The trainer features a fully functioning Automatic Transaxle Trainer that can be manually shifted through all foreword and reverse gears. It features the popular Automatic Transaxle found on most chrysler front wheel drive cars. The Automatic Transaxle Trainer is designed to assist in educating the fundamentals of a front drive transaxle. The package includes a complete compentency based training program which instructs the student from basic operation and adjustment to complete overhaul of the transmission.
....Training Objectives:
Operating the wind turbine and the anemometer
Braking in the braking mode
Braking in the no load operation/open circuit/free spinning mode
Identification of the components
Installation and testing of the anemometer
Installation and testing of the wind turbine
Battery regulating and charging
Supplying AC load with wind power and a battery
Direct current wind energy installation
Supplying AC load with wind power stored in a battery
Complete system for wind energy.
The stiffness of a spiral spring depends on its physical dimensions and the rigidity of the steel strip from which it is formed. With the Torsion of Spiral Spring Apparatus student can easily calculate the theoretical stiffness of the spring, and compare the value with simple experimental results. Spiral springs are used to provide a resisting or restoring torque to a shaft when it is rotated through an angular displacement. One end of the spring is attached to a shaft mounted in ball bearings. A load hanger and calibrated weights is used to incrementally load the spring. They exhibit similar stiffness characteristics to linear springs, except that the effect is one of torque rather than force. The wall mounted unit consists of a spiral spring coiled from a length of steel strip. Spring deflection is measured with an attached scale.
....Intended use:
Intended for molecular medical laboratory, PCR work. Micropipette tips for use with standard Micropipettes used for pipetting small amounts of liquid in the laboratory.
Used for capillary blood collection
In-built mechanism to retract needle tip preventing reuse or injury.
Instant trigger launches spring-based blade.
Sterile, disposable.
Blade depth approx. 2.0mm.
Vaccine carrier, Extra Large, Long range
Vaccine storage capacity: 2.7 litres
With lid and shoulder strap.
Cold life at 43°C without openings: 46 hours 23 minutes
Supplied with 4 x 0.6L icepacks as a standard.
Weight fully loaded: 6.4 Kg
Gross volume-Freezer: 265L
Volume category: >150L
Refrigerant: R600a, 80 grams
Energy consumption, stable running (kWh/24 hours): 1.43
Equipment operating voltage and frequency: 220-240 Volt, and frequency 50Hz /60Hz, 1ph.
Operating temperature: Max rated ambient temperature: +43°C
PQS Prequalified Mains Powered Vaccine/Water-Pack Freezer for storage of vaccines at -15?C to -25?C and freezing of water packs.
Vaccine storage capacity: 61.25 L
Volume category: >/=60, <120 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 50 grams, R600a, 30 grams, R290, 10 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Compass for blackboard, 40cm long, hard white plastic, with sturdy metal butterfly screw for adjusting tightness by hand. Interchangeable suction foot and compass point in soft plastic. Holder with convenient mechanism that is adjustable for round and square chalk.
....The heart beats are typically conveyed audibly via the measuring/display unit and attached probe which is applied to the surface of the pregnant woman's abdomen. The device aids in determining foetal viability. A portable, hand-held, battery-powered device assembly consisting of a measuring and display unit and an attached probe or interchangeable probes designed to noninvasively detect foetal heart beats using ultrasound/Doppler technology.
....Suitable for professional clinical use, all patient categories neonate, infant, adult
Robust shock resistant design allow use in demanding environments
Ultra-compact pulse oximeter integrated into finger/toe clip
Measuring ranges:
SpO2 resolution: 1% or less
SpO2 accuracy within: +/-3%
SpO2 detection within the range of: 70 to 99%
Pulse rate accuracy: within: +/-3%
Pulse rate detection: 30 to 240 bpm
Pulse rate resolution: 1 bpm)
Enclosure protection IPX2 or better
Suitable for cleaning and disinfection with hospital-grade cleaning products.
Display shows SpO2, pulse rate, signal strength, sensor error or disconnect and low battery.
Power requirements two 1.5V AAA batteries
Accommodates finger/toe thicknesses 8 to 25mm directly or through the use of a separate sensor which can be connected to the device.
Spot-check of arterial blood oxygen saturation (SpO2) and heart rate(HR)
Batteries must allow at least 2500 spot-checks, calculated at 30 seconds per spot-check, or at least 21 hours of operation.
The unit is equipped with an automatic power off feature.
For grasping organs, soft or heavy tissue.
Material: Martensitic steel (quenched, magnetic steel).
Martensitic steel composition: 0.15-0.20% carbon, 12-13% chromium.
Precise adjustment of the teeth.
Hard ratchet, lockable.
Pressure force instrument: tissue grasping forceps, springy.
4 x 5 teeth.
Length: 15 cm.
Reusable.
Urethral catheter with balloon: Foley catheter 2-way with nelaton tip.
Side channel for inflating balloon, ending by a non-return valve with Luer tip connector.
Central channel for urinary drainage, straight rounded distal end with lateral eyes, proximal end with cup connector allowing catheter to be connected to urine bag.
Balloon capacity expressed in ml.
Colour code / external diameter visible on connector.
Length expressed in cm.
To measure the mid upper arm circumference for rapid screening of nutritional stauts of children. Target population: Malnourished children or those at risk, aged 6-59 months.
....Self-priming centrifugal pumping set, capacity 50 Cubic Metres per hour at around 2900 RPM, at 20 metre TMH (Total Manometric Head) for 1-m suction head.
....The product is composed of a bottom plate, three different kinds of metal wire (copper wire, iron wire,nickel chrome wire), terminal, connecting piece etc.
....Size is not less than 400mm * 500mm * 350mm, wooden structure.
The front side of the box body operation hole two, and with a white cloth sleeve connection and sealing,the sleeve is not less than 300mm.
One-person operation case,open two round holes on the front and bring an ultraviolet lamp.
Operating voltage: AC220V 50Hz, UV sterilization tube is 15W.
The simple manual pipette controller can be used to calibrate the pipette and the pipette in the Fixed pipette, and it is convenient and quick to operate with one hand. Specifications 2ml, 5ml, 10ml, 20ml.
....Equivalence Turbidity Standard is packaged in plastic case with a visual comparison card.
Polystyrene technology allows longer shelf life.
Tube size is 15 x 103mm and fits in most spectrophotometers.
Lightweight, chemically, and biologically inert, tear-resistant.
Pants with open ankle and elastic at waist for easy donning and removal.
Inherent barrier protection. Stops submicron particles, even after abrasion.
No pockets
Open ankles
Elasticized waist
White.