Anaerobic degradation of organic substances
Temperatures in the stirred tank and the uasb reactor can be controlled
Control of the pH value in the UASB reactor
Separate supply unit with tanks for raw water and treated water
Single stage or dual stage operation mode
Stirred tank with secondary clarifier
Uasb reactor with separation system.
This unit is composed of:
Two outer discs made of aluminum.
Torque transmission is accomplished by mating drive keys of the central disc, located on opposite sides and oriented 90 degrees apart, with the slots of the outer discs. A central disc made of acetal, located between both outer discs. It acts as the torque transmitting element.
Both outer discs are mounted in two rotary elements with a graduated disc to read the angle.
Bench-top unit mounted on a structure of anodized aluminum profiles, with painted steel panel, and with legs.
....An inverted aluminium T-beam is mounted between two simple supports on knife edges. The load onto the T-beam is applied using a fine screw jack mechanism with integral load cell. A standalone experiment for determining the bending stresses and strains across the surface of a T-beam. The load cell arrangement and supports create a three (3) point loading.
These strain gauges are paired with temperature compensation dummy gauges for output stability. A number of precision strain gauges are arranged on the T-beam specimen. Each strain gauge pair is numbered for accurate connection to the Interface.
The has been designed and manufactured to incorporate all current safety standards.
The refrigerant used complies with anti-pollution legislation.
A Domestic Air Conditioning Assembly Kit for diagnosing problems associated with refrigeration circuits and air conditioning systems.
The kit comes pre-filled with refrigerant.
Training Objectives:
Interpretation of diagrams and association with their objective
Measurement of wind speed
Identification of the components and association with their function
Analysis of the operation of the installations once assembled
Assembly of the proposed installations
Analysis of the behavior of the wind turbine.
Intended use:
PCR plate to be used on most standard Thermocyclers, RT PCR platforms, DNA Sequencers.
Vaccine storage capacity: 1.04 liters
Cold life at 43°C without openings: 32 hrs 07 min
Supplied with 3 x 0.6-liter icepacks (Bmedical WP 0.6L) as a standard.
With lid and shoulder strap
Weight fully loaded: 7.6 kg.
Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.
Provides a continuous, variable flow of concentrated oxygen 93% (±3%) derived from room air, to a maximum rate 8 L/min.
Equipped with a single oxygen outlet provided with controllable flowmeter.
Audible and/or visual alarms for low oxygen concentration (<82%) and power supply failure.
Contains oxygen monitor to verify concentration.
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter (details under RELATED PRODUCTS).
Audible and visual alarms for high temperature and pressure failure.
Power efficiency ≤ 70 W/LPM.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting.
Flowmeter continuously adjustable, with markings of at most 0.5 LPM intervals.
Noise level <60 dB(A).
CASING AND ENVIRONMENT
Oxygen outlet to be securely mounted and sheltered.
The unit includes internally and externally mounted filters for cleaning the air intake.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Case to be hard, to be cleanable with standard hospital cleaning materials.
Whole unit to be movable with four wheels.
ELECTRICAL CHARACTERISTICS
Electrical power requirements to be locally compatible.
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers or replaceable fuses.
230 Volt, 50 Hz, 2.1 amps (110 Volt units available upon request)
Mains power cable to have length ≥ 2.5 m.
Long cuff gloves for gynaecological and obstetric procedures to protect both patient and medical staff from cross-contamination. Gynaecological gloves are sterile and strictly SINGLE USE.
Gloves, gynaecological, latex, powder-free, size: small, sterile, single use, pair.
Ready-to-use Supplementary Food (RUSF) is a food supplement intended to be used as part of a nutritional program, to treat moderate acute malnutrition (MAM) for children over 6 months, for a period of 2-3 months. Ready-to-use Supplementary Food (RUSF), spread, for the management of moderate acute malnutrition, 100g per sachet, 150 sachets per carton. One sachet per day is the recommended dose of RUSF and provides approximately 535kcal. This product is not a breast-milk replacer. RUSF is intended to be eaten directly from the package with no dilution, mixing or cooking. RUSF is a fortified, stabilised lipid-based paste or spread that is individually packaged into sachets. RUSF is generally made with heat treated oil seeds, pulses or cereals together with sugar, milk powder, vegetable oils, vitamins and minerals.
....Burglar Alarm Circuit Equipment Kit
....It can measure the instantaneous wind speed, average wind speed, instantaneous wind level, average wind speed level, the corresponding wave higher parameters and data latch function.
Composed of the wind speed sensor and the hostpanel with LCD display and function keys.
Biological Microscope Demonstration Device
....Thermometer Bracket
....A small compressor provides a means of adjusting the pressure of the test gas above and below atmospheric pressure. The compressor is mounted on the base board and controlled by a panel mounted switch.
Two sealed glass cylinders with access valves are mounted on a base board and connected via a tube. The measuring cylinder is fitted with a compound gauge designed to measure the gas pressure both above and below atmospheric pressure. One cylinder performs the measuring function and the other is used to pressurise the volume of gas contained above oil in the measuring cylinder.
A pressure switch and relief valves ensure operator safety.
The height of oil and hence the volume of gas in the measuring cylinder is measured using a graduated scale. A thermometer in the measuring cylinder allows the temperature of the gas in the measuring cylinder to be determined.
Controls Technology Double Sided A Frame Bench Upgrade system includes a hose rack, an A-frame assembly, a bench manifold assembly, a bench manifold assembly with valves, a bench manifold hose assembly, and an installation guide.
Controls Technology Double Sided A Frame Bench Upgrade
Controls Technology Double Sided A Frame Bench Upgrade allows for an additional Basic Hydraulics Learning System to be used for simultaneous hydraulic work on both sides of the bench. This system upgrades the Controls Technology Learning System Basic Hydraulics to the Double Sided A Frame Bench with Two Hydraulic Manifolds. The bench can also accommodate up to two additional hydraulic options or pneumatic panels.
The Electrical Fabrication Learning System includes a workstation, wiring components, storage case, hand tool package, electrical consumable package, electrical accessories, and student curriculum in print, instructors assessment guide, and installation guide. Electrical Fabrication Learning System teaches students skills that are commonly used by electricians, technicians, and engineers in todays industry. Installing, operating, repairing, or designing equipment for modern industry requires fundamental knowledge of electrical wiring and components. Optional interactive multimedia extends the learning opportunity as well as allows students to learn in the style they need. Students will gain expertise in key skill areas such as basic electrical system wiring, interpreting wire installation plans, handling non-metallic cable, installing basic components such as switches, outlets, and lighting, and connecting electrical services.
Features:
Safety Emphasized at All Levels
Optional Interactive Multimedia
Hands-On, Job-Ready Industry Skills
Student Reference Guide.