applicable if the coverall is damaged.
....Diagnostic socket fitted for the connections of fault code readersor blink coding. The ABS trainer offers an enhanced training resource, hands ontraining with real components, greater understanding for the student withoutthe constraints of the modern motor vehicle. Self contained, fully operational ABS trainer, complete withfull braking circuit, manufactured using genuine car components. Simulation ofwheel lock to activate ABS modulator. Brake pedal kick-back can be observed. Fault panel to aid studentdiagnosis. Speed simulation 0-160 km/h. Pressuregauges show front and rear line pressures and individual pressure at eachwheel.
....The Air Conditioning trainer offers an enhanced training resource, hands-on training with real components, greater understanding for the student with out the constraints of the modern motor vehicle.
Self contained fully operational Air Conditioning Trainer.
Complete with compressor, condenser, receiver dryer, expansion valve and evaporator.
Supplied with sight glasses to observe the state of charge of the refrigerant in the high andlow pressure sides.
High and low pressure service ports, easily accessed for recovery and re-charging of there frigerant.
Fully portable unit easily transported for off-site training, complete with stand.
Component used represent a modern A/C circuit, environmentally friendly, using R134a refrigerant.
Including evaporator, compressor, condenser, associated pipe work, climatecontrol and electronic control.
Fullyoperational climate control trainer manufactured using original components.
The system is powered by a 12 V DC battery forthe electrical circuit and by 240 V AC for the speed controlled motor.
This product is intended for use exclusively by trained medical professionals. The ShangRing comes in a range of 24 sizes (from A4 to Z), each with a unique inside diameter that ranges from 11mm to 40mm. To provide a safe method of performing male circumcision in adolescent and adult populations with the primary goal of reducing the transmission of Human Immunodeficiency Virus (HIV), while also targeting the prevention of Human Papillomavirus (HPV), which is associated with cervical cancer and anal cancer, and Human Herpes Simplex Virus type 2 (HSV-2), which causes genital ulcers and increases the risk of acquiring HIV.
....This product is intended for use exclusively by trained medical professionals. The ShangRing comes in a range of 24 sizes (from A4 to Z), each with a unique inside diameter that ranges from 11mm to 40mm. To provide a safe method of performing male circumcision in adolescent and adult populations with the primary goal of reducing the transmission of Human Immunodeficiency Virus (HIV), while also targeting the prevention of Human Papillomavirus (HPV), which is associated with cervical cancer and anal cancer, and Human Herpes Simplex Virus type 2 (HSV-2), which causes genital ulcers and increases the risk of acquiring HIV.
....This product is intended for use exclusively by trained medical professionals. The ShangRing comes in a range of 24 sizes (from A4 to Z), each with a unique inside diameter that ranges from 11mm to 40mm. To provide a safe method of performing male circumcision in adolescent and adult populations with the primary goal of reducing the transmission of Human Immunodeficiency Virus (HIV), while also targeting the prevention of Human Papillomavirus (HPV), which is associated with cervical cancer and anal cancer, and Human Herpes Simplex Virus type 2 (HSV-2), which causes genital ulcers and increases the risk of acquiring HIV.
....