Sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line. The set-up consists of different pressure measurement devices fitted in a pipe line, in which an Orifice is fitted to create the pressure difference.
Learning Objects/Experimentation:
To measure the pressure and pressure difference by pressure gauge, single column manometer, U Tube manometer & Inclined tube manometer.v
To demonstrate the working of different pressure measuring devices.
Requirment For Operation:
Water Supply (Initial fill)
Floor Drain required.
Electricity Supply: Single phase, 220 VAC, 50 Hz, 5-15 amp.
Combined socket with earth connection.
Mercury (Hg) for manometer (750 gm).
Floor Area Required: 1.5 m x 0.75 m.
The hydraulic system applies either a tensile or compressive loading to specimens. Extension of the specimen is monitored using an extensometer for work on stress/strain curves and the Modulus of Elasticity. This Universal Material Tester is a bench top unit for training purposes. The applied force to the specimens is created using a digital pressure sensor and shown on the Digital Interface supplied. An elongation sensor is also supplied for use in bending, compressive and shear testing. Simple operation and robust construction make the unit suitable for student experiments. The round threaded tensile specimens are installed between upper and lower fixings using the mating threads in each fixing. A wide variety of options are also available. Data Acquisition Software is supplied as standard to enable the test parameters to be captured, displayed, reviewed and printed.
Experimental Capabilities:
Tensile Strength Percentage Elongation
Tensile and Compressive testing Recording of stress-strain diagrams Modulus of Elasticity testing.
Rectangular mosquito net, polyethylene 120-150 DENIER, treated with WHO PQ qualified insecticide, colour white/blue/green, alternative dimensions.
....Intended use:
Various clinical laboratory usage conditions including Sample/reagent preparation, centrifugation, storage.
Blood collection for clinical laboratory tests.
Capped, with a needle-pierceable vacuum seal.
Blood collection vacuum tube.
Material: clear nonfragile PET plastic and leak-proof rubber cap.
Plastic shielded rubber cap to protect personnel from direct contact with blood.
Applicable for automated analyzers.
Pen/Marker writable label space.
Blood draw volume 4.0ml.
Additive EDTA anticoagulant.
Standard color-coded cap.
Cold box, Long term vaccine storage.
Storage capacity: 5.4L
Operating Ambient Temperature: +43°C
Vaccine storage Temperature: +2°C to + 8°C
Cold life at +43°C: 35 Days.
Vaccine storage capacity: 98.5 L
Volume category: >/= 60, <120L
Refrigerant: R600a, 45 grams
Energy consumption, stable running (kWh/24 hours): 1.23
Equipment operating voltage and frequency: 220-240 Volt, or 100-127 Volt and frequency 50Hz or 60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF- Grade A.
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Vaccine storage capacity: 100L
Volume category: >/= 60, <120L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 135 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Remote Temperature Monitoring (RTM) system for real time monitoring of storage conditions at different levels of the vaccine cold chain: (a) with data access, setup of alarm thresholds and setup of alarm recipients through internet accessible dashboard (b) with automatic transmission of data to a server (c) with integrated audio-visual alarm (d) capable of alarm notifications via SMS, email and/or iOS & Android mobile applications (e) configurable to suit specific applications and scalable to allow for the later installation of additional temperature monitoring products and/or storage facilities.
....Capacity: 828L
Cabinet Type: Upright
Volume Category: ≥ 600 <900L
Operating ambient temperature: +10 °C - +32°C (Temperate zone)
Storage temperature: up to-86°C
Adjustable cabinet temperature set point -40°C to -86°C
Power requirement: 220-240V/50Hz.
Armband, cloth.
Material - 220 gsm 100% washed cotton twill.
The material is color-fast, durable and easy to wash.
Adjustable Velcro closure consisting of two horizontal Velcro strips;
length 120mm x width 30mm; sewn along the outer side of the armband.
A third vertical Velcro strip sewn on the underside of the armband,
height 80mm x width 30mm
Color: 100% Cyan Blue
The colour is durable and does not bleach easily in strong sunlight.
There is no leaching of colour when the armband comes into contact with water.
Size: length 420mm x height 80mm.
