Centrifugal Compressor Module

Product Code: LBNY-0005-13700020 - (Centrifugal Compressor Module)

Experiments
Determination of the specific speed of the fan Essential Base Unit
Performance of a centrifugal fan
Universal Dynamometer
Variation of fan performance with type of impeller
Variation of fan performance with speed
Non-dimensional performance curves.

Recommended Ancillaries:
Pipe Flow and Nozzle Kit  
VDAS-F (frame mounted version of the Versatile Data Acquisition System).

....


   

Unsymmetrical Bending And Shear Centre

Product Code: LBNY-0005-13800020 - (Unsymmetrical Bending And Shear Centre)

Experiments:
The relationship between the vertical and horizontal deflections and the principal moments of area of each section.
The shear centre of various asymmetrical sections.
Horizontal  and vertical deflection of different asymmetrical sections at various angles.
Horizontal and vertical deflection of different asymmetrical sections under various loads.

....


   

Universal Drive Module Apparatus

Product Code: LBNY-0005-14000020 - (Universal Drive Module Apparatus)

The floating motor is free to rotate and with a moment arm, rests against a load cell. Attached to the motor shaft is a coupling. The engineering drawing for the coupling mating half is supplied for the customer to produce.
Universal Drive Module Apparatus consists of a sturdy cradle, with bearings at either end. The motor is speed controlled using the control box supplied. The signal from the load cell is also fed directly into the control box. The torque being applied to the attached apparatus can be calculated using these parameters. The front panel of the control box has the speed control potentiometer, tachometer display for motor speed and the force display for the load cell signal. Suspended between the bearings is a motor, which gives drive to a variety of customer designed apparatus.

Experimental Capabilities:
Calculations involving torque, moment, speed and power
Introduction to drive system.

....


   

Industrial Air Conditioning Pilot Plant With Heat Pump And SCADA

Product Code: LBNY-0005-14100020 - (Industrial Air Conditioning Pilot Plant With Heat Pump And SCADA)

An Industrial Air Conditioning Pilot Plant with Heat Pump and SCADA for advanced study of the operation of an air to water heat exchanger.

Industrial Air Conditioning Pilot Plant With Heat Pump And SCADA
All of the typical hydraulic, mechanical and thermodynamic operation and characteristics of a heat pump are also studied using a wide range of sensors.
The Industrial Air Conditioning Pilot Plant with Heat Pump and SCADA allows advanced and in-depth study of the operation of an air to water heat exchanger. It also allows students to study the cycle reversing valve and thermostatic expansion valve that are part of the heat pump.
The has been designed and manufactured to incorporate all current safety standards.
The refrigerant used complies with anti-pollution legislation.

....


   

Mass Oscillations And Hammer Study Unit

Product Code: LBNY-0005-16000020 - (Mass Oscillations And Hammer Study Unit)

The Mass Oscillations And Hammer Study Unit is provided with a constant level container connected to the water supply by means of a pipe.
In the hydraulic systems the flow variations produce two phenomena: the mass oscillation and the water hammer which are related each other but have different characteristics.
For the water hammer test, the unit is provided with a quick closing valve with manual control in order to obtain an immediate flow interruption.
The oscillation test section is made of stainless steel 3 m long provided with the valves necessary for the flow control and with two pressure measurement devices, the electric signal of which is sent to a double trace memory oscilloscope which allows to examine, in all the phases, the phenomena of mass oscillation.
The Mass Oscillations And Hammer Study Unit is available in two different solutions:
Hydraulic supply from mains
Hydraulic supply from provided with additional tank.

Experiments:
Determination of the transient pressure curve of a water hammer by means of an oscilloscope
Demonstration of the losses in the reservoir and in the balance tank
Water hammer demonstration
Mass oscillation demonstration
Visualization of oscillation characteristics in the balance pipe.

....


   

Engine Speed Control Apparatus

Product Code: LBNY-0005-18500020 - (Engine Speed Control Apparatus)

Experiments:
The measurement of system dynamics from step response information.
Inner loop feedback compensation.
The use of dither signals in the compensation of system non-linearities.
P+I controller design.
It is good for extended or advanced control experiments, and is ideal for student project work. The flexible design of the equipment allows the user to develop many other analysis and control exercises to suit their needs. 

....


