Supply unit for heat exchangers
Digital displays for 6 temperature and 2 flow rate sensors
Flow adjustable using valves
Water connections with quick-release couplings
Hot water circuit with tank, heater, temperature controller, pump and protection against lack of water
Temperature controller controls the temperature of hot water
Stirring machine connection with speed adjustment
Cold water circuit from laboratory mains or water chiller.
In this functional model of an original electromechanical power steering the componentsare exposed within the steering housing in order to demonstrate for example the operation of the double drive pinion. The system has a controlpanel with emergency stop switch, ignition switch, indicator light and OBDinterface. The power supply is provided by a vehicle battery. Optional errorcircuit 6 switches / 12 errors and associated test sockets in 4mm design. Because of the extremely high forces onall moving parts and rotating the open areas were fitted with transparentcovers for safety. More represent able functions are active reset in thedirectional stability as well as the controlled demand for power consumptionfor reduction in fuel consumption. Steering angle, powerconsumption and torque can be tested and measured using standard workshop diagnostic systems via the OBD interface. The communication between the controlunit for steering column electronics, the diagnostic interface (gateway) andthe Diagnostic Interface (OBD) is done via CAN Bus. Thus, the required effort withand without assistance can be represented visually. In order to increase the steering forcespartially, a resistance pressure box is mounted.
....Device With Central Screw can be foreseen on all models of concrete compression machines, except High Stability models. Recommended solution for machines equipped with big sized platens. Very practical to adjust the light between the compression platens of a machine, according to the height of the specimen to be tested.
....2 thermocouples type K: Temperature measurement at the top of the rod-type heater and at the inner surface of the ring heater.
Mounted with quick-action fasteners.
A non-sterile medium designed to be applied to a patient's unbroken skin surface to provide a coupling between an analytical device (e.g., ultrasound transducer, optical glucose monitoring system) and the patient, allowing for the emission and reception of signals (e.g., ultrasound, light) that pass through the skin during an examination. It may be used by a healthcare professional or layperson. After application, this device cannot be reused. It is in the form of a non-sticky, fluid-like gel that may also assists the operator's ability to move the analytical device smoothly over the skin to better analyse the site of interest.
....Inner packs dimension (L*W*H CM): φ1*11.2
....The circumference ratio demonstration consists of a circle wheel ( 100mm diameter ) and a scale below the tray.
The circle area demonstration consists of a 200mm diameter circle divided into 16 equal parts of the fan-shaped small pieces, and each one be divided into two small pieces .
Products are stainless steel products;
Four pieces for one set, including anatomical scissors, forceps, scalpel, anatomical needle each;
The tweezers are of moderate elasticity, close to the forceps arm, and the ends of the tweezers are closed, with no slits or micro slits;
Anatomical scissors tip, two blade cross anastomosis, flat;
There is no gap, the blade edge cracks, smooth straight needle.
Provides light-weight inherent barrier protection against hazardous dry particles and aerosols, and nonhazardous light liquid splash.
Lab coats provide the protection and durability you need so you can focus on the task at hand.
Can be used in a variety of applications including general maintenance/operations, asbestos and lead abatement, mold remediation, and environmental cleanups.
Excellent abrasion resistance due its unique, nonwoven material.
Measuring tube with scale and pressure sensor for manual and electronic fuel consumption measurement
Measured value displays for engine exhaust gas temperature
Measurement and display of air consumption, ambient temperature and fuel temperature
Test stand for mounting of prepared single-cylinder engines (two-stroke and four-stroke) with a maximum power output of 2,2kW
Engine started
Force transmission from engine to load unit via
V-belt drive
Vibration-dampened switch cabinet for display and control
Continuous adjustment of speed and torque using
3 supply tanks for different fuels
Stabilisation tank for intake air.
The Synchronous Machine is designed to operate as a motor or as an alternator. The rotor works as a square cage when starting and stopping. The three-stator windings are brought out to 4-mm separated terminals on the housing, so that they may be connected in wye or delta. The Synchronous Machine runs at constant speed independently of the load. The synchronous speed directly depends on the current frequency and on the number of motor poles. The trainer is also provided with supply terminals, a rheostat for control over the excitation current and a protective circuit breaker in the rotor circuit. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. The main characteristic of a Synchronous Machine is the possibility to change the power factor. Its stator is connected to an AC power supply and its rotor must be linked to a AC/DC rectifying unit. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Included in the Rotating Machines Trainer for 1/3 hp - 250 W. Requires a 120V 60Hz circuit.
....The guards are both on front, back and lateral side and are easily/quickly fixed to the machine with hooks. Fragment guards to Safety Directive, manufactured from highly resistant transparent polycarbonate material. Machines 3000kN and high stability 3000kN.
....A device designed to cut a syringe to prevent syringe reuse. It is typically located in the vicinity of where the syringes are used, e.g., on the ward, in anaesthesia induction rooms, in an intensive care unit (ICU), accident and emergency (A&E) departments, and laboratories. This is a reusable device. It typically includes a sharp metal cutting blade housed in a plastic container that receives the pieces of destroyed syringe.
....Inner packs dimension (L*W*H CM): 28.6*25*11.5
....Connector 20 pcs, ≥4 colors, C shaped, can be mutual connected.
....Products are stainless steel products;
Seven pieces for one set, including anatomical scissors,shearing scissors, tweezers, forceps, curved straight round bladed scalpel, straight bladed scalpel, the anatomy of a needle each ;
The tweezers are of moderate elasticity, close to the forceps arm, and the ends of the tweezers are closed, with no slits or micro slits;
Anatomical scissors tip, two blade cross anastomosis, flat;
There is no gap, the blade edge cracks, smooth straight needle.
Investigation of bar forces in statically over determinate trusses
Strain gauge to measure force on each bar
Measurement amplifier required
Surplus bar, longitudinally adjustable
Straight and inclined loading possible
Software to evaluate measurement data
Experimental set-up in frame.
Storage system to house the components.
Engine completely equipped with fuel line, throttle cable and exhaust gas temperature sensor
Air-cooled single-cylinder two-stroke petrol engine for installation in test stand
Fuel hose with self-sealing quick-release coupling
Force transmission to brake via pulley, gear transmission 2:1
Engine mounted on a base plate with vibration dampers.
The structure of the 2-zone Climatronic is based on the currentstate of the VW Golf. All parts are in original condition. This training system consists of the table model and the corresponding e-learning companion course. The practice course modules deepen and complement the theory modules ina unique way. The unit has a diagnostic port for connection todiagnostic tools. An error box lets you synchronize errors in the sensors andactuators. In addition, numerous test sockets are integrated. The individual control loops can be shown.
....The DEM is a three-phase asynchronous squirrel-cage motor mock-up that can be assembled and disassembled depending on needs.
This Dem Dissectable Machine is presented in a case containing the following items:
The motor housing with stator wiring, fitted with a terminal block
The fan
The left and right flanges
The squirrel-cage rotor
The screws with screwdriver kit.