Portable suction machine for airway aspiration, minor surgery, emergency, patient transfer, suitable for use in hospitals and at home.
The unit provides intermediate and continuous suction. Continuous is limited to 30 minutes after which the unit should be given 30 minutes to cool down.
The flow rate at maximum vacuum is ≥ 33 L/m (2 m³/h).
The unit is provided with a suction tube of at least 1.5 meters.
The suction tube is made of medical grade silicone which is autoclavable at 121°C.
During operating the unit's noise level does not exceed 65.5 dB.
The unit is designed in such a way that it requires little or no oil.
The pump is equipped with a provision preventing fluid flowing to the pump if the collection jar is full (overflow control valve).
The unit is provided with one (1) reusable collection jar.
The unit has maintenance free operating.
A gauge indicating the negative pressure generated by the unit.
A hydrophobic bacterial filter is included in the airline to the pump.
The user adjustable suction ranges between 0 and at least 525 mmHg (70 kPa).
The unit should be provided with a carrying handle and storage provisions for all accessories, allowing to carry the unit with one hand.
The body is to be constructed of stainless steel or material which is non-corrosive or has a corrosion resistant coating.
The unit is equipped with a lead-acid battery.
The battery should be able to power the unit for up to 60 min.
The design of the device should be such that it is easy to clean/disinfect by avoiding difficult-to-reach areas and having smooth surfaces.
The device should have a sturdy, shock resistant casing.
A visual alarm should be incorporated in the unit signalling depletion of the batteries.
The unit should be provided with a battery level indicator and a charging indicator.
The unit should be able to simultaneously operate and charge from 12 Volt as well as the main power grid.
Power requirements: 230 Volts - 50Hz
The weight of the unit does not exceed 5.5 kg.
Used for aspirating fluids / secretions from the operative area.
Material: Austenitic steel (non-quenched, non-magnetic steel).
Austenitic steel composition: 16-18% chromium, 8-14% nickel, 2-3% molybdenum.
Curved.
Suction tube with removable tip and tubing connector.
Length: approx. 27 cm.
Diameter: approx. 6 mm or 8 mm.
Reusable.
Urine collection bag.
With reinforced eyelets for hanging;
Kink resistant and transparent plastic inlet tube, length 85-95 cm, with universal connector and protective cap.
Medical grade plastic bag;
Capacity 2000 ml;
With graduations, every 100 ml to allow proper reading of the liquid contained in the bag.
Electronic scale for weighing adults and children, for use up to 150kg with 100g precision. Scale allows a child's weight to be measured while being held by an adult. Suitable for clinical and survey settings. Supplied with customer replaceable batteries, solar panel and AC adapter with multi-country plugs.
Performance
Measuring range 0.1 to 150 kg.
Accuracy: ± 100 g over the entire range of measurement
Graduation: 100 g minimum.
Taring: Taring function is automatically initiated, without pressing any operational button. Taring function is initiated once a parent holds a child after being weighed first (mother-child mode).
Portability: Easy to carry by a health worker in the field. Maximum weight 4.0 kg; maximum dimensions:360 mm for length, 400 mm for width and 70 mm for height.
The on/off button does not serve any other purpose and is encased to be protected from rain, dust and humidity.
Light-coloured foot mat to avoid heating if exposed to direct sun light Mother-child mode is the default mode, alternative mother only mode can be activated by pressing an operational button.
Main on/off button has a feature to prevent accidental switching on or off and is easily accessible.
Footprint markings to indicate correct standing position (optional).
Demonstration of Vernier Caliper
....Measuring range: -16??+81?, accuracy: ±1?, resolution: 1?.
....It can be used not only in the classroom demonstration of teachers, but also in the hands-on operation of students. The operation is simple, the effect is obvious, the durability is good, and the utility model has good practicability. The dialysis experiment apparatus is used in the experiment of colloid dialysis in high school chemistry.
....It is used to demonstrate experiment of plant photosynthesis, respiration and transpiration. It consists of transparent container, funnel, top head, test tube, test tube rack and gas collecting cap.