Volley-ball net, official size 9.5 x 1m with minimum 100mm nylon mesh, thread size minimum 2mm; nylon headband, sides and bottom finished with heavy over lock stitch, 3mm steel cable; without standards or posts.
....Electronic foetal monitoring (EFM) provides graphic and numeric information on foetal heart rate (FHR) and maternal uterine activity (UA) to help clinical personnel assess foetal well-being. Foetal monitors can also provide documentation of the foetus’s condition that could be useful in the event of litigation. During labour, the FHR often exhibits decelerations and accelerations in response to uterine contractions or foetal movements; certain patterns are indicative of hypoxia. Examination of these patterns, the baseline level, and variability characteristics can indicate the need to alter the course of labour with drugs or perform an operative delivery (caesarean section or forceps delivery) if corroborated by other clinical evidence.
Antepartum monitors are used to monitor the foetus’s development, movement, and FHR patterns in utero. They also are often used in the hospital for high-risk mothers who are hospitalized before term for observation or treatment not in conjunction with labour. Antepartum monitors have only external monitoring capabilities, such as ultrasound and external UA, and are typically used in the physician's office or clinic.
Foetal baby, with umbilical cord and placenta.
Full size, flexible term foetus with lifelike features
Umbilical cord and placenta present for training in cord ligation
Realistic placenta for training in placenta expulsion exercises
With smooth, soft skull containing anterior and posterior fontanelles for training in realistic delivery,
Can be used in training of Vacuum deliveries
Should fit into advanced childbirth simulator.
Basic container for nursing and surgical care.
Material: Austenitic stainless steel.
Austenitic stainless steel composition: 18-20% chromium, 8-10% nickel.
Reusable.
Contaner, round.
Smooth surface.
Capacity: approx. 170 to 190ml.
Inner diameter: approx. 75-85 mm.
Height: approx. 36-48 mm.
Thickness: approx. 0.75-0.85mm.
The device comes without a heating source and can be heated through a kerosine stove, electrical heater or even an open fire. A device designed for total elimination and/or inactivation of microorganisms from medical devices and related products using pressurized steam (i.e., moist heat) as the sterilizing agent; it is used for products non-sensitive to high temperature, water, or steam. It includes a treatment chamber with an inner container, it may be intended to sterilize wrapped and/or unwrapped devices.
....To dilate the cervix of the uterus in order to make room for the insertion of instruments.
Static function instrument: uterine dilator.
Double ended with round, smooth, atraumatic ends.
Material: Austenitic steel (non quenched, non magnetic steel).
Austenitic steel composition: 16 - 18 % chromium; 10-14 % nickel; 2-3 % molybdenum.
See Martin Catalogue no. 24 Ref: 32 430 82.
Provided in sets of 8 (16 dilators).
Reusable.
Sizes: 3 - 4 mm to 17 - 18 mm diameter in canvas roll.
Calibration control vial for portable fluorometer to determine quantity of Vitamin A content in foods and biological fluids.
....Soft Armour
Equipped with detachable collar, adjustable shoulders, deployable groin protector and rear extraction grab strap (for speedy evacuation of injured/ casualties), detachable comfort lining. Pullover type with Velcro-fitted strap openings to enable maximum movement of the torso and multiple adjustments to ensure snug fitting. Fitted with front, rear, and side external pockets for insertion of hard ballistic plates.
Inner shell manufactured in suitable material for user comfort and hygiene, which also permits ease of laundering or other way to keep material in clean and hygienic state, includes clear plastic ID sleeve. Outer carrier comprising an outer shell utilizing a robust fabric appropriate for the operational requirements, back coated with polyurethane or similar material (for moisture and mildew resistance), and to include additional finishes for water repellency. Black webbing to attach accessories.
Standard equipment:
Supplied with helmet
Engine (124 cm3):
Stroke cycle: 4
Number of cylinders: 2
Power: 17KW at 8500 rpm
Starter: Electric
Fuel tank capacity: 12 litres
Maximum speed: 120 km/h
Suspension:
Front: Telescopic fork with integrated shock absorbers
Rear: Mono shock suspension system
Transmission:
5 gears
Drive covering: Open