Complete Vergnet hydro-pump, type HPV 60-2000, but supplied with 55 metres each of complete pressure (command/transmission) and riser (discharge) pipes.
Foot pump, for 55 metres installation depth.
Supplied with
1 x pump barrel
1 x command hose
1 x lower pumping element, stainless steel
1 x delivery hose
1 x base plate with sealing pins
1 x command cylinder, stainless steel
1 x pack of clips
1 x tool kit
1 x installation manual
1 x maintenance manual.
The instrument can be used in the experiment of DC motor and AC / DC power generation experiment. In the motor experiment, change the current flow in the coil or the direction of the magnetic field to change the direction of rotation of the coil.
....The table contains a total of 81 elements. Including element storage number, element name, element number, and electronic layer arrangement, parentheses refer to the arrangement of the energetic electron layer and the coarse to atomic mass. Fabric, ribbon, color printing.
....Analog Multimeter (DC 1000V, AC 750V, 1KΩ) Electronic Engineering Lab
....Digital Multimeter AC 500V DC 500V 200MΩ Electronic Engineering Lab
....The experimental capability ranges from the measurement of friction torque under load, to determine the pressure distribution in a journal bearing, to plot a locus curve of a journal and to determine the bearing attitude for different conditions of load and speed. The behaviour of a classical journal bearing with hydrodynamic lubrication can be investigated with the apparatus. The radial load of max. 500N is adjusted manually with a hand wheel. The drive is an asynchronous motor with frequency converter. Five different journals are used to examine bearing clearance. X and Y positions are measured using inductive displacement sensors. All variables (speed, load, friction torque, oil supply pressure, oil peak pressure, oil temperature, X-displacement, Y-displacement) are indicated on 4-digit displays. The friction torque is measured by means of a lever arm equipped with an electronic force sensor.
....Panels and has the capacity to add another set to the opposite side to double your basic hydraulics training capacity. Basic Hydraulics Learning System introduces industry-relevant hydraulic skills while showing how they apply to fundamental hydraulic principles, such as pressure and flow. After completing this learning system, learners will not only understand concepts like flow rate versus cylinder speed and pressure versus cylinder force, but also be able to operate, install, design, and troubleshoot basic hydraulics for various applications. Storage slots are located under the work surface where learners can conveniently store component panels until they are needed. The Basic Hydraulics Learning System mobile workstation is constructed of durable welded steel to provide a sturdy, long-lasting learning station.
Features:
Features standard industrial-grade components in order to provide learners with real-world experience.
Panels can be easy removed and repositioned as necessary to facilitate the completion of the tasks.
Maximize your basic hydraulics training area by providing double the learning capacity of most systems.
Introduces industry-relevant hydraulic skills while showing how they apply to fundamental hydraulic principles.
Three-Phase Synchronous Machine with smooth inductor and three-phase stator armature winding for operation either as alternator or synchronous motor.
Power: 1 kVA
Current: 2.6/1.5 A /Y
Voltage: 220/380 V/Y
Rated speed: 1500 rpm, 50 Hz
Rated speed: 1800 rpm, 60 Hz
The model is plugged onto the base unit, secured using fasteners and connected with refrigerant hoses to become a complete refrigeration circuit for the air cooler. In systems for room cooling the air to be cooled is aspirated from the room by a fan, cooled and fed back into the room. This model demonstrates the principles of room cooling and the components of an air conditioning system. This is part of the HSI training system for refrigeration and air conditioning technology. In combination with the base unit the operational model of a simple air conditioning system is created.
....Commercial Refrigeration Unit With Fault Simulation device can be used to train students to master the theoretical knowledge and practice skills of the commercial refrigeration system.
Features:
Selection of cooling stage via solenoid valves
Semi-hermetic piston compressor, air-cooled condenser
Mobile refrigeration unit with normal cooling stage and deep-freezing stage
Individual and parallel operation of the cooling stages possible
All fans are speed-controlled
Cooling stages: insulated chambers with air-cooled evaporators
Built in faults set module.
Suitable for field mixes of low medium strength concrete.
Drum volume: 125 liters
Power supply: 230V 1ph 50 Hz - 0,3 HP
Yield: 75 liters of concrete
The heat transfer between the pipe wall and medium can be studied. Baffles guide the air through the pipe bundle in a cross-flow. The air duct with the pipe bundle heat exchanger is fitted to and heated electrically. The power and surface temperature at the heater are measured and displayed on the base unit. The number of deflections can be varied by removing and adding baffles.
....This station performs the role of assembling a working industrial directional control valve using a combination of servo robotic and pick and place technologies. The Servo Robotic Assembly Station trains students for pick and place assembly, and teaches interfacing, problem solving, programming, sequencing and operation for servo robotics, gravity feeders, pneumatic screw feeders, and part insertion. Servo Robotic Assembly Station, 5 of the 870 Mechatronics Learning System. The Servo Robotic Assembly Station is a small mechatronics system in itself with multiple, integrated technologies that can be used stand-alone or in combination with other stations. The Servo Robotic Assembly Station has two mobile training workstations with slotted work surfaces that contain an operator station, Pegasus II servo robot with teach pendant, spring/knob feed module, screw/knob engagement module, spool insertion module, screw feed module, parts presentation module, finished parts storage module, parts set, assembly shuttle module, a pneumatic distribution module as well as an electrical distribution module, an electro-pneumatic valve manifold, and a digital I/O interface module. Industrial safety and operation are emphasized on all mechatronic stations.
Features:
Pick and Place Assembly
Servo Robotics
Pneumatic Screw Feeders
Gravity Feeders
Part Insertion.
The main metallic elements are made of anodized aluminum.
The unit is a bench top-unit with an anodized aluminum profile structure, and painted steel panel.
his unit is composed of:
A piston with a millimeter scale to measure the linear motion.
A vertical pivot links the rotary element (crank) and the piston.
A rotary element (crank) with a graduated disc to read the angle.
Automotive Electro Trainer provides a "hands-on" working knowledge of voltage, current, and resistance with series and parallel circuits. Over 250 of these currently used to train. Automotive Electro Trainer kit allows students to gain a foundation in the principles of electricity and electronics. Graphic symbols are screened into each component's acyrlic background. This helps students to understand circuit reading and wiring diagrams. It provides a "hands on" working knowledge of voltage, current, and resistance with series and parallel circuits.
....Intended use:
Applicable for molecular/PCR & sterile microbiological works. Various clinical laboratory uses including centrifugation and short-term sample storage.
Surgical scissors used for cutting or dissecting delicate tissue.
Material: Martensitic steel (quenched, magnetic steel).
Martensitic steel composition: 0.16-0.40 % carbon, 14 % chromium.
Thin, curved, with blunt end blades.
Length: 23 cm.
Reusable.
Instrument that cuts by shearing: surgical scissors Metzenbaum/Nelson.
Sterile suction catheter for single use
Proximal end with cup connector, conical tip, allowing the tube to be connected to devices such as suction pump system
Open distal end, straight, with two side windows
Single channel tube
Material: Polyvinyl chloride (PVC)
Length expressed in cm
Sterile
Disposable
Size selected: Diameter CH08, length approximately 50cm
Initial sterilisation method: Ethylene oxide gas.
Colour code/ external diameter: Visible on cup connector.
Pack of 50 tapes with pictorial and text instructions for use printed on the reverse side, reusable. Adults' Mid Upper Arm Circumference (MUAC) measuring tape with a range of up to 50 cm.
....