The seat is provided with a connecting device and a wiring polarity identification; electrode using carbon rod production, diameter 4mm, length 45mm, the closed room size was 120 mm * 50 mm * 25MM, volume 15ml; discharge nozzle is made of glass, the length of about 50mm, and the connecting hose products using milk hose.
The product is made of transparent polycarbonate material. It is made up of experiment base, electrode, airtight chamber, observation tube, air vent and funnel.
The overall size of the instrument is about 150 mm * 60 mm * 190mm, and the operating voltage of the instrument is DC 12V.
Demonstrate the use of solids in thermal expansion and cold contraction.
....Heat-bent walls simplify construction and limit accidental breakage
Triple and quad holders allow glove boxes to be loaded from either the top or side
Clean line storage solutions perfect for laboratory organization, with heat-bent walls to simplify construction and prevent accidental breakage.
Holder offers versatility while also providing space-saving storage
Fits standard glove boxes, accommodating depths up to 3.75 in.
Can be mounted vertically or horizontally, hardware is included.
Solar Training Set Power Case Electronic Engineering Lab
....The Liquid Sedimentation Apparatus is designed to study the settling characteristics and particle sizes of suspended solid. The rear panel is translucent with back lighting. Scales are provided on the tubes. Sedimentation rate is observed using a stopwatch. The tubes can be removed for washing, filling or mixing of solid particles. Five transparent glass sediment tubes are mounted vertically on a rigid frame.
Experiments:
Settling rate curve.
Effect of suspension height on sedimentation rates.
Effect of concentration on sedimentation rate.
Effect of particle size distribution.
Effect of flocculent.
Die-cast in special high tensile aluminium alloy with an inner aluminium liner to facilitate cleaning.
The heavy duty lid is secured by means of butterfly swivel clamps, two of which act as
safety retaining bolts.
A compact pressure steriliser of high quality for use at 0.75 or 1.05kg/cm3, complete with built-in heating elements, control switches and fitted with resettable microtherm cut-out.
Supplied complete with adjustable safety valve, pressure guage, air cock, drain off syphon and inner liner. Also supplied, 10 robust autoclave milk sample bottles and screw caps, 250ml capacity, and 55 metres of autoclave tape.
The cylindrical boiler is filled with a known quantity of water, then heat is given through the resistance. Heat is supplied to the water in the boiler under steady-volume rather than steady-pressure conditions. The Computerized Marcet Boiler is designed to determine the corresponding temperature and pressure values for wet saturated steam at all pressures ranging from atmospheric up to 17 bar. The liquid gradual evaporation will thus cause pressure - and therefore the saturation temperature - to increase in the boiler enclosed space and the values are visualized on digital indicators. Moreover, the transducers and the dedicated software allow the data acquisition of the main thermodynamics quantities and to obtain as a table or as a graph, the acquired values and the thermodynamic calculated quantities.
....The friction disks are pushed together, and force transmission comes about as aresult of the friction. The slip can be varied with the help of anelectronically controlled throttle valve. It replaces the known viscous clutch in four-wheel drive. As soon as a difference in speedcomes about between the front and the rear axle, the swash plate turns in the housing. Fluid is pressed to the disk plunger by hydraulic pistons.
Cut Open Parts:
Differentialhousing
Clutchhousing
Hydraulicpiston
Electroniccontrol unit
Stepper motor
Frictiondisks
Pump plunger
The functionof the pump plungers and the differential can be shown by turning on thegearbox flange.
Electricmotor with inlet pressure pump and all the valves.
Pressure and vacuum mode shift function build-in 82 refrigerants according to standard refrigerants pressure and temperature relationship database.
Real-time vacuum pressure test and percent indicate
Test range Measurement of xacuum: -101Kpa~0Mpa
Positive pressure: 0Kpa~6Mpa
Low power indicate. Batteries life:30H. 9V.
Pressure units: KPa, Bar, Psi, Torr, Kg F/cm2,InHg, MmHg
Refrigerant: -101Kpa~4Kpa
Accuracy: ±0.5%
Overload: 100Bar,10Mpa
Resolution: 1Kpa
Drill's part has patent, can grind the drill's front cutting lip, point angle, lip relief angle, you also can control the centre spot at random instead of centre drill, escape of chips easily, drilling with a light heart.
Tap's part has patent that can grind tap's front cutting lip of 2-flute, 3-flute, 4-flute tap. Choosing can grind 5-flute.
Grinding Wheel: CBN Wheel For HSS Drill Bit / SD Wheel for Carbide Drill Bit.
Complex re-sharpener of screw tap & drill, one machine with two function, easy to use, economical price, with no skill requirement to grind.
With Taiwan diamond grinding wheel, long service life.
Theoretical topics:
Definition and characteristics of a combinatory logic network
The BCD code
DEC/BCD and BCD/DEC code converters
Multiplexer
De multiplexer
Parity logic circuits
Encoders
Decoders
Nine bit 74180 parity generator/detector
A/D converters
Staircase A/D converter
Unipolar codes
Adders
Half adder
Definition and classification of shift registers
Applications
Fault simulation
Operation principle
4 bit bi directional shift registers
Bipolar codes
ADC converter with simple slope
ADC converter with double slope
ADC converter of parallel or flash type
D/A converter with R 2R network
D/A converter with weighed resistances
4 bit synchronous binary counter
4 bit asynchronous binary counter
Synchronous decimal counter
Up/down synchronous counters
Asynchronous decimal counter.
Electronic controller with temperature sensor and setting of the reference variable
Quick-release couplings for connection to hot water supply and ventilation system
Temperature control of a ventilation system
3-way mixing valve dn 20
3 thermometers and 1 temperature sensor with display
Circulating pump.
Water circuit with pump, filter, valve and a nozzle as atomiser
Three-stage heater with thermostat for water heating
Principle of a wet cooling tower with cooling column and forced ventilation
Radial fan for forced ventilation
Tank for additional water compensates for water loss
Display of temperature, differential pressure, flow rate and humidity
Throttle valve to adjust the air flow
Demister unit at the outlet of the cooling columns minimises water loss
Interchangeable cooling columns with different wet deck surfaces available as accessories.
Buckling of Struts Equipment
....Cap closure for 0.1ml & 0.2ml PCR tube-strips for use on most standard Thermocyclers, RT PCR platforms, DNA Sequencers.
....Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate of 5 L/min.
Contains oxygen monitor to verify concentration.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.
Flowmeter minimum flow rate of 1 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flowmeter stand (details under RELATED PRODUCTS).
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Equipped with one oxygen outlet, provided with controllable flowmeter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Noise level <50 dB(A).
Contains flow limiter to prevent overdrawing oxygen flow beyond rated maximum flow rate.
Casing and environment
The unit includes internally and externally mounted filters for cleaning the air intake.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
Unit weight <27 kg
Electrical characteristics
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.
To dilate the vagina to examine the vaginal canal and cervix.
Speculum, vaginal, self-retaining.
Material: Austenitic steel (non-quenched, non-magnetic steel).
Austenitic steel composition: 16 - 18% chromium; 10 - 14% nickel; 2 - 3% molybdenum.
Double blade with a screw mechanism to keep the blades open.
Blade length: approx. 115 mm.
Blade width: approx. 35 mm.
Reusable.
It is used in optical grouping experiment: production and change of shadow, rectilinear propagation of light, pinhole imaging, reflection and refraction of light, optical dispersion, image for plane mirror, simple periscope making, convex lens amplification, focusing and images, camera simulated experiment and formation of myopia simulated experiment.
....For calibration of turbidity meters. Includes one each of 60-mL HPDE bottle of four NTU standards.
....