Electric heater with thermostat and dry-running protection
Direct temperature display at heater outlet with bimetallic thermometer
Construction of a temperature control loop
Primary circuit with heater and heat exchanger, connected to water supply of base module
Flow of primary circuit controlled by hand-operated valve
Ready-to-install compact panel assembly
Secondary circuit of heat exchanger connected to laboratory water supply
Heater is either an actuator or a continuous heater
Plate heat exchanger, operating in counter-flow or parallel-current mode.
Material: Needle: Stainless steel conform to ISO 9626-1:1991.
Measurements: External diameter expressed in Gauge and millimetres.
Base and protective cap: medical grade plastic.
Length expressed in inch and millimetres.
Sterile
Disposable.
Size selected: 23Gx1” (0.6x25mm).
Made of stainless steel. Product is effective range of 125 mm, the index value of 1mm, the measuring accuracy of 0.05mm or 0.02mm common vernier caliper with the function of beta, tracking and depth measurement.
....It is used to strengthen understanding addition and subtraction of number and do shopping game in maths teaching. It consists of ten designs in colour.
....Plug type electrical equipment, main switch, ammeter, resistors, diodes, positioner and plug connection line number matching etc.
....The material offers enhanced liquid barrier protection– fabric tested for blood and blood-borne pathogen penetration, chemotherapy drug and hormone permeation and the built-in thumb loops help maintain glove and garment interface.
The gowns are low lint to minimize contamination. Liquid Barrier Gown is bulk-packaged and available in a range of sizes to help ensure comfort.
Liquid Barrier Gowns deliver stringent barrier protection and superior contamination control for your facility. This protective gown has plenty of innovative features, including a seamless front design and an easy to don-and-doff design to reduce contamination risk and prevent hazardous liquids from getting on clothing or skin.
Liquid Barrier Gowns/Case
Seamless front and closed back; Easy to don and doff design
Enhanced liquid barrier protection- fabric tested for blood and blood-borne pathogen penetration, chemotherapy drug and hormone permeation to help protect people and processes from liquid splashes
Thumb loops to maintain glove and garment interface; survey, thumb loops are preferred among compounding pharmacists.
A solid frame made of anodised aluminium section forms the base for the unit. The bearings for the pulleys and gears are attached to the t-slots in the profile using clamping levers. This apparatus is used to demonstrate belt drives, wheel and disk drives, and gear trains. Basic terminology and relationships, e.g. the transmission ratio, direction of rotation reversal, reference circle and modulus, the function of intermediate gears, and so on can be clearly demonstrated. The size of the unit ensures that the experiment is clearly visible even for larger groups of students. These are easy to release and can be slid horizontally making a wide range of different set-ups possible. All experiments are carried out using manual power.
....The force of the water jet is adjusted via the flow rate. Experiments study the influence of flow velocity and amount of flow rate as well as of different deflection angles. The forces are calculated using the momentum equation and compared with the measurements. The jet forces generated by the water jet are measured on the weight-loaded scale. During deceleration, acceleration and deflection of a flowing fluid, there is a change of velocity that leads to a change in momentum. In jet forces are generated and studied with the aid of a water jet that acts on an interchangeable deflector. The experimental unit includes a transparent tank, a nozzle, four interchangeable deflectors with different deflection angles and a weight-loaded scale. According to the momentum equation these changes result in forces. In practice, the motive forces are used to convert kinetic energy into work done, for example in a Pelton turbine. A water jet exits a nozzle vertically upwards, hits the deflector and is deflected.
....The two sides are marked by colours: compression side - blue, turbine side - red. All parts can be easilymoved. The housing of the charger is cutin a way you can see compression wheel, turbine wheel and bearings. The housing of the charger is cut in a way you can see compression wheel, turbine wheel and bearings.
....The interior mechanical structure and function of car engine is clearly understood under its demonstration and operation to make students and learners raise their initial knowledge of the car power steering structure and its working principle. Transparent Power Steering Transparent Model educational equipment is professional teaching equipment for colleges, secondary vocational and technical schools, car driving training and vehicle repairing field.
....Load is measured by a high accuracy electric strain cell, eliminating the pistons weight and friction.
Multipurpose high flexibility testing machine.
C-shaped open frame for an easy and fast positioning of the specimen between the rollers.
The frame is closed by a hydraulic vertical rod, granting high rigidity.
Maximum vertical daylight between upper/lower rollers: 263 mm
Horizontal clearance (between uprights): 1040 mm
Maximum capacity: 320 KN
Ram travel: 110 mm
Graduated scales are foreseen to get easy rollers adjustment.
Simple action piston with counterweights to optimize frictions.
Possibility to easily place in the centre one upper roller for centre point loading.
Features:
Main Spindle And Pinon are Made out of Forged Steel.
Spindle Ram is made out of Steel.
Parts Properly Balanced
All Moving Parts Finished to Close Tolerance.
Parts finished on imported Grinding M/c.
Prior Assembling of Main Gear And Pulley.
The board is supplied complete with a set of stackable, plug-in cables of suitable lengths and colours and with a training manual.
Together with the board, that contains the power circuits complete with relevant piloting, it is possible to realize an open and closed loop control both of the position system (geared motor coupled to a potentiometer) and of the speed system (variable load generator dc motor with optical transducer associated to an F/V converter).
This board contains two independent systems, for the control of the position and of the speed respectively, error amplifier, each one complete with reference block, transducer and actuator.
Power supply: ± 15Vdc, 100mA
Chamber with wet (latent) and dry (sensitive) heat source as cooling load
Motorised flaps for recirculating and outer air operation
Air duct with fan, air cooler, humidifier, flaps, air heater and sensors
Process schematic with signal lamps
Air conditioning system ready for different automation solutions: 4 data cable connections to integrate the accessories
Model of an air conditioning system with outer air and recirculating operation
Air duct with transparent front
It is provided with an input summing point to which the reference variable (non inverting input) and the controlled variable (inverting input) are connected. Two position controller for discontinuous closed loop control systems. The controller is provided with two binary outputs at different voltages. By means of two led the binary state of the controller, whose hysteresis can be changed, is visualized.
....Trainer for control engineering experiments
Temperature measurement with thermocouples at multiple points
Generation of disturbance variables by ball valve with scale in water circuitv
Screw-in heater with dry-running protection and temperature limiter Air/water heat exchanger with fan
Process variables X and Y accessible as analogue signals via lab jacks
Thyristor power controller as actuator
Digital controller, configurable as switching or continuous controller
2-channel line recorder
Temperature control process, equipped with standard industrial components
Water circuit with pump, heater and 2 different lengths of process delay.
Syringe, two pieces: barrel with Luer nozzle and piston/plunger or three pieces: barrel with luer nozzle, stopper and piston/plunger.
Intended use: inject fluids into, or withdraw fluids from, the body
Blister packed.
Presentation Balance
....Dimension (L*W*H CM): φ24.5
....