Flow splitter,for oxygen concentrator

Product Code: LBNY-0017-2200021 - (Flow splitter,for oxygen concentrator)

The oxygen flow splitter is a device intended to distribute medical oxygen from a source to multiple independent outlets. It can be connected to any low-pressure oxygen source, including concentrators, cylinders and a centralized system, and is suitable for tabletop or wall mounting.
Suitable for cleaning and disinfection with hospital-grade cleaning products.
Inlet port is DISS format.
6 mm barbed outlets.
Flow meter columns are transparent, clearly readable and graduated (metric system).
Equipped with five independent, Thorpe tube flow meters, to measure and regulate the flow of medical gas.
Inlet pressure up to at least 20 psi (138 kPa).
0-2 L/min, accuracy better than 10%, graduation 0.125 L/min or lower.

....


   

Oxygen concentrator/SET

Product Code: LBNY-0017-2200022 - (Oxygen concentrator/SET)

Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc. A mains electricity powered device that concentrates oxygen from ambient air and delivers the concentrated oxygen in a controlled manner to a patient requiring oxygen therapy, up to 10 L/min.

....


   

Oxygen concentrator, 8LPM, single flow

Product Code: LBNY-0017-2200032 - (Oxygen concentrator, 8LPM, single flow)

Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.
Provides a continuous, variable flow of concentrated oxygen 93% (±3%) derived from room air, to a maximum rate 8 L/min.
Equipped with a single oxygen outlet provided with controllable flowmeter.
Audible and/or visual alarms for low oxygen concentration (<82%) and power supply failure.
Contains oxygen monitor to verify concentration.
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter (details under RELATED PRODUCTS).
Audible and visual alarms for high temperature and pressure failure.
Power efficiency ≤ 70 W/LPM.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting.
Flowmeter continuously adjustable, with markings of at most 0.5 LPM intervals.
Noise level <60 dB(A).

CASING AND ENVIRONMENT
Oxygen outlet to be securely mounted and sheltered.
The unit includes internally and externally mounted filters for cleaning the air intake.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Case to be hard, to be cleanable with standard hospital cleaning materials.
Whole unit to be movable with four wheels.

ELECTRICAL CHARACTERISTICS
Electrical power requirements to be locally compatible.
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers or replaceable fuses.
230 Volt, 50 Hz, 2.1 amps (110 Volt units available upon request)
Mains power cable to have length ≥ 2.5 m.

....


   

Oxygen concentrator, 10 LPM, single flow

Product Code: LBNY-0017-2200050 - (Oxygen concentrator, 10 LPM, single flow)

Oxygen concentrators are not suitable to be used as an oxygen source to other medical equipment providing respiratory support, such as ventilators, CPAP devices, High Flow Nasal Oxygen, etc.
Equipped with one oxygen outlet, provided with controllable flow meter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate 10 L/min.
Contains oxygen monitor to verify concentration.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Flowmeter control allows shutting off flow (i.e. 0 L/min) by user.
Noise level <60 dB(A).
Digital meter that displays cumulative hours of device operation.
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.

Electrical characteristics
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.

Casing and environment
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
The unit includes internally and externally mounted filters for cleaning the air intake.
Unit weight <27 kg.

....


   

Oxygen concentrator, 8LPM, double flow

Product Code: LBNY-0017-2200051 - (Oxygen concentrator, 8LPM, double flow)

OXYGEN PRODUCTION
Provides a continuous, variable flow of concentrated oxygen 93% (±3%) derived from room air, to a maximum rate 8 L/min.
Audible and visual alarms for high temperature and pressure failure.
Power efficiency ≤ 70 W/LPM.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting.
Contains oxygen monitor to verify concentration.
Equipped with two oxygen outlets each provided with controllable flow meter.
Audible and/or visual alarms for low oxygen concentration (<82%) and power supply failure.
Flowmeter continuously adjustable, with markings of at most 0.5 LPM intervals.
Noise level <60 dB(A).
Flowmeter minimum flow rate of 2 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flow splitter.

ELECTRICAL CHARACTERISTICS
Mains power cable to have length ≥ 2.5 m.
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical power requirements to be locally compatible.
230 Volt, 50 Hz, 2.1 amps (110 Volt units available)
Electrical protection by resettable circuit breakers or replaceable fuses.

CASING AND ENVIRONMENT
Case to be hard, to be cleanable with standard hospital cleaning materials.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Oxygen outlet to be securely mounted and sheltered.
Whole unit to be movable with four wheels.
The unit includes internally and externally mounted filters for cleaning the air intake.

....


   

Oxygen concentrator, 5 LPM

Product Code: LBNY-0017-2200052 - (Oxygen concentrator, 5 LPM)

Provides a continuous, variable flow of concentrated oxygen (>82%) derived from room air, to a maximum rate of 5 L/min.
Contains oxygen monitor to verify concentration.
Digital meter that displays cumulative hours of device operation.
Oxygen outlet(s) with 6 mm (¼-inch) barbed fitting and DISS connector.
Flowmeter minimum flow rate of 1 L/min. Lower flow rates may be achieved by a combination of the concentrator and a separately supplied flowmeter stand (details under RELATED PRODUCTS).
Flowmeter continuously adjustable, with markings of at most 0.5 L/min intervals.
Equipped with one oxygen outlet, provided with controllable flowmeter.
Audible and visual alarms for low oxygen concentration (<82%) and power supply failure.
Audible and visual alarms for high temperature, no flow rate and low/high pressure.
Power efficiency < 70 W/L/min.
Noise level <50 dB(A).
Contains flow limiter to prevent overdrawing oxygen flow beyond rated maximum flow rate.

Casing and environment
The unit includes internally and externally mounted filters for cleaning the air intake.
All user-removable filters are cleanable. Cleaning instructions for filters are included in the instructions for use.
Hard case, cleanable with standard hospital cleaning materials.
Whole unit movable with wheels on at least two feet
Unit weight <27 kg

Electrical characteristics
Capacity for safe operation from at least ± 10% of rated voltage.
Electrical protection by resettable circuit breakers, fitted in both neutral and live lines.
Electrical power requirements are locally compatible.
230 Volt, 50 Hz, 3.0 amps (120 Volt units available)
Mains power cable length > 2.5 m.

....


   
Support