   

Manual Air Condition

Product Code: LBNY-0005-18600020 - (Manual Air Condition)

The components of this unit are pre-assembled with a compressor operating with refrigerant. A large electric moter is mounted with a control housing in a self contrained heavy duty roller cart. Manual Air Conditioning Trainer allows the student to learn the basic test and maintenance procedure for the refrigerant loop. Charging checking for leaks, A replacing components, servicing parts, and other tasks are covered in this program. Included are a set of charging and manifold gauges and battery cables.

....


   

Fuel Cells Systems Trainer

Product Code: LBNY-0005-18400020 - (Fuel Cells Systems Trainer)

Fuel Cells Systems Trainer has been designed for the study of fuel cell systems. It is safe and easy to be operated. It teaches their engineering principles and it allows performing a set of experiments for educational purposes.

Training Objectives:
Fuel Cells Systems Trainer is very flexible, modular and suitable for the understanding of basic principles as well as more complex technology concepts.
It allows performing the following experiments:
Familiarize yourself with the trainer
Calculation of the energy efficiency of the (Proton Exchange Membrane) PEM Fuel Cell  
Performance of the (Proton Exchange Membrane)PEM Fuel Cell with fixed loads, with DC/DC Converter
Performance of the (Proton Exchange Membrane) PEM Fuel Cell with fixed loads, without DC/DC converter
Recording of the current/voltage characteristic curve of the (Proton Exchange Membrane) PEM Fuel Cell with variable load.

....


   

Electrical Resistance Strain Gauge Apparatus

Product Code: LBNY-0005-17600020 - (Electrical Resistance Strain Gauge Apparatus)

A cantilever has a single gauge bonded onto its surface, and an identical gauge is fixed to an unstressed piece of the same material for temperature compensation. The two gauges form part of a wheatstone bridge which has a balancing potentiometer, and whose meter is calibrated directly in microstrains. The Electrical Resistance Strain Gauge Apparatus has been designed to illustrate the basic features of electrical resistance strain gauges and their application in measuring bending and torsion. A detailed label on the unit shows the wheatstone bridge arrangement and how the specimen strain gauges connect into the circuit. The cantilever is loaded by the load hanger and calibrated weights hung from its free end. A torsion bar is also supplied having two gauges bonded orthogonally at 45º.

Experimental Capabilities:
To show the application of Electrical Resistance Strain Gauge Apparatus in the measurement of stress due to bending and torsion
Visibly shows location of Electrical Resistance Strain Gauge Apparatus within wheatstone bridge arrangement and the position and use of balancing potentiometers
To demonstrate the use of wheatstone bridge arrangements in measuring change of resistance
Dummy, temperature compensation gauges
Wiring of Electrical Resistance Strain Gauge Apparatus
With optional extras to show other methods of temperature compensation in conjunction with tension and compression specimens.

....


   

Pipette,tip,barri,ster,2-20ul,RACK-960

Product Code: LBNY-0007-22600020 - (Pipette,tip,barri,ster,2-20ul,RACK-960)

Intended for molecular medical laboratory, PCR work. Micropipette tips for use with standard Micropipettes used for pipetting small amounts of liquid in the laboratory.

....


   

Tube,blood coll,w/capil,0.2 ml, EDTA 100

Product Code: LBNY-0001-21700020 - (Tube,blood coll,w/capil,0.2 ml, EDTA 100)

Used for capillary blood collection for clinical Lab tests.
Capacity: 0.2 ml.
Material: plastic.
Capped with a pierceable flat vacuum seal.
Indicates maximum fill with clearly visible line.
Blood collection tube
Prefilled with K2 EDTA,
Capillary tube included.

....


   

Cold box,BK

Product Code: LBNY-0001-2100020 - (Cold box,BK)

Cold box, Small, Long range
Vaccine storage capacity: 12 litres
Cold life at 43°C without openings: 156 hours
With hinged lid and carrying handles.
Supplied with 42 x 0.4L icepacks as a standard.
Weight fully loaded: 45 Kg

....


   

Mains Powered Vaccine Refrigerator 242 L

Product Code: LBNY-0004-2100020 - (Mains Powered Vaccine Refrigerator 242 L)

Vaccine storage capacity: 242 L
Volume category: >120L
Refrigerant: R600a, 130 grams
Energy consumption, stable running (kWh/24 hours): 0.638
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF- Grade A
PQS Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Equipment operating voltage and frequency:?220-240 Volt 50Hz /60Hz, or 100-127 Volt 50Hz /60Hz, 1ph.

....


   

Solar Direct Drive Vaccine Refrigerator with no battery 200 L

Product Code: LBNY-0005-2100020 - (Solar Direct Drive Vaccine Refrigerator with no battery 200 L)

Vaccine storage capacity:200L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 65 grams.