....Disk dynamometer, the diameter of 10cm, with zero device specifications are as follows:
1 N scale: 0.1N
2N scale: 0.2N
5N scale: 0.1N.
Electrical Transformer Trainer Electronic Engineering Lab
....Disks Single Slit and Multiple Slits For Difraction Experiences
....Scanning Electron Microscope Bench Top
....The Electro Fluid Power Learning System provides learners with the components to set up a variety of industrial relay control circuits using ladder diagrams and Boolean logic. Electro Fluid Power Learning System can be used with eight different basic pneumatic or hydraulic learning systems to teach electrical relay control of hydraulic and pneumatic systems and their industry applications. Some of these components include selector, pushbutton, limit, and pressure switches; control and timer relays and hydraulic and pneumatic directional control valves. Learners will practice industry-relevant skills related to these new topics including developing a sequence of operations given an application, connecting and operating an indicator lamp given a ladder diagram, and many more. In addition to strong curriculum and industry-standard parts, the Electro Fluid Power Learning System includes an instructors guide, install guide, student reference guide, and the option to purchase an interactive multimedia format of the curriculum. The learning systems that can be used with the Electro Fluid Power Learning System include Basic Hydraulics, Basic Pneumatics, Double-Sided Hydraulics, Double-Sided Pneumatics, Basic Fluid Power, or Double-Sided Basic Fluid Power.
Features:
Pre-Mounted Components for quick setup and inventorying
Plug-in Quick Disconnect Component Connections
Industrial Standard Components
Table-top or Bench Mount
Quick Setup
Portable
24 VDC Electrical Control Power.
Induction motor with both stator and rotor three-phase windings.
....The range consists of a series of different cutaway models of drive system components. The mechanical functionality of all components is retained in full. Each of the cutaway models is securely mounted on a base plate to which handles are attached for carrying purposes. All components are industrially relevant and have been prepared such that individual active elements are clearly visible to the user. All mechanisms are hand-driven.
....The plant is modular and allows to connect other components. The student is provided with teaching and checkout means that allow him to learn the fundamentals for a correct sizing of the heat production unit, of the distribution circuit and of the radiators.
It enables the student to compare different types of circuit based solutions and to know deeply different kinds of heating systems. The Heating Plant shows the fundamental functions of a heating system for civil use.
Module A: Radiator And Fan Coil
Module B: Floor Heating System
The unit is supplied with a manual which describes all the parts of the trainer, the installation and utilization procedures, as well as many exercises with the relative results.
The Plant is supplied in two versions:
With gas fired boiler
With electrical boiler
Civil Heating Plant With Gas Fired Boiler
High efficiency gas fired boiler:
Leak detector with acoustic alarm.
Power: 24 kW;
Vent stack.
Gas meter.
The components are clearly but compactly arranged in a manner similar to that used for many domestic air-water heat pumps and all are visible from the front of the unit.
The Water Water Heat Pump consists of a hermetic compressor, an efficient plate heat exchanger condenser and evaporator, a liquid receiver, a thermostatically controlled expansion valve.
The operating cycle is as follows:
Slightly superheated Refrigerant vapour enters the compressor from the evaporator and Water Water Heat Pump pressure is increased. Heat is given up to the cooling water and the refrigerant condenses to a liquid before passing to the liquid receiver and then the expansion valve. This brings about a rise in temperature and the hot vapour enters the water cooled plate condenser.
Operated clutch
Function of thebleeding of the unit
Function and interaction of the master cylinder and slavecylinder of a hydraulically
Using aluminum alloy box structure.
Main Functions:
To understand the application of dc servo motor, dc servo drive , dc servo manual control experiment, dc servo typical position closed-loop control application experiment, complete the analog circuits realize dc servo motor position closed-loop adjusting loop (P, I, D) related training.
Training Project of DC Servo Motor Closed Loop Control Training Device
DC servo manual control experiment
DC servo typical speed closed-loop control application experiment
DC servo motor know applications
The dc servo drive know applications.