Earth-Ground Testers Electronic Engineering Lab
....Periodic Table Chart
....The test force is displayed using a large dial gauge indicator. The elongation of the test specimen is recorded on a dial gauge. Students can develop skills in the carrying out of complex project work. The fully assembled system presents an actual fully functional materials tester which can be used for a wide range of materials testing. The test force is generated using a hand-operated hydraulic system. The skills acquired are the planning, execution and checking of assembly, commissioning, and maintenance operations. Is supplied in kit form. In the course of the project they independently develop an appreciation for the fundamentals and correlations involved, and then contribute to the overall outcome using team working skills. The kit contains all the mechanical components, measuring devices, hydraulic components complete with sealing elements, and piping material complete with all connecting elements.
....Benchtop service unit, designed to accommodate a range of different small-scale heat exchangers.
The hot water pump is bi-directional (to allow co-current and counter- current investigations without re-configuring the hardware) and the flow rate is under computer control.
The hot water vessel is made from clear acrylic (for visibility) and includes a 2kW heater with thermostatic over-temperature cut-out and low water level detection.
The cold water system includes a manually adjustable pressure regulator and a flow control valve which is under computer control.
Flow rates for both fluid streams in excess of 5L/min are achievable, but this may be restricted by some designs of heat exchanger .
All data is available to a (user supplied) Windows PC, via a USB interface. This computer is also used to control the flow rates, hot water temperature, and hot water direction.
Full software for educational use is included.
Comprises hot water vessel, hot water recirculation pump, cold water control system, computer interface and all necessary instrumentation.
Up to 10 temperatures (K-type thermocouples) can be monitored using the service unit. Operating range, 0-75°C, resolution 0.1°C.
Two flow meters are included, operating range 0.2 to 9 l/min resolution 0.1l/min
A comprehensive instruction manual is included.
The unit consists of a storage tank and a centrifugal pump with a motor dynamometer on a steel base for measurement of TRUE pump input power, and measuring instruments. Mini Centrifugal Pump Test Set Motor Dynamometer is a self contained bench top unit for studying the centrifugal pump characteristics. Speed control is by an inverter.
Experiments:
Pump input, output and true efficiency at various speeds.
Flow rate vs head at various speeds.
The device simulates various working conditions of the engine, cleaning and detecting the fuel injection nozzle of various automobile, and can also carry out the cleaning of the automobile fuel injection nozzle and the fuel supply system. The equipment adopts ultrasonic cleaning technology and microcomputer oil pressure closed loop control cleaning detection technology.
Features:
On-vehicle Cleaning
Ultrasonic Cleaning
Uniformity & Spray ability Test
Direct Flush
Reverse Flush
Auto cleaning test function
Leakage Test.
Beam Mould 150x150x600 MM, with "X" reinforced bands on the base and upper double reinforced walls and corners.
....The dump rail adopt good heat-treatment steel plate, whichwill abide rough use.
Suitable for any length of non-heat treatment work piece andany other parts which are hard to move. It is easy to operate, take less time.
Standard square alloy bit , easy to replace. Or you can useold bits that used in milling machine.
This unit is mounted on a metallic structure and may be wall mounted.
This unit has been designed to study a simple lifting mechanism and its use to determine the velocity ratio, mechanical advantages and efficiency.
Plastic Bending of Portals teaching apparatus enables a range of laboratory, classroom and computer-based experiments for civil, mechanical and structural engineering students studying plastic theory and limit state design in portal frames.
....Intended use:
To transfer liquids in clinical laboratory settings applicable for molecular/PCR & sterile microbiological works.
Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.
Equipped with one oxygen outlet, provided with controllable flow meter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate 10 L/min.
Contains oxygen monitor to verify concentration.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Flowmeter control allows shutting off flow (i.e. 0 L/min) by user.
Noise level <60 dB(A).
Digital meter that displays cumulative hours of device operation.
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.
Electrical characteristics
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.
Casing and environment
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
The unit includes internally and externally mounted filters for cleaning the air intake.
Unit weight <27 kg.
Material: Austenitic steel (non-quenched, non-magnetic steel).
To dilate the vagina to examine the vaginal canal and cervix.
Speculum, vaginal, self-retaining.
Double blade with a screw mechanism to keep the blades open.
Austenitic steel composition: 16 - 18% chromium; 10 - 14% nickel; 2 - 3%molybdenum.
Blade length: approx. 75 mm.
Blade width: approx. 20 mm.
Reusable.
To measure the mid upper arm circumference for rapid screening of nutritional stauts of children. Target population: Malnourished children or those at risk, aged 6-59 months.
....Used as a middle school physics force line to the electric field in the field of the size and direction of the image to express. The demonstration board adopts the "372" material with good transparency. Products is composed of five pieces of electric field line demonstration board, respectively for single point electrode demo board, two point electrodes demo board, parallel plate electrode demo board, an annular electrode demo board, pointed conductor demo board. The shape and size of the five demonstration boards are 108 * 90 * 6.5mm.
....Main technical specifications: the maximum clamping diameter is 10mm; the no-load speed is 0~600 RPM / min. the battery voltage is 7.2V, 1.5Ah, charger charging voltage is 7.2V to 12V. The overall size of the suitcase is 350 x 260 * 90mm. The product is a rechargeable electric drill, which consists of an electric drill, a rechargeable battery (2 pieces) and a charger.
....Electromagnetic Suit
....Standards not harmful to the environment or to worker safety
Preservative used enhances stability
Biodegradable, safe and non-toxic
Pre-diluted
Do not include formazin
Ready and easy to use.
Protection with comfort
Made of blue neoprene over yellow latex
Raised diamond grip on palm and fingers for good wet or dry grip
Flock lining to absorb perspiration; permits easy on and off
Ideal for general housekeeping, maintenance applications, food processing and food service applications, as well as industrial use.
Straight cuff
Double-dipped construction provides increased protection, versatile chemical resistance properties, and comfort.
Length: 12 in. (30.5 cm)
Thickness: 28 mil.
Industrial Machines Control Assembly Training Stand Kit
....