....


   

UTDL Bluetooth, Multi-use

Product Code: LBNY-0006-2100020 - (UTDL Bluetooth, Multi-use)

The device shows any temperature alarms that have occurred via a multicolour LED indicator. The multi-use, User-programmable Temperature Data Logger (UTDL) with a Bluetooth interface for data download, analysis and programming of device settings via a Bluetooth-enabled smartphone.
When connected to a smartphone via the Bluetooth interface, the device generates a report via the free mobile application. Reports and data can be exported from the web application in PDF or CSV file formats. Data is then uploaded and archived via the smartphone’s internet connection to the web application (accessible on the internet web browser of a PC or Mac).

....


   

Book, exercise, A4, ruled, 96pgs

Product Code: LBNY-0010-2100020 - (Book, exercise, A4, ruled, 96pgs)

Printing: one color Pantone cool grey 5 recto/verso
Lines: 8 mm lines without left, right and bottom margins and with a top margin of 18 mm.
Printing: One color Cyan blue and water based glossy varnish recto only
Finishing: Saddle stitch (stainless steel) along the 297 mm and trim to size
Cover: 75% recovered paper fibres (post and pre-consumer waste) 140 GSM one side coated
Size: closed A4 size (210 mm wide x 297 mm long), open A3 (420 mm x 297mm)
Paper: 75% recovered paper fibers (post and pre-consumer waste) non coated 70 GSM.
Pages: 96 pages (48 sheets).

....


   

Sphygmomanometer,(child),resilient

Product Code: LBNY-0014-2200020 - (Sphygmomanometer,(child),resilient)

The aneroid manometer consists of a metal bellows, which expands as the pressure in the cuff increases, and a mechanical amplifier that transmits this expansion through a lever to an indicator needle, which rotates around a circular, calibrated scale. A device designed to measure blood pressure consisting of an inflatable cuff that fits around a limb (arm or thigh), an inflation bulb for controlling the air pressure within the cuff, an aneroid manometer, and tubing. The manometer is hand held (portable); blood pressure measurement is taken in conjunction with a stethoscope.

....


   

Simulator, premature infant care, light

Product Code: LBNY-0015-2200020 - (Simulator, premature infant care, light)

Simulator consists of a light skin manikin, that has an appearance andsize of approximately 32 weeks old premature infant, together with Breastfeeding Simulator and Preterm Wrap.
Material of the simulator: Vinyl, Silicone, Polyoxymethylene - POM, Poly vinyl chloride - PVC, Polypropylene - PP, Thermoplastic polyurethane – TPU.
Texture of the simulator: Soft and smooth, friction free to demonstrate the desired procedures. Realistically sculpted to resemble and simulatea premature infant, feeling smooth / resilient / bony as relevant andsuitable for simulation.
Simulator is used tofacilitate learning preterm infant care, including thermal care and feeding support such as exclusive breastfeeding, alternative oral feeding and enteral feeding with nasogastric tube. Simulator, premature infant care, light complexion.
Can be used to practice:
Breastfeeding - proper positioning and attachment.
Skin-to-skin care
Cup feeding
Intragastric tube placement.

....


   

Face mask, venturi, child, single use

Product Code: LBNY-0017-2200020 - (Face mask, venturi, child, single use)

Face mask to provide oxygen at flow rates up to 12 LPM. Allows for precise oxygen delivery by utilizing different sized ports to change FiO2 (24 – 60%). Also known as air-entrainment masks able to provide total inspiratory flow at a specified FiO2.

Allows for precise oxygen delivery, with specific concentrations ranging from 24-60%.
The kit of the mask includes the tubing, humidity cup and multiple jets, which are color-coded and indicate the percentage of oxygen.
Mask is soft, transparent, with well-fitting mould.
The nose clip is adjustable.
The tubing is terminated with standard or universal hose end connector.
Individually packed.
Tubing compatible with standard oxygen connection tubing.
Tubing length: 2 meters
Non-sterile.
Child size.
Single use.

....


   

Catheter,urethral,CH14,ster,disp

Product Code: LBNY-0021-2200020 - (Catheter,urethral,CH14,ster,disp)

Atraumatic, soft, rounded closed distal end with 2 lateral eyes, proximal end with cup connector allowing catheter to be connected with urine bag.
Urethral catheter without balloon, nelaton tip.
Colour code cup connector.
Length expressed in cm.

....


   
Support