The transmissions in the individual gear steps are not implemented with planetary gear trains, but with spur gears. In the cutaway torque converter, one sees the pump and turbine wheel, the free wheel and the converter lockup clutch. A very extensive description of the function is supplied. The shifting processes are initiated electronically, with the gears being shifted by hydraulic clutches via theelectro-hydraulic control unit.
....Beam Mould 150x150x600 MM, with "X" reinforced bands on the base and upper double reinforced walls and corners.
....The dump rail adopt good heat-treatment steel plate, whichwill abide rough use.
Suitable for any length of non-heat treatment work piece andany other parts which are hard to move. It is easy to operate, take less time.
Standard square alloy bit , easy to replace. Or you can useold bits that used in milling machine.
Circuit blocks of Memories
Types of memories: RAM and EPROM
Elementary memory cells.
Memories
Elementary memory cells
Structure and operating principles
Theoretical topics of Memories
Memory classification
RAM memory
Sequential memory
Terminology and main characteristics
ROM memory
Fault simulation.
The trainer enables the measurement of air humidity with four different instruments which can be directly compared to each other: two different hygrometers, a capacitive hygrometer and a psychrometer. There are different measuring methods to determine humidity. Psychrometers operate based on the principle of evaporation cooling and compare the ambient temperature with the wet bulb temperature to determine the humidity. The measurement of the air humidity plays an important role in many branches of industry, e.g. during drying or in the air conditioning of buildings and vehicles. Hygrometers utilise the property of specific fibres, e.g. hair, to expand with increasing air humidity. The core element of the trainer is a climatic chamber with transparent door. In the capacitive sensor the dielectricity constant of a layer and with it its capacity changes due to the water molecules absorbed. This chamber can be humidified and dehumidified and contains the four instruments.
....This unit is mounted on a metallic structure and may be wall mounted.
This unit has been designed to study a simple lifting mechanism and its use to determine the velocity ratio, mechanical advantages and efficiency.
Intended use:
To transfer liquids in clinical laboratory settings applicable for molecular/PCR & sterile microbiological works.
Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.
Equipped with one oxygen outlet, provided with controllable flow meter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate 10 L/min.
Contains oxygen monitor to verify concentration.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Flowmeter control allows shutting off flow (i.e. 0 L/min) by user.
Noise level <60 dB(A).
Digital meter that displays cumulative hours of device operation.
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.
Electrical characteristics
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.
Casing and environment
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
The unit includes internally and externally mounted filters for cleaning the air intake.
Unit weight <27 kg.
Material: Austenitic steel (non-quenched, non-magnetic steel).
To dilate the vagina to examine the vaginal canal and cervix.
Speculum, vaginal, self-retaining.
Double blade with a screw mechanism to keep the blades open.
Austenitic steel composition: 16 - 18% chromium; 10 - 14% nickel; 2 - 3%molybdenum.
Blade length: approx. 75 mm.
Blade width: approx. 20 mm.
Reusable.
To measure the mid upper arm circumference for rapid screening of nutritional stauts of children. Target population: Malnourished children or those at risk, aged 6-59 months.
....Used as a middle school physics force line to the electric field in the field of the size and direction of the image to express. The demonstration board adopts the "372" material with good transparency. Products is composed of five pieces of electric field line demonstration board, respectively for single point electrode demo board, two point electrodes demo board, parallel plate electrode demo board, an annular electrode demo board, pointed conductor demo board. The shape and size of the five demonstration boards are 108 * 90 * 6.5mm.
....It is used to do experiments in primary school science: the atmosphere has pressure, the atmospheric pressure come from all directions and the application of atmospheric pressure.
....Electromagnetic Suit
....Standards not harmful to the environment or to worker safety
Preservative used enhances stability
Biodegradable, safe and non-toxic
Pre-diluted
Do not include formazin
Ready and easy to use.
Industrial Machines Control Assembly Training Stand Kit
....The two-stage gear unit kit contains all the parts required to construct the gear unit. All parts are clearly laid out and well protected in a sheet-steel tool box. Small parts are supplied in a box with a transparent lid. This assembly exercise permits wide-ranging and, above all, interdisciplinary work to be carried out by the students. It consists of a spur gear stage as its input, with a downstream worm gear stage (multistage gear combination). The fit seatings of the gear unit are designed to allow the complete assembly process to be carried out by hand. This, in conjunction with students working in an independent capacity, as well as developing team working skills, ensures that the unit serves as an excellent learning tool. The project unit is particularly well suited to action-based teaching.
....A bench top service unit designed to interface to a range of heat transfer accessories.
Provides a drive signal for a proportioning solenoid valve used for flow control.
Provides a control signal to a variable speed blower used for generating airflow.
Provides a variable, stabilised 0-24V DC supply to the heater of the heat transfer accessory, with a current capability of 9A.
10 temperature inputs and conditioning circuits for K-type thermocouples:
9 off, 0-133°C, resolution <0.1°C
1 off, 0-500°C, resolution <0.15°C
A comprehensive instruction manual describing how to carry out the laboratory teaching exercises in non-steady state heat transfer and their analysis as well as assembly, installation and commissioning is included.
Outputs can be controlled manually from the front panel, or controlled by the software from a user supplied PC.
Instrumentation inputs for heater voltage, heater current, air flow, water flow, radiation and light meter.
Integral USB interface, and educational software for all accessories.
A centrifugal pump is mounted integrally in the framework and is connected to the filter inlet via a throttle valve and pressure gauge.
A fully self-contained plate and frame type filter press constructed entirely in stainless steel.
Filter surface area is 0.22m² and solids holding capacity is 1.5 litres.
A back pressure valve is located at the filter outlet.
The filter pack is made up of four plates and four frames, which will accept a dressing of seven filter sheets 200mm x 200mm.
The filter pack and sheets are compressed manually using a hardened steel screw thread.
The Compression Ratio can be changed without stopping the engine and without altering the combustion chamber geometry by means of a specially designed tilting cylinder block arrangement both during gasoline running and during Diesel running. Computerized Variable Compression Ratio Multifuel Engine Test Bed allows to perform experiments concerning this kind of engines. The unit consists of single cylinder, four stroke, Variable Compression Ratio (VCR) engine connected to eddy current type dynamometer for loading. Setup is provided with necessary instruments for combustion pressure and crank-angle measurements. The test bed includes a stand-alone panel box consisting of air box, two fuel tanks for duel fuel test, manometer, and fuel Measuring unit, transmitters for air and fuel flow measurements, process indicator and engine indicator. Rota meters are provided for cooling water and calorimeter water flow measurement. These signals are interfaced to computer through engine indicator for pv diagrams. Provision is also made to interface airflow, fuel flow, temperatures and load measurement.
....