Welding Oxygen Cylinder
....Workshop Oxygen Plant Filling Service
....The Oxygen Analyser measures oxygen concentrations from percentage levels to a fraction of parts per million (ppm) in clean gases. The unique cell and heater design gives very fast warm-up times, rapid response, and long sensor life. Packaged on a 19 rack mounting enclosure, it uses a oxygen sensor to provide accurate measurement with minimal interference from other gases.
....High Performance Oxygen Bomb Calorimeter
....Nasal cannula (nasal prongs), device designed for easy administration of oxygen into the patient nose through two small prongs placed in the nostrils, providing comfort for the patient.
The device consists of:
Star lumen main tube to avoid accidental blockage.
Over-the-Ear tubing adjustable
Soft funnel shaped connector to facilitate easy connection to oxygen source.
Adjustable, smoothly finished nasal tips for maximum patient comfort.
Soft twin prongs nasal tips to ensure equal oxygen flow to both.
Length of the oxygen tube: +/-2 m.
Material: Preferably soft and kink resistant polyvinyl chloride (PVC).
Single use.
Non-sterile.
Size selected: Adult
Nasal cannula (nasal prongs), device designed for easy administration o foxygen into the patient nose through two small prongs placed in the nostrils, providing comfort for the patient.
The device consists of:
Material: Preferably soft and kink resistant polyvinyl chloride (PVC).
Star lumen main tube to avoid accidental blockage.
Over-the-Ear tubing adjustable
Soft funnel shaped connector to facilitate easy connection to oxygen source.
Soft twin prongs nasal tips to ensure equal oxygen flow to both.
Adjustable, smoothly finished nasal tips for maximum patient comfort.
Length of the oxygen tube: +/- 2 m.
Size selected: Child
Single use.
Non-sterile.
Nasal cannula (nasal prongs), device designed for easy administration ofoxygen into the patient nose through two small prongs placed in thenostrils, providing comfort for the patient.
The device consists of:
Soft twin prongs nasal tips to ensure equal oxygen flow to both.
Soft funnel shaped connector to facilitate easy connection to oxygensource.
Length of the oxygen tube: +/- 2 m.
Material: Preferably soft and kink resistant polyvinyl chloride (PVC).
Adjustable, smoothly finished nasal tips for maximum patient comfort.
Star lumen main tube to avoid accidental blockage.
Over-the-Ear tubing adjustable
Size selected: Neonate
Non-sterile.
Single use.
The oxygen flow splitter is a device intended to distribute medical oxygen from a source to multiple independent outlets. It can be connected to any low-pressure oxygen source, including concentrators, cylinders and a centralized system, and is suitable for tabletop or wall mounting.
Suitable for cleaning and disinfection with hospital-grade cleaning products.
Inlet port is DISS format.
6 mm barbed outlets.
Flow meter columns are transparent, clearly readable and graduated (metric system).
Equipped with five independent, Thorpe tube flow meters, to measure and regulate the flow of medical gas.
Inlet pressure up to at least 20 psi (138 kPa).
0-2 L/min, accuracy better than 10%, graduation 0.125 L/min or lower.
Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc. A mains electricity powered device that concentrates oxygen from ambient air and delivers the concentrated oxygen in a controlled manner to a patient requiring oxygen therapy, up to 10 L/min.
....Medical gas flow meter (Thorpe tube design) to regulate and measure the flow rate of medical gas supplied to a patient, maximum flow rate 3.5 LPM, for medical oxygen.
Transparent, graduated (metric system) column, shatter resistant polymer certified for medical use.
Graduation shall have over 270 degrees of visibility.
Needle valve and body constructed of brass or aluminium.
Inlet and outlet connectors DISS style, other types of connectors available upon request
Thorpe tube design flow meter using DISS input connector for panel /regulator mounting.
Can be cleaned with damp cloth and a disinfection solution.
Calibrated at 50-55 psi / 345-380 kPa / 3.4-3.8 bar inlet gauge pressure.
Inlet pressure (nominal) > 50 psi (345 kPa / 3.45 bar), peak inlet pressure at least 100 psi (690 kPa / 6.89 bar).
Maximum flow rate when fully opened: 50 L/min (depending on supplied model).
Pressure compensated design to give specified accuracy for whole range of input pressures
Built-in inlet filter (depending on supplied model).
Adjustment knobs to have rough surface to prevent slipping.
Medical gas flow meter (Thorpe tube design) to regulate and measure theflow rate of medical gas supplied to a patient, maximum flow rate 8 LPM,for medical oxygen.
Graduation shall have over 270 degrees of visibility.
Needle valve and body constructed of brass or aluminium.
Calibrated at 50-55 psi / 345-380 kPa / 3.4-3.8 bar inlet gauge pressure.
Inlet pressure (nominal) > 50 psi (345 kPa / 3.45 bar), peak inlet pressure at least 100 psi (690 kPa / 6.89 bar).
Pressure compensated design to give specified accuracy for whole range of input pressures
Built-in inlet filter.
Thorpe tube design flow meter using DISS input connector for panel /regulator mounting.
Can be cleaned with damp cloth and a disinfection solution.
Transparent, graduated (metric system) column, shatter resistant polymer certified for medical use.
Maximum flow rate when fully opened: 50 L/min.
Inlet and outlet connectors DISS style, other types of connectors available upon request
Adjustment knobs to have rough surface to prevent slipping.
Medical gas flow meter (Thorpe tube design) to regulate and measure the flow rate of medical gas supplied to a patient, maximum flow rate 15 LPM, for medical oxygen.
Graduation shall have over 270 degrees of visibility.
Needle valve and body constructed of brass or aluminium.
Calibrated at 50-55 psi / 345-380 kPa / 3.4-3.8 bar inlet gauge pressure.
Inlet pressure (nominal) > 50 psi (345 kPa / 3.45 bar), peak inlet pressure at least 100 psi (690 kPa / 6.89 bar).
Pressure compensated design to give specified accuracy for whole range of input pressures
Thorpe tube design flow meter using DISS input connector for panel /regulator mounting.
Can be cleaned with damp cloth and a disinfection solution.
Transparent, graduated (metric system) column, shatter resistant polymer certified for medical use.
Built-in inlet filter (depending on supplied model).
Maximum flow rate when fully opened: 50 L/min (depending on supplied model).
Adjustment knobs to have rough surface to prevent slipping.
Inlet and outlet connectors DISS style, other types of connectors available upon request.
Medical gas flow meter (Thorpe tube design) to regulate and measure theflow rate of medical gas supplied to a patient, maximum flow rate 5 LPM,for medical oxygen.
Transparent, graduated (metric system) column, shatter resistant polymer certified for medical use.
Graduation shall have over 270 degrees of visibility.
Needle valve and body constructed of brass or aluminium.
Thorpe tube design flow meter using DISS input connector for panel /regulator mounting.
Can be cleaned with damp cloth and a disinfection solution.
Inlet and outlet connectors DISS style, other types of connectors available upon request
Adjustment knobs to have rough surface to prevent slipping.
Calibrated at 50-55 psi / 345-380 kPa / 3.4-3.8 bar inlet gauge pressure.
Inlet pressure (nominal) > 50 psi (345 kPa / 3.45 bar), peak inlet pressure at least 100 psi (690 kPa / 6.89 bar).
Pressure compensated design to give specified accuracy for whole range of input pressures.
Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.
Provides a continuous, variable flow of concentrated oxygen 93% (±3%) derived from room air, to a maximum rate 8 L/min.
Equipped with a single oxygen outlet provided with controllable flowmeter.
Audible and/or visual alarms for low oxygen concentration (<82%) and power supply failure.
Contains oxygen monitor to verify concentration.
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter (details under RELATED PRODUCTS).
Audible and visual alarms for high temperature and pressure failure.
Power efficiency ≤ 70 W/LPM.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting.
Flowmeter continuously adjustable, with markings of at most 0.5 LPM intervals.
Noise level <60 dB(A).
CASING AND ENVIRONMENT
Oxygen outlet to be securely mounted and sheltered.
The unit includes internally and externally mounted filters for cleaning the air intake.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Case to be hard, to be cleanable with standard hospital cleaning materials.
Whole unit to be movable with four wheels.
ELECTRICAL CHARACTERISTICS
Electrical power requirements to be locally compatible.
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers or replaceable fuses.
230 Volt, 50 Hz, 2.1 amps (110 Volt units available upon request)
Mains power cable to have length ≥ 2.5 m.
Optical Dissolved Oxygen Sensor
....Oxygen Gas Digital Sensor
....Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.
Equipped with one oxygen outlet, provided with controllable flow meter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate 10 L/min.
Contains oxygen monitor to verify concentration.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Flowmeter control allows shutting off flow (i.e. 0 L/min) by user.
Noise level <60 dB(A).
Digital meter that displays cumulative hours of device operation.
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.
Electrical characteristics
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.
Casing and environment
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
The unit includes internally and externally mounted filters for cleaning the air intake.
Unit weight <27 kg.
OXYGEN PRODUCTION
Provides a continuous, variable flow of concentrated oxygen 93% (±3%) derived from room air, to a maximum rate 8 L/min.
Audible and visual alarms for high temperature and pressure failure.
Power efficiency ≤ 70 W/LPM.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting.
Contains oxygen monitor to verify concentration.
Equipped with two oxygen outlets each provided with controllable flow meter.
Audible and/or visual alarms for low oxygen concentration (<82%) and power supply failure.
Flowmeter continuously adjustable, with markings of at most 0.5 LPM intervals.
Noise level <60 dB(A).
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter.
ELECTRICAL CHARACTERISTICS
Mains power cable to have length ≥ 2.5 m.
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical power requirements to be locally compatible.
230 Volt, 50 Hz, 2.1 amps (110 Volt units available)
Electrical protection by resettable circuit breakers or replaceable fuses.
CASING AND ENVIRONMENT
Case to be hard, to be cleanable with standard hospital cleaning materials.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Oxygen outlet to be securely mounted and sheltered.
Whole unit to be movable with four wheels.
The unit includes internally and externally mounted filters for cleaning the air intake.
Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate of 5 L/min.
Contains oxygen monitor to verify concentration.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.
Flowmeter minimum flow rate of 1 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flowmeter stand (details under RELATED PRODUCTS).
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Equipped with one oxygen outlet, provided with controllable flowmeter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Noise level <50 dB(A).
Contains flow limiter to prevent overdrawing oxygen flow beyond rated maximum flow rate.
Casing and environment
The unit includes internally and externally mounted filters for cleaning the air intake.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
Unit weight <27 kg
Electrical characteristics
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.