Features:
Specially designed shaper machine for increased-production, precision Performance and Deep cut.
Selected special alloy steel used for screws and other steel parts.
Naturally Seasoned Casting.
Quick Return Motion.
Heavily cross ribbed, Robust and sturdy construction ensure free working.
Fully Hand Scrapped.
Simulation model of a forced air gas burner and all burner operating states
Important electrical monitoring points on burner accessible via lab jacks and measuring bridge connectors for fault analysis
Fault simulation: 9 fault switches in lockable box
Additional actual system components: flame safeguard, gas pressure and air pressure control devices, ignition transformer, thermostat, safety temperature limiter, gas solenoid valves, fan motor, emergency switch heating system.
Frame Bench And Floor mounted
....The program covers adjusting brakes, replacing hoses and tubes, servicing master cylinder. Each trainer is large enough to allow two students to be active while learning hands on automotive skills. The hands-on program offers in-depth training in the areas of servicing replacing parts. Power Boost Drum And Disc Brake Trainer has both drum and disc brakes mounted on a welded steel chassis for bench top assembly.
Features:
New and Recycled Drum/Disc Brakes
Powder-Coated Frame
Operating Hydraulic System
Courseware Includes: Instructor Guide, Student Manual, and Service Manual Information.
Includes: Power Assist, Parking Brake, Electrical Circuits and Wheel Bearings
Real World system Skills and Knowledge.
PCR reaction tube to be used on most standard Thermocyclers, RT PCR platforms, DNA Sequencers.
....Material: Austenitic steel (non-quenched, non-magnetic steel).
To spread and open the posterior wall of the vagina to visualize the uterine cervix.
Static function instrument: vaginal speculum.
With weight which fits on the shank of the blade.
Austenitic steel composition: 18 to 20% chromium, 8 to 10% nickel.
Blade width: approx. 38 mm.
Blade length: approx. 80 mm blade.
Total length: approx. 24 cm.
Reusable.
Clear turbidity standards are recognized by the primary stnadard for the calibration of turbidity meters online and in the laboratory for drinking water analysis.
Clear turbidity standards are traceable to NIST Primary Standards on account of their consistent particle size and photometric accuracy via UV-VIS spectroscopy.
Each lot is normalized to historical lots which were formulated to dilutions of 4000 NTU Formazin.
Function Generator 40MHz, 2 channel Electronic Engineering Lab
....The kit contains all the parts required to assemble a functional lever shears. The graphic symbolises standard and production parts, and represents fixed and moving connections differently. All parts are precision-manufactured on CNC machines and feature standard engineering tolerances and surface finishes. The parts are clearly laid out on a base plate. They are grouped into individual assembly sequences. The base plate is covered with a transparent cover panel on which a graphical representation of the assembly structure is printed. Multiple trays are stackable, providing for space-saving storage. The surfaces of the finished parts have a gunmetal finish to prevent corrosion.
....The self-sufficient unit allows to perform experiments on water cooling by using Three interchangeable cooling towers having packings with different heat exchange surface.
Electrical centrifugal fan, 0 to 2000 m3/h, for air circulation, with shutter.
Chamber for air distribution.
Heater for air warming up.
No. 3 towers, 150 x 150 x 600 h mm, made of transparent Plexiglas in order to allow full visibility of the water flow.
Water circulation pump, 30 W, fitted with regulation by-pass.
Turbine type electronic flow rate transducer.
Feeding, signal conditioning and A/D conversion unit.
Transparent water collection tank, with 2 kW electrical heating resistors, fitted with thermostat and level control.
Transparent calibrated tank to compensate the water loss due to evaporation, 10 l capacity
Electric control board.
Analysis and data acquisition software for Windows.
Identification of equipment comes with multiple motors and can support for a variety of experimental. The structure of the electric control line components is plank and hanging box: Equipped with a variety of electrical lighting circuits as single-phase watt-hour meter, dimmer switch, incandescent, fluorescent, Single switch, sockets and electrical control low-voltage such as Leakage circuit breakers, sensor switch, touch switches, time relay, relay, thermal relay, voltmeter, ammeter, buttons, lights, fuses, current transformers, contactors, limit switch, switch, and three-phase four-wire active energy meter, three-phase four line reactive power meter and so on.
....The mixers are equipped with a manually controlled discharge opening situated on the bottom part of the pan, for direct unloading of the mixture into a wheelbarrow or suitable container. Used to prepare concrete specimens or mixtures, these pan type mixers ensure a uniform efficient fast mixture action. The pan and the mixing gears have big thickness ratio, the gears are from hardened and rectified steel, and the motor reducer is in oil-bath with Gleason conical coupling. They are of easy and practical utilisation suitable for laboratory and field purposes. The mixing blades and paddle can be adjusted in height; they are manufactured from special quality hardened steel to resist wear.
....With Taiwan diamond grinding wheel, only one piece can complete all procedure.
It can be equipped directly with an accurate angle and long service life.
It is the special grinder for ball end mill.
Grinding is accurate and rapid, easy operation, with no skill requirement to grind.
Theoretical topics:
Familiarization with DC motor connection types
Familiarization with stepper motor circuits
Types of electric motors
Position control with DC motor
Bi directional H bridge DC motor control circuit
Familiarization with unipolar/bipolar/bifilar/multi-phase stepper motors
Familiarization with AC motor circuits
Main characteristics of DC motor driving systems
Advantages and disadvantages of synchronous motors
Comparison between stepper motor and DC motor
Speed variation in motor controls.
Fault simulation
Demonstration of the function of safety fittings in a closed water circuit with circulating pump and expansion vessel: air separator, quick-action ventilating valve, safety valve, flow switch, pressure reducing valve
Investigation of heating safety fittings
Electrical heater for thermal safety fittings: temperature controller, thermal discharge safety device
Demonstration of the function of safety fittings using compressed air: thermostatic valve, safety Pressure cut-out, safety valve, temperature controller, thermal discharge safety device.
Equilibrium Of A Beam Apparatus
....The Hybrid Demonstrator Trainer includes a Hybrid engine, a battery and an Electronic Control Unit, several meters showing power flow between the units, a brake switch and a potentiometer mimicking the accelerator pedal. The system can also be used to show the effects of regenerative braking. Two models are available: a bench top version and a panel mounted version. The controls the system to show students how the power is routed in a hybrid depending on the State of Charge of the Battery, and to allow them to make measurements on the engine performance under different load conditions.
....PCR reaction tube to be used on most standard Thermocyclers, RT PCR platforms, DNA Sequencers.
....Handheld, battery powered device that measures the oxygen concentrationin a flow of gas from a medical gas source or, with adapters, through a medical gas-flow device such as a ventilator or anaesthesia system, or within an environment such as oxygen hood and infant incubator.
Operational characteristics:
Handheld oxygen analyzer for continuous measurement of the oxygen concentration from a medical gas source and in an environment.
Suitable for measuring gas supply with pressure up to 50 psi (344 kPa).
Response time: ≤ 20 s.
Electrochemical cell oxygen sensing technology.
O2 resolution: 0.1 %.
O2 measurement includes the range 0.0 - 100%.
O2 accuracy: within ± 3 %.
Warm-up time: none required
Display visualizing O2 concentration, system messages and battery status.
Internal calibration timer (weekly); alerts the operator, using a calibration icon on the LCD display, to perform a unit calibration one week after previous calibration.
Low and high oxygen concentration alarm system, with flashing LED and audible indication of alarm conditions.
Replaceable oxygen sensor cell, expected sensor life >1,500,000 O2% hours over 2 years in typical applications.
Calibration and self-test mode, one point calibration 20.9% or 100%.