Vaccine storage capacity: 99 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 76 grams
New Energy (Battery Energy Vehicle) Whole System Electronic Engineering Lab
....Vaccine storage capacity: 36 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 40 grams, R600a, 30 grams, R290, 10 grams.
Vaccine storage capacity: 220 L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 65 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
EV Traction Battery Pack Loading and Testing Training Platform Electronic Engineering Lab
....Vaccine storage capacity: 50 L
Volume category: <60L
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 150 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Vaccine storage capacity: 100L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 65 grams.
Vaccine storage capacity:200L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 65 grams.
Vaccine storage capacity: 80.5 L
Volume category: >/=60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 60 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 61.25 L
Volume category: >/=60, <120 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 50 grams, R600a, 30 grams, R290, 10 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 48 L
Volume category: <60 L
Ambient operating temperature: Min. +5°C, Max. +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R290, Refrigerator system: 55g/Freezer system: 45g.
Vaccine storage capacity: 120 L
Volume category: >/=120L
Autonomy time: Appliance’s autonomy at +43 ?C ambient: 82 hours 5 minutes
Refrigerant: R600a, 57 grams / Freezer: 47 grams
Operating temperature: +5 °C to +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Vaccine storage capacity: 110 L
Volume category: >/=60, <120 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 75 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 58 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF: Grade A
Refrigerant: R290a, 35 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Gros volume-Freezer: 34.3 L
Volume category: <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Max rated ambient temperature: +43°C
Refrigerant: R600a, 30 grams, R290a, 10 grams
PQS prequalified Solar direct drive water packs freezer with no battery for freezing of water packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Vaccine storage capacity: 55.5 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 50 grams.
Vaccine storage capacity: 92 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 50 grams.
Vaccine storage capacity: 170 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 50 grams
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Portable suction machine for airway aspiration, minor surgery, emergency, patient transfer, suitable for use in hospitals and at home.
The unit provides intermediate and continuous suction. Continuous is limited to 30 minutes after which the unit should be given 30 minutes to cool down.
The flow rate at maximum vacuum is ≥ 33 L/m (2 m³/h).
The unit is provided with a suction tube of at least 1.5 meters.
The suction tube is made of medical grade silicone which is autoclavable at 121°C.
During operating the unit's noise level does not exceed 65.5 dB.
The unit is designed in such a way that it requires little or no oil.
The pump is equipped with a provision preventing fluid flowing to the pump if the collection jar is full (overflow control valve).
The unit is provided with one (1) reusable collection jar.
The unit has maintenance free operating.
A gauge indicating the negative pressure generated by the unit.
A hydrophobic bacterial filter is included in the airline to the pump.
The user adjustable suction ranges between 0 and at least 525 mmHg (70 kPa).
The unit should be provided with a carrying handle and storage provisions for all accessories, allowing to carry the unit with one hand.
The body is to be constructed of stainless steel or material which is non-corrosive or has a corrosion resistant coating.
The unit is equipped with a lead-acid battery.
The battery should be able to power the unit for up to 60 min.
The design of the device should be such that it is easy to clean/disinfect by avoiding difficult-to-reach areas and having smooth surfaces.
The device should have a sturdy, shock resistant casing.
A visual alarm should be incorporated in the unit signalling depletion of the batteries.
The unit should be provided with a battery level indicator and a charging indicator.
The unit should be able to simultaneously operate and charge from 12 Volt as well as the main power grid.
Power requirements: 230 Volts - 50Hz
The weight of the unit does not exceed 5.5 kg.