A dedicated Hermetic Refrigeration Training Unit with a capillary flow control and a range of switch activated faults for student practice.
The unit includes: Fan cooled Hermetic Refrigeration Training Unit condensing unit with high starting torque compressor; Front mounted evaporator with suction accumulator; Liquid line dryer; Compound and Pressure gauges
Using the push button switches, five system faults can be introduced into the system: Faulty compressor valve; Choked capillary; Excess discharge pressure; Overcharged system; Undercharged system.
Vaccine storage capacity: 51 L
Volume category: <60L
Refrigerant: R600a, 45 grams
Energy consumption, stable running (kWh/24 hours): 1.63
Equipment operating voltage and frequency: 220-240 Volt, or 100-127 Volt and frequency 50Hz or 60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Volume category: <60L
Vaccine storage capacity: 37.5L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 90 grams
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Visual Refrigeration Training Unit operates on refrigerant. An electrical control box is mounted on the back panel and includes indicators/warning lamp, on/off contactor and overload, as well as residual current device for protection against earth leakage. Visual Refrigeration Training Unit comprise an air-cooled condensing unit with open type twin cylinder reciprocating compressor and a transparent plastic evaporator, clearly showing change of state of refrigerant from liquid to vapour phase. The unit also incorporates, Liquid/suction heat exchanger, Liquid line filter drier and sight glass, HP/LP switches, Compound and pressure gauges, Suction and discharge service valves fitted, Liquid line hand wheel valve fitted for easy manual pump down of system. The following refrigerant flow control options may be selected by the use of hand wheel valves: Automatic Expansion Valve; Thermostatic Expansion Valve, Internally equalised; Capillary with Separate Filter Drier.
....Vaccine storage capacity: 98.5 L
Volume category: >/= 60, <120L
Refrigerant: R600a, 45 grams
Energy consumption, stable running (kWh/24 hours): 1.23
Equipment operating voltage and frequency: 220-240 Volt, or 100-127 Volt and frequency 50Hz or 60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF- Grade A.
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Vaccine storage capacity: 100L
Volume category: >/= 60, <120L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 135 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Bench-Top Refrigerated Centrifuge
....The demonstrates the types of systems that are used in a lot of small applications in dangerous environments where systems using electrical power cannot be used or where there is no electrical power supply.
A Compressed Air Refrigeration Training Bench for studying refrigeration using compressed air. Using the whirling motion of a specially designed and shaped vortex distributor, the compressed air expands and is divided into a cold stream and a hot stream. This is an unusual method of producing cold air by the expansion of compressed air. The cold stream is utilised and the hot stream is exhausted into the environment.
The designed and manufactured to incorporate all current safety standards.
Experiments:
Thermodynamics of compressed air
Plotting the air transformation due to air expansion on a temperature-entropy diagram
Coefficient of performance (C.O.P) determination
Demonstration of producing hot and cold air through a system that has no moving parts
Determining the outlet temperature in relation to the feed pressure
Determining the useful refrigeration power
Detecting the operating curve of a vortex tube by varying the inlet pressure and the weight ratio between hot and cold air.
Advanced Refrigeration Training Unit is a multiple circuit unit, incorporating important secondary controls, is constructed entirely from standard commercial components and will give the student invaluable experience in fault diagnosis, system adjustment and replacement of faulty components.
The Advanced Refrigeration Training Unit is a fully operational, small scale cold room, which enables the student to relate all test results, system faults and adjustments directly to situations encountered in service and maintenance.
Volume category: Vaccine storage capacity: 52.5 L
Refrigerant: R600a, 60 grams
Energy consumption, stable running (kWh/24 hours): 0.63
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Combined Refrigerator and Water-Pack Freezer for storage of vaccines at +2 ?C to+8?C and freezing of water packs.
220-240 Volt 50Hz /60Hz, or 100-127 Volt 50Hz /60Hz, 1ph.
Vaccine storage capacity: 36 L
Volume category: <60L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 60 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Floor Refrigerated Centrifuge
....Vaccine storage capacity: 50 L
Volume category: <60L
Refrigerant: R134a, 315 grams
Energy consumption, stable running (kWh/24 hours): 0.77
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Equipment operating voltage and frequency.
220-240 Volt, 50Hz/60Hz or 100-127 Volt 50Hz/60Hz, 1ph.
Vaccine storage capacity: 52.5 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 70 grams
The hermetic condensing Reverse Cycle Refrigeration and Air Con Training Unit has a high starting torque motor with built-in winding protector, air-cooled condenser and liquid receiver. Reverse Cycle Refrigeration and Air Con Training Unit unit demonstrates both refrigeration and air conditioning principles as well as operation of two evaporators on one compressor by means of an evaporator pressure regulator. These comprise: Automatic expansion valve; internal equalised thermostatic expansion valve; External equalised thermostatic expansion valve. and Capillary tube with separate filter drier. A water cooled condenser is provided with an automatic condenser pressure regulator. Both the forced air evaporator and the static evaporator has a 3/8 O.D. copper tube coil block with aluminium fins. The Flow Controls may be selected by hand valves.
....Vaccine storage capacity: 240 L
Volume category: >/=120 L
Refrigerant: R600a, 60 grams
Energy consumption, stable running (kWh/24 hours): 0.85.
Equipment operating voltage and frequency: 220-240 Volt 50Hz /60Hz or 115 Volt /60Hz, 1ph.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
PQS Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Vaccine storage capacity: 88 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 70 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
An electrically driven ammonia-water Absorption Refrigeration Demonstrator with insulated chiller compartment. All major components of the refrigeration system: generator, absorber, condenser and reservoir are visible.
Digital wattmeter to give instantaneous indication of generator heater input and evaporator load.
Variable electrical load inside the freezer compartment
Variable generator heater.
Instrumentation:
Digital temperature indicator
Optional Computerised Data Acquisition System.
Vaccine storage capacity: 184 L
Volume category: >/=120L
Refrigerant: R600a, 70 grams
Energy consumption, stable running (kWh/24 hours): 0.803
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
PQS Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Equipment operating voltage and frequency.
220-240 Volt, 50Hz/60Hz or 100-127 Volt 50Hz/60Hz, 1ph.
Vaccine storage capacity: 132 L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 70 grams.