Starters can be electric, pneumatic, orhydraulic. In the case of very large engines, the starter can even be anotherinternal-combustion engine. A starter(also self-starter, cranking motor, or starter motor) is a device used torotate (crank) an internal-combustion engine so as to initiate the enginesoperation under its own power.
....Demonstration of the following functions:
Turning of the rotor and the pinion-starter and controlsolenoid switches
Multi-disk clutch
Meshing, starting and disengaging
Moving contact and ratchet.
Engaging the starter pinion can be demonstrated.
The function of the planetary gearing is easy to identify.
Parts cut in this model:
Armature can be rotated and solenoid switch actuated.
Solenoid switch
Housing and windings.
Specifically, this learning system focuses on using a Safety PLC with Step 7 software to teach applicable reversing motor applications such as controlling the movement of a conveyor system that does not require a variable speed. Safety I/O With Reversing Starter Learning System teaches reversing motor starter configuration, programming, and operation in Safety PLC applications. Major topic areas within the curriculum are reversing motor starter operation, motor starter construction, disconnect module operation, starter configuration, and starter programming.
This learning system adds to the Programmable Controller Troubleshooting Learning System and the PLC Troubleshooting Learning System to expand offering of Safety PLC curriculum. The Safety I/O With Reversing Starter Learning System includes a reversing motor starter, discrete I/O modules, disconnect module, curriculum, instructors guide, and installation guide.
Features:
Teaches reversing motor starter configuration, programming, and operation in Safety PLC applications
Only source for reversing motor starter training on safety PLC applications
Focuses on using a Safety PLC with Step 7 software.
PLC Starter Kit Electronic Engineering Lab
....Subsonic Wind Tunnel Starter Set
....Steps operated starter for three phase induction motor with slip ring rotor.
....The interior mechanical structure and function of magnetic starter is clearly understood under its demonstration and operation. Transparent Magnetic Electric Starter Model educational equipment is professional teaching equipment for colleges, secondary vocational and technical schools, car driving training and vehicle repairing field.
....The Resistor Reduced Voltage Starter 60 HZ is a reduced-voltage three phase starter that uses one or many resistors in series to start a motor to obtain given torque measures or limited current values. Used in electrical engineering technology teaching when an AC stator-resistance starter is required, the starter unit is housed in a full-size totally enclosed portable modular unit. This permits the utilization of banana-type jumper leads between the single phase power supply and other components in the circuit. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. It is equipped with thermal protection facilities, a start-stop push-button station and two pilot lamps indicating respectively the supply, the run state of the motor driven and an adjustable time delay. Connections to the unit are made through 4 mm standard color-coded, five-way binding posts. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Requires a 120/208V 60Hz circuit.
Educational Advantages:
Used in electrical engineering technology teaching when an AC stator-resistance starter is required
Three phase unit
Indicates respectively the supply, the run state of the motor driven and adjustable time delay
The Part Winding Starter