All process variables accessible as analogue signals at lab jacks
Experimental unit for networking of industrial controllers
2 signal generators
Profl bus DP interface card for PC
2 digital controllers, configurable as P, PI or PID controllers, with field bus interface.
Syringe, three pieces: barrel with luer nozzle, stopper and piston/plunger.
Intended use: inject fluids into, or withdraw fluids from, the body.
Blister packed. Disposable.
The product is mainly composed of the following parts: in the middle of two V-shaped base is connected with a metal rod, 2 pcs vertical rod, 2 pcs bosshead, a flask holder, a universal clamp , table clamp , a hoop, circular tray ,4 pcs hook roll ,a hook rod , an insulating rod. The product for physics teaching can be assembled into a universal bracket, vertical, parallel, hanging, clamping, placing various experimental support.
....Rocket Launch Simulator
....Lightweight, breathable fabric keep workers cool and comfortable.
Elastic wrists without pocket
Snap front
White.
The wall mounted apparatus consists of a fixed pulley, a second interchangeable pulley and a loaded rope belt with 2 load hangers in a complete loop.
Four pulleys with vee grooves typically of 60, 90, 120 degrees and flat rim supplied.
Determination of the coefficient of friction between a steel pulley and cotton rope; investigate belt tensions; evaluate effects of different `V` angles in the pulley, and of different lap angles.
An Instruction manual for student and lecturer provided.
Alternative mounting positions provided to vary the lap angle.
Set of weights.
The Oil Pump Supply Module is part of an equipment series that facilitates the investigation of a wide range of engines and machines. The flow is adjusted on a pressure valve and recorded using an oval wheel meter. Other sensors measure the temperature, intake and delivery pressure. Different oil pumps can be operated on the supply module and investigated in terms of their characteristic behaviour. The corresponding sensor connections and digital displays are located on the measuring equipment block. The pumps are connected into the experimental set-up using hydraulic hoses with quick action couplings.
....The roller-cell pump has a Plexiglass cover so that all parts are visible.
The pump runs when connected to a 12V-battery.
The pump can be taken apart.
The interior mechanical structure and function of the back drive axle can be clearly understood through its demonstration and operation. The Rear-Drive Bridge Module Model is ideal teaching equipment for colleges, secondary vocational and technical schools, truck driving training and vehicle repairing field.
....Compression testing machine 2000 KN motorized with control unit high stability to test blocks max. 500x300 mm, cubes up to 200 mm side and cylinders up to dia. 160x320 mm.
....This board allows the study of the following circuits:
Furthermore, the board includes interface circuits and a connector to allow for direct and easy interfacing to systems, devices and circuits prepared by the students. Counters, frequency dividers, cyclic programmable timers, data transfer between two shift registers.
The board is composed of:
8 to 1 line multiplexer
1 to 8 line demultiplexer
NOT with open collector output (4 off )
Optoisolators (4 off )
4 bit comparators (2 off )
4 bit shift registers (2 off )
4 bit BCD counters (2 off )
A 22 pole connector, step 3.96 mm.
Digital multimeter for direct and alternating current, battery operated
Commercial tools for the assembly and servicing of refrigeration systems
Battery operated leak detection device suitable for refrigerant R134a
The modular frame is a tubular steel structure, treated with electrostatic painting. It has 4 lines for manual and fast fixation of the modules without the need for tools. Programmable Logic Controllers Modular Trainer allows the study of the PLC and HMI. The components, as well as their terminals and access points, are identified with the respective symbol printed in silk-screen. All terminals and connection points are available through 2 or 4mm. terminals (according to the voltage).
Module with switches for digital input signals simulation. It includes 8 contact pulse switches, NC/NO.
Module with switches for digital input signals simulation. It includes 4 contact pulse switches, NC/NO and 4 contact retention switches, NC/NO.
Module with switches for digital input signals simulation. It includes 8 fixed contact switches with retention, NC/NO, for simulating the logic levels.
Module with step motor, with 4 bit electronic driver, with light indication for each bit.
Module with 4 relays for 10 A and 24 Vdc coil, suitable for PLC with NPN or PNP outputs.
Module with 8 led for light indication of output digital signals, suitable for PLC with NPN or PNP outputs.
Module with DC motor and encoder, suitable for PLC with NPN or PNP inputs.
Module with Analogue/Digital converter, 8 bits A/D converter, with analogue signals input from 0 to 10 Vdc or from 4 to 20 mA.
Module for Digital/Analogue converter, 8 bits D/A converter, with maximum analogue output signals adjustable from 0 to 10 Vdc or from 4 to 20 mA.
Module with 2 linear potentiometers for simulation of voltage or current signals (4 to 20 mA and 0 to 12 Vdc).
Module for analogue signals measurement. Possibility to measure 2 signals simultaneously. One of the inputs is suitable for current signals from 4 to 20 mA and the other for voltage signals from 0 to 10 Vdc.
Supplied with a set of 30 connection cables, 2 and 4 mm, and an experiment manual.
Sending and measuring pneumatic and electrical signals
3 pressure regulators with manometers
Adjustable power supply unit as DC voltage source
Investigation of transmission behaviour and calibration of electronic and pneumatic control loop components
3 digital pressure gauges with differing measuring ranges
2 adjustable potentiometers
2 switchable AC voltage sources with differing voltages
3-channel line recorder with freely selectable measuring ranges
Separate high-grade universal calibrator for voltage, current, temperature and resistance
Freely configurable industrial controller
Digital voltmeter
Digital ammeter.
Syringe, two pieces: barrel with Luer nozzle and piston/plunger or three pieces: barrel with luer nozzle, stopper and piston/plunger.
Intended use: inject fluids into, or withdraw fluids from, the body.
Blister packed.
Iodine Sublimation Tube
....Used to study the principle and equilibrium conditions of the lever.
200g, 1g, pointer type. Including 1 base, 1 beam with tray, tray box, sliding poise, red pointer. Balancing weight: 8 pcs 20g, 4 pcs 10g, 1 pc ?-shaped sliding poise.
Reagent Bottle Tray
....The detachable transformer is equipped with 4 sets of induction voltages, 6V, 8V, 9V, 12V, 24V.
....Made from high-quality 45 g/m2 SMS fabric
Detailed finishing, 3-pocket design and front snap closure
The High Performance Lab Coat, White Frost is premium protective apparel made from top-quality materials and designed to provide reliable barrier protection without sacrificing comfort or style.
Fluid-resistant fabric Level 2 standards
Each bag contains 10+2 units, for a total of 12 vs. 10 per package from the competition.