Set of 3 full colour posters, made of synthetic paper, printed in Arabic and with Braille printing/embossing.
....Standard specification for the Ambulance:
Main stretcher with caster
Room lamp, 1 pc
Attendant seat, 5 persons
Electric Siren Amplifier & Speaker, 1 tone
Fire extinguisher
Beacon lamp, red
Floor, plywood & linoleum covered floor.
Standard Equipment:
Air cleaner, cyclone type
Clock, built-in trip meter
Electrical system, 12V
Fire extinguisher, 1kg install
Front headrests, 3pcs for LHD, 2pcs for RHD
Air conditioner, front and rear (Non CFC)
Assist grips, front:3
Battery, 85D26Rx2(55AHx2)
Beacon lamp(red, front 55W)
Cigarette lighter
Head lamp, sculptured 2
Heater, front & rear
Inside rear view mirror, day and night
Intermittent wiper, intermittent
Front seat: 3persons
Front seat belt, 3P ELRx2 + NRx1
Front wheel brake, disc (15 inches)
Fuel lid opener, cable type
Plywood & linoleum covered floor
Power steering
Pre-air cleaner
Radio, AM/FM, w/ 2 sp.
Lockable fuel tank
Main stretcher w/ caster
Mud guards, w/o
Outside rear view mirror, 2pcs
Rear door inside handle
Rear seat, w/o
Rear wheel brake, drum
Room lamp(8W) : front + center + rear
Seat material, fabric
Steering wheel, 2-spoke urethane
Sub stretcher, folding
Sun visors, 2 pcs.
Suspension, fr:double wishborn, rr:rigid leaf
Tool kit with jack & Jack handle
Touch-up paint
Seats, attendant, folding type, 4 persons
Side door beam, front and slide door
Siren amplifier, electric & speaker (1 tone type)
Spare wheel, 1pc (full size)
Steering column, manual tilt
Towing eye, front and rear
Wheel cap, full cap
Wheel house cover
Towing hook, fr: 1
Transport hook, fr: 2
Triangle caution plate, 1pc loaded
Tyres: 195R15C 8PR Tubeless 15x6JJ
Windshield glass, green (adhesion).
The utility model is used for sampling water samples in water quality or water plankton for environmental protection and other relevant departments.
....Glue, water-based, such as PVA (Poly Vinyl Acetate)
Bottle is labeled with product information (i.e. ingredients), age suitability, directions for use, safety instructions.
For classroom use with paper or cardboard.
No organic solvents, non-toxic, non-flammable, washable.
Surgical gloves are sterile and strictly SINGLE USE. For surgical procedures or any sterile medical procedure to protect both patient and medical staff from cross-contamination.
....Vaccine carrier, Large, Long range
Vaccine storage capacity: 1.67 litres
With lid and shoulder strap.
Cold life at 43°C without openings: 35.7 hours
Supplied with 4 x 0.4L icepacks as a standard.
Weight fully loaded: 4.34 Kg.
Anatomically shaped: 1 right-handed, 1 left-handed
Material: Natural latex
Single-use
Sterile
Powder-free
Size: 7.5
Total length: approximately 270 mm
Width: approximately 95 +/- 5 mm
Chalkboard panel without frame, 1160 x 760 mm, highly pressed fibre board insulite type, smooth surface on both sides, 5 mm (+/-0.5 mm) thick, with rounded corners, finished in black special blackboard paint on both sides and all four edges; granularity suitable for white slate pencil and chalk, UV dried (environmental friendly), for easy cleaning with dry or wet cloth. Two 10mm diameter eyelets (holes) on the 1160 mm side to permit hanging and use of both sides.
....Vaccine storage capacity: 170 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 50 grams
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 1.7 litres
Vaccine carrier, Large, Long range
With lid and shoulder strap.
Cold life at +43°C without openings: 38 hours 37 minutes
Supplied with 4 x 0.4L icepacks as a standard.
Weight fully loaded: 3.34 Kg.
Used for aspirating fluids / secretions from the operative area.
Material: Austenitic steel (non-quenched, non-magnetic steel).
Austenitic steel composition: 16-18% chromium, 8-14% nickel, 2-3% molybdenum.
Curved.
Suction tube with removable tip and tubing connector.
Length: approx. 27 cm.
Diameter: approx. 6 mm or 8 mm.
Reusable.
Surgical dissecting scissors used for cutting tissue, threads and dressings.
Material: Martensitic steel (quenched, magnetic steel).
Martensitic steel composition: 0.15-0.40 % carbon; 13-14 % chromium.
Instrument that cuts by shearing: operating, dissecting scissors.
Curved, with blunt end blades.
Length: 17 cm.
Reusable.
Material: Austenitic steel (non-quenched, non-magnetic steel).
To dilate the vagina to examine the vaginal canal and cervix.
Speculum, vaginal, self-retaining.
Double blade with a screw mechanism to keep the blades open.
Austenitic steel composition: 16 - 18% chromium; 10 - 14% nickel; 2 - 3%molybdenum.
Blade length: approx. 75 mm.
Blade width: approx. 20 mm.
Reusable.
Endotracheal tube shall meet the standards concerning the dimension, the tube, the point, the cuff and the marking.
Endotracheal tube with:
Standard connector (ext. Ø 15mm) at the proximal end enabling the tube to be connected to the ventilation system.
Open distal end and Magill-type point with oral angle of 37.5º.
Cuff located near the distal end: Low pressure cuff, inflating system with valve and Luer tip connector.
Radio opaque mark.
With Murphy's eye.
Material: Polyvinyl chloride (PVC).
Sterile.
Disposable.
Graduations.
Size: Ø internal 7mm.
Initial sterilisation method: Ethylene oxide gas or Gamma radiation.
Endotracheal tube shall meet the standards concerning the dimension, the tube, the point, the cuff and the marking.
Open distal end and Magill-type point with oral angle of 37.5º.
Cuff located near the distal end: Low pressure cuff, inflating system with valve and Luer tip connector.
Endotracheal tube with:
Radio opaque mark.
With Murhpy's eye.
Graduations.
Standard connector (ext. Ø 15mm) at the proximal end enabling the tube to be connected to the ventilation system.
Material: Polyvinyl chloride (PVC).
Sterile.
Disposable.
Size: Ø internal 7.5mm.
Initial sterilisation method: Ethylene oxide gas or Gamma radiation.
The densitometers are designed and factory calibrated to measure turbidity in the range of 0.5 to 4.0 units 0.0 to >7.5 units with a small standard deviation.
A compact benchtop densitometer (suspension turbidity meter) for measuring turbidity of cell suspensions in a variety of life science applications.
If required, it can deliver a wider measurement range (up to 15.00 units), but with a greater standard deviation.
Measurement time: 1 second. Precision: ±3%.
Measurement range: 0.5 to 4.0 units, 0.0 to >7.5 units.
AC and DC Arc Welder 7.5KW
....Stretch bandage roll with clips.
Non-adhesive, unbleached colour and non detectable by X-ray.
Thread count:
Material: Crepe bandage produced by combining high twist cotton threads with normal twist cotton threads in warp. 100% cotton.
Weft: 54 threads/dm + or - 2 threads unbleached cotton.
Warp: 120 threads/dm, unbleached cotton, high-twist.
Size selected: Bandage elastic, roll
Length: Not stretched: +/- 3m. Stretched: +/- 5m (elasticity +/- 150 %).
Reusable.
Non-sterile.
Width: 7.5 – 8 cm
Flexible and durable light liquid splash protection
Elastic opening for tighter fit at ankle
Elastic opening for tighter fit at wrist
Attached hood with elastic around face opening
Yellow for high visibility
Polyethylene-coated fabric provides at least 30 minutes of protection against 42 chemical challenges
10 mil thickness.
This product is intended for use exclusively by trained medical professionals. The ShangRing comes in a range of 24 sizes (from A4 to Z), each with a unique inside diameter that ranges from 11mm to 40mm. To provide a safe method of performing male circumcision in adolescent and adult populations with the primary goal of reducing the transmission of Human Immunodeficiency Virus (HIV), while also targeting the prevention of Human Papillomavirus (HPV), which is associated with cervical cancer and anal cancer, and Human Herpes Simplex Virus type 2 (HSV-2), which causes genital ulcers and increases the risk of acquiring HIV.
....