GFS Chemicals Linear Calibration SetsHighly accurate, stable and reproducible standards for calibrating turbidimeters and nephelometers.
Designed for 90° white light turbidimeters.
Ready to use — no mixing or dilution required
Nontoxic and won't settle out of suspension
Guaranteed accuracy within 1%
Consist of polymer microspheres suspended in a pure, aqueous medium
Uniform in particle size distribution to ensure consistent light scattering and precise enough to permit calibration down to and including 0 NTU.
Indoor Solar Energy Training System Set Electronic Engineering Lab
....Lab Stereo Microscope
....A radiation shield may be raised or lowered over the centrally mounted thermocouples to investigate the effects of shielding.
A small scale bench top accessory designed to experimentally investigate how measured temperatures can be influenced by the effects of radiation, temperature sensor design and surface finish.
The circular duct is mounted on the discharge from a centrifugal fan. Air from the fan is blown through the duct past the temperature sensors at a controlled velocity of between 0 and 8m/s. The air velocity is measured by an in duct anemometer.
An additional temperature sensor records the temperature of the inside of the heated duct adjacent to the centrally mounted thermocouples.
Three temperature sensors of different form and surface finish are mounted centrally in a circular stainless steel duct that is surrounded locally by an electrical heater.
The Intermediate Hydraulics Learning System includes directional control valves, relief valves, a flow control valve, a check valve, and an accumulator. Learning systems use industrial-grade components displayed on hand-welded, painted and silk-screened panels, and workbenches made from top-flight materials. This approach to curriculum is signature: reinforce both theory and practice to produce a well-rounded understanding of the topic. Intermediate Hydraulics Learning System introduces advanced hydraulic components explains how each works, and then shows how they relate to real-world applications in elevators, punch presses, backhoes, and many more. The skills and principles offered in build on the fundamentals taught by the Basic Hydraulics learning system, but also lead to additional, more advanced learning systems such as Advanced Hydraulics and Electro-Hydraulics. This precise attention to quality and detail ensures a tough, visually appealing, user-friendly design that will last for years and help learners gain experience with components theyll actually see on the job. Learners will be able to understand concepts like pressure intensification and cylinder regeneration while also being able to operate, install, design, and troubleshoot hydraulic components.
Features:
Pre-Mounted Components for quick setup
Plug-in Quick Disconnect Component Connections
Industrial Standard Components
Portable
Multimedia Curriculum Available
Student Reference Guide.
AC DC Electrical Learning System training system covers industry-relevant technical skills including how to operate, install, design, and troubleshoot basic AC and DC electrical circuits for various applications. The AC DC Electrical Learning System includes a bench top-mount workstation, lamp module assembly, pushbutton switch module assembly, selector switch module assembly, circuit breaker module assembly, handheld digital meter, and much more! Learners will use these components to study topics such as manual input devices, voltage measurement, lighting circuits, voltage dividers, and troubleshooting. AC DC Electrical Learning System explores the fundamental concepts of AC and DC electrical systems. Learners will see how electricity is used for power and control in industrial, commercial, agricultural, and residential applications. This system uses industrial quality components for durability to stand up to frequent use and to help learners become better prepared for what they will encounter on the job.
Features:
Features industrial components
Integrated Workstation
Covers skills used in industrial, commercial, agricultural, and residential applications
Effective Component Inventory
Emphasizes safety
Offers many hands-on skills
Multimedia Curriculum Available
Student Reference Guide.
Compact, mobile, easy to install
Temperature output for data logging
Rapid heating of product to 140°C in less than one second
Reflected power monitor for fine tuning of the microwave system
Various holding tubes
Versatile
Product temperatures up to 160°C
Dielectric heating with microwave energy.
Hermetic refrigerant compressors have welded sheet steel housing. The drive motor and refrigerant compressor are fitted in this capsule. The motor compressor is suspended by springs in the capsular housing which minimises the transmission of vibration to the capsule body, thereby reducing noise emission. Unlike open compressors, the refrigerant compressor is directly connected to the drive motor and therefore does not require any floating seal.
....The water feeding can be directly connected to the mains and the water circulation is ensured by a pump rated at 0.55 kW. This electric and automatic steam generator is fitted with two separate sets of heating elements for single or double operation.
....The Mechanical Heat Pump consists of a hermetic compressor, an insulated coiled concentric tube water cooled condenser, a liquid receiver, a thermostatically controlled expansion valve and air heated evaporator.
Mechanical Heat Pump components are clearly but compactly arranged in a manner similar to that used for many domestic air-water heat pumps and all are visible from the front of the unit.
The components of the heat pump and its instrumentation are mounted on a high quality ABS plastic panel.
Mechanical Heat Pump is given up to the cooling water and the refrigerant condenses to a liquid before passing to the liquid receiver and then the expansion valve. Slightly superheated Refrigerant vapour enters the compressor from the evaporator and its pressure is increased. This brings about a rise in temperature and the hot vapour enters the water cooled condenser.
Polystyrene cube mould, 200 MM side one gang.
....Technical Features:
Housing are made from M.S. Plate of suitable strength andmounted on heavy base frame. Rolls are made from forged steel and perfectlymachined for accurate result.
For longer life and smooth working of machine, Gun MetalBushes are provide and given sufficient lubrication system A
Bottom roll are fixed and driven by Gears and warm Reduction Gear Box. Top Roll rotates in fixed positions andean be adjusted up & downmanually by adjustable screws.
Machine Application & Usage:
Cone Making & Other Aluminum & Steel Fabrication,Marine & Ship Building, Pressure Vassals, Wind Mills.
Boiler Tank, Air Conditioning Channels, Sheet Metal Cover
Pyramid Type Bending Roller:
Bottom roll are fixed and driven by Gears and warm ReductionGear Box. Top Roll rotates in fixed positions andean be adjusted up & downmanually by adjustable screws.
Bending Process:
Down the top roll and give pressure on the plate. Then start Main motor in clock wise direction till one end of the plate comes over firstbottom roll reverse the motors and get second end on second bottom
Continue above process until you et desired as shown inpicture.
Place the Plate between bottom and top rolls by adjustingtop roll manually.
Bench top unit.
Main metallic elements made of stainless steel.
Diagram in the panel with distribution of the elements similar to the real one.
Unit mounted on an anodized aluminum frame with painted steel panel.
Four interchangeable cams:
One concave cam.
One tangent cam.
Two circular cams with different radii of lateral curvature.
Two steel beams are supplied, each having a different thickness, thus allowing the effect of beam thickness and length on deflection to be studied. Two movable vertical beam supports allow the fixing of knife-edges to their tops to create a simply supported arrangement for the study of Deflections of Beams. Each support can be moved anywhere within the working area of the Universal Frame and Stand and allows a variety of beam spans to be achieved. Apart from the large difference in second moments of area (nearly 1 to 4.5) it will be found that the stiffer beam is more accurate experimentally, while the more flexible beam exaggerates the deflected shape and is visually instructive.
Each clamp can be positioned anywhere along the working length of the beam, and can be quickly and easily removed and re-positioned. A set of calibrated test weights and load hangers creates the loads. Three load hangers supplied ensure a variety of loads can be applied to the Deflections of Beams. Each hanger is attached to the beam via beam clamps.
A bench-top unit for simulating the Air Conditioning System in a Building and studying the operation and control of an air conditioning system installed in a large industrial / commercial building.
....Combined Wind And Solar Power Generation is supplied with a 500W solar simulator that allows the panel to be irradiated and generate power within the laboratory. This allows students to investigate the relative magnitude of incoming solar radiation, relative to power generated.
A small solar panel with nominal 10W output is connected to a battery charge control system. The charge controller can be connected to the supplied 12V deep cycle lead acid battery. The charge controller is also connected to a small wind turbine.
Intended use:
PCR plate to be used on most standard Thermocyclers, RT PCR platforms, DNA Sequencers.
A tool to measure the intensity and frequency spectrum of light sources used for the treatment of hyperbilirubinemia. Irradiance meter to measure the output of blue light phototherapy units for treatment of jaundice.
Suitable for conventional CFL (fluorescent), halogen blue light sources.
Suitable for fibreoptic, and LED light sources.
Designed for frequent disinfection with hospital-grade products.
Portable, handheld model.
Results are available within 5 seconds after commencement of the measurement.
Two models available, one model requires 2 x AAA alkaline batteries, another model has a built-in rechargeable lithium-ion battery.
The sensitivity is equal to or better than: 0.1 µW/cm²/nm.
Automatic zero adjustment at instrument switch-on.
Full batteries allow for 8 hours continues operation for the rechargeable version and 120 hours for the version with 2 x AAA alkaline batteries.
The spectral range for blue light is equal to or better than: 400 – 500 nm.
The spectral irradiance (in wavelength) range is equal to or better than: 0.1 – 150 µW/cm²/nm.
The unit has the following minimal features:
A self-check function.
LCD display clearly visualizing measurement results and other information.
Out of measurement range indicator.
Alarms for detector and/or system failure.
Low battery indicator.
An auto switch-off feature.
Material: Austenitic steel (non-quenched, non-magnetic steel).
Austenitic steel composition: 16-18% chromium, 8-14% nickel, 2-3% molybdenum.
To explore a surgical wound or to explore and/or dilate strictures inside a fistula.
Probe / dilator, straight.
Blunt bulbous shaped ends.
Diameter of the ends: approx. 2 mm.
Length: approx. 145 mm.
Reusable.