An orifice can be screwed into either of the threaded holes and the unused aperture sealed with the blanking plug provided. A scale is mounted on the side of the tank to enable the height of the water above either orifice position to be determined. This arrangement avoids excessive turbulence and enables a steady level surface to be maintained. Two threaded holes are cut into the tank in which to mount the orifice being studied, one in the tank base for 'vertical' discharge, and the other in the tank side for 'horizontal' discharge. The zero of the scale coincides with the centre of the side outlet position. The Orifice sets are used in conjunction with the Inlet Head Tank for the investigation of the flow of water through a horizontal or a vertical orifice. Water is supplied to the tank via a hose connection to the base inlet, and is then distributed within the tank by a vertical perforated sparge pipe. When an orifice is fitted in the horizontal discharge position a Trajectory Profile Hook Gauge can be used to determine the jet profile. Details of both sets of orifices are given as follows.
....Control unit for the powder brake. The speed and the torque are displayed by means of instruments; analogue outputs are also available. It allows measuring the rotating speed and the torque generated by an electrical motor. It also provides the excitation voltage to the brake.
Ranges: 2000 - 4000 - 6000 rpm, with switch
Torque section: 50 division instrument, class 1.5
Ranges: 10 - 20 Nm, with switch
Speed section: 40 division instrument, class 1.5
Power supply section for the brake:
Supply voltage: 230 V, 50/60 Hz
Output: from 0 to 20 Vdc, 1 A.
The group is supplied with manuals which describe all parts of the Gear Pumps Study Unit the installation and utilisation procedures, aswell as many exercises with relative resultsThe gear pump mounted onto the bench is characterized by the possibility of regulating the delivered flow rate, keepingconstant the delivery pressure, changing the rotation speed of the operation electrical motor. The gear pump study unit allows the student to understand and to experiment the oil gear pumps running.
....Most Closed Circuit Wind Tunnels designs are traditional single-return, horizontally arranged circuits. However, any configuration is possible. As with all wind tunnels, exceptionally steady test section flow with close uniformity of velocity is standard. The use of steel for construction offers complete design freedom to meet your unique specifications and needs, such as low overhead clearance or building support columns. Turbulence level is typically below 0.10 percent throughout the full tunnel speed range.
....Electronic conductivity meter with automatic temperature compensation
Circuit for connection with a vacuum pump including check valve
Electronic rpm indicator for the stirrer
Distillation column packed with stainless steel mesh
Overhead condenser
Reactor with a capacity of 3 litres and 1.0 kW electric heater
Stirrer for the reactor, 0 to 400 rpm, with a mechanical seal that is lubricated with silicone oil
Tanks for adding reagents with a capacity of 1 litre
Tanks for collection of distillate with 2 litres capacity
2 electronic temperature indicators
2 thermocouples with pt100 probes protected by stainless steel shield sleeves
Vacuum gauge range 1 to 0 bar .
Emergency stop button
Electrical control panel in main cabinet
Pipe work and valves manufactured from stainless steel.
The imbalance of a rotating machine part may cause harmful vibrations in the entire machine. A familiar example is unbalanced tyres on a car. In rotating machines such as turbines or pumps, vibrations due to imbalance lead to comfort problems or even damage related to overloading. If this balancing is done not on a particular machine but directly on the machine in operation located on-site, it is known as field balancing. These cause annoying and unpleasant vibrations in the steering. This is why almost all rotating parts are balanced.
Learning Objectives And Experiments:
Measure and assess machine vibrations
Static, dynamic or general imbalance
Occurrence of imbalance vibrations
Field balancing in one plane
Field balancing in two planes
Dependence of imbalance vibration on position and magnitude of the imbalance
Basic principles of balancing
Using a computerised vibration analyser
Assessment of balancing quality.
Features:
Single and two-plane balancing
Measurement of imbalance vibrations.
The unit consists of a storage tank on a steel base, a pump, a turbine, a dynamometer, and measuring instruments. The twin nozzles direct water jets to the runner radial blades. Mini Axial Flow Impulse Turbine Test Set is a self contained bench top set for studying the axial flow impulse turbine characteristics under various flow rates and heads.
Experiments:
Power output vs speed for various heads and flow rates.
Torque vs speed at various heads and flow rates.
Racing characteristics.
Efficiency vs speed for a given head and flow rate.
Experiments:
Proportional and proportional plus integral control of servo-system speed
Disturbance cancelling and feed forward control
Response calculation and measurement
Angular position control: proportional control and velocity feedback
Basic tests and transducer calibration
Non-linear system characteristics.
Angular position control and the influence of non- linearities.
It is good for extended or advanced control experiments, and is ideal for student project work. The flexible design of the equipment allows the user to develop many other analysis and control exercises to suit their needs.
Truck Air brake And Trainer requires external air supply to be connected to the rear of the unit and 115 VAC power source. All parts and important lines are clearly labeled, as are the pressure switches and warning light indicators. Truck Air Brake And Trainer is a fully functioning Bendix Truck Air brake system. All components of the Trainer are real truck brake systems (air valves, brake boosters, control devices). All wiring harness connectors are exposed for trouble shooting purposes.
....The Motor Exciter assembly houses two out of balance masses, which when rotated at speed, created a sinusoidal excitation. This excitation motion is transmitted to the test beam, which starts to vibrate. The frequency of vibration changes with the changing speed of the motor. The Motor Exciter is an essential part of the Universal Vibration Apparatus. Motor Exciter primary function is to transmit rotational motion into linear displacement of a beam, and hence force the beam to vibrate at varying amplitudes and frequencies. The Motor Exciter is controlled by the speed control unit. All the connection cables and sockets are factory fitted. A proximity sensor mounted to the rear of the motor gives the signal to the Tachometer. The Motor Exciter is clamped onto a rectangular beam, in the desired position, i.e. onto the beam within Free and Forced vibration module.
....Power supply unit for Three Phase connection with4pole cam mains switch. Three phase indicator lamps. 25A current operated earth leakage circuitbreaker, sensitivity 30 mA.
Switch for simulation of wind or photovoltaic energy power source.
Output through 5 safety terminals:
L1, L2, L3, N and PE.
Inconjunction with our engine cutaway, students can gain a thorough familiarization with engine construction and assembly. The engine stand allows easy positioning of the engine during work. The students can also perform engine inspection. The tear down engine is used for hands-on training for the dis-assembly and re-assembly of engine parts and sections. The stand includes casters that allow convenience in moving the engine as desired
Engine Features:
Fan/Compressor Stages: 1/8
Length(Inches): 75.5
Core / Power Turbine Stages: 2/1
Max Diameter(Inches): 33
Bypass Ratio:2.0
Dry Weight(Lbs.): 725 - 737.
It has a modular design. It may be installed and operated as a roll axis only autopilot, roll and pitch axis, or a roll, pitch, and yaw axis autopilot. Autopilot Trainer is based on a Century 2000 Autopilot. The advanced design provides very smooth and precise corrections in aircraft attitude. Theflexible design provides the economy of expand ability. The complete Century 2000 is a true 3-axes, flight director/autopilot.
System Components:
Roll Axis Control
The complete roll axis autopilot features continuous roll/NAV/voltage monitors, heading select, heading hold, NAV, /LOC/BCanticipative intercept and track automatic soft track, about 45 degree intercept and all angle intercept with HSI.
System Components:
Directional Gyro/Indicator
Roll Servo
Autopilot Computer/Control Unit
Attitude Indicator / Flight Director
Moveable Control Surfaces
Turn & Slip Indicator
Altitude Pre-selector
Autopilot Annunciator
Rate of Climb Indicator
Altitude Sensor
Yaw Servo
Pitch Servo.
Polariscope Frame has integral slides into which fit quarter wave plates and polarisation filters. These plates and filters can be rotated through 90° to vary the colourisation seen by the user.
The Polariscope Frame is a bench top mounted frame which allows the study of stress patterns and photoelasticity resulting from geometrical changes in loaded mechanical models.
The frame can sit on top of a light box or overhead projector. Rubber mounting feet enable it to sit firmly onto the light source.
Experimental Capabilities:
Tensile loading of beams, perforated beams, plates, overlap element
Variation of stress colourisation
Photoelastic analysis of standard mechanical models
Rotational position of wave plate and filters
Analysis of Crane hook under tensile load.
Intended use:
To hold 0.5ml, 2.0ml microcentrifuge tubes/Cryovials, and 15ml tubes in an upright position. To be used in the clinical laboratory setting.
For quick and easy centrifugation of samples in PCR plates, strips, tubes or microplates.
....Blood collection needle holder for use with vacuum tubes, and vacuum tube needles.
For use in clinical phlebotomy.
Material; clear polypropylene plastic
Fits all standard, 13mm, and 16mm diameter vacuum tubes, and all common needle units.
Disposable
Blood collection needle holder.
Vaccine storage capacity 22.5 litres
Cold box, Large, Long range
With hinged lid and carrying handles.
Cold life at 43°C without openings: 128 hours 16 minutes
Supplied with 50 x 0.3L icepacks as a standard.
Weight fully loaded: 48.02 Kg
Volume category: Vaccine storage capacity: 58 L
Energy consumption, stable running (kWh/24 hours): 1.91
Equipment operating voltage and frequency: 220-240 Volt 50Hz /60Hz, or 100-127 Volt 50Hz /60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF- Grade A
Refrigerant: R600a, 68 grams
Prequalified Intermittent Mains Powered Combined Refrigerator and Water-Pack Freezer for storage of vaccines at +2 ?C to+8?C and freezing of water packs.
Vaccine storage capacity: 36 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 40 grams, R600a, 30 grams, R290, 10 grams.