Rigid Rear Axle Cutway complete with differential unit, axle shafts and rear drum brakes. A brake drum and a cylinder are sectioned. Carefully sectioned to show the operation of the differential unit where planetary gears, the ring gear and the pinion are clearly dispalyed.
....Training Objectives:
Measuring the mains voltage
Measuring the electricity delivered to the mains grid
Measuring the electricity produced by the solar panel and delivered/taken from the mains grid.
Changing the inclination of the solar panel
Changing the azimuth of the solar panel
Measuring the load current, voltage, power and energy
Setting the solar panel to the most irradiated position
Covering the solar panel with different materials
Calculating the inner resistance of the solar panel
Obtaining the solar panel current voltage curve
Obtaining the solar irradiation data
Obtaining the solar panel voltage irradiation curve
Intended use:
Applicable for molecular/PCR & sterile microbiological works. Various clinical laboratory usage conditions including; Sample/reagent preparation, incubation, centrifugation, vortex, cold storage.
Plasma collection for clinical laboratory tests. Intended for the purposes of molecular diagnostic testing.
Material: clear nonfragile PET plastic and leak-proof rubber cap
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Blood collection vacuum tube.
Volume 6m,
Sterile
Standard color-coded cap.
Pen/Marker writable label space.
Capped, with needle-pierceable vacuum seal cap.
Additive; Inert plasma separation gel & K2 EDTA anticoagulant.
Vaccine storage capacity: 98 L
Volume category: >/= 60, <120L
Energy consumption, stable running (kWh/24 hours): 0.6
Equipment operating voltage and frequency.
220-240 Volt 50Hz /60Hz, or 100-127 Volt 50Hz /60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
R600a, 55 grams
PQS Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Vaccine storage capacity: 58 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF: Grade A
Refrigerant: R290a, 35 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Suitable for use with HB pencil and eraser (made of natural or synthetic rubber); is washable in water; and sufficiently rigid for the student to be able to write with the slate.
Material: Colour white, matt finish (both sides), high impact polystyrene (HIPS) sheeting, thickness 2mm.
resting on the knee.
Slate (individual writing board for students), A4 size (210 x 297mm), white high impact polystyrene sheeting, thickness 2mm, with rounded corners. Silk screen printed on both sides in cyan blue.
Design and rulings: Silk screen printed in cyan blue on both sides.
Reverse side: 8mm lines.
Front side: 1cm squares.
Border: An 8mm border in cyan blue on all sides.
Medical gas flow meter (Thorpe tube design) to regulate and measure theflow rate of medical gas supplied to a patient, maximum flow rate 8 LPM,for medical oxygen.
Graduation shall have over 270 degrees of visibility.
Needle valve and body constructed of brass or aluminium.
Calibrated at 50-55 psi / 345-380 kPa / 3.4-3.8 bar inlet gauge pressure.
Inlet pressure (nominal) > 50 psi (345 kPa / 3.45 bar), peak inlet pressure at least 100 psi (690 kPa / 6.89 bar).
Pressure compensated design to give specified accuracy for whole range of input pressures
Built-in inlet filter.
Thorpe tube design flow meter using DISS input connector for panel /regulator mounting.
Can be cleaned with damp cloth and a disinfection solution.
Transparent, graduated (metric system) column, shatter resistant polymer certified for medical use.
Maximum flow rate when fully opened: 50 L/min.
Inlet and outlet connectors DISS style, other types of connectors available upon request
Adjustment knobs to have rough surface to prevent slipping.
For surgical procedures or any sterile medical procedure to protect both patient and medical staff from cross-contamination. Surgical gloves are sterile and strictly SINGLE USE.
....Water tank, collapsible, 5 cbm (5,000 litres), made from polyester and coated with PVC, UV proof, thermal stability -30°/+70°C, suitable for chlorinated drinking water storage (food grade material).
Water tank, 5000 liters (5 cbm), collapsible, complete set including kit for water distribution with six taps, connection kit, installation kit and repair kit. Food grade material.
Specially designed universal spindle key to fit the opening valve of industrial gas cylinders.
....Double Gauge Damping Balance
....Common artificial materials specimens: silk+cotton, polyester yarns+cotton, silk, silk+polyester yarns, scotching tow, nylon silk, polyester yarn, linen, silk+silver wire, cotton, polyester yarns+spandex silk, silk+linen, polypropylene fiber silk+polyester yarns.
....Glass instrument bottle mouth seal, suitable for all kinds of test tube flasks, different sizes.
....It is an instrument directly measures liquid and gas temperature, can measure in temperature range -30? to 200?, and is mainly used for middle school physics and chemical teaching experiment.
....Tablet Oscilloscope (Book Series)
....Osborne Reynolds Demonstration
....Time of Flight Accessory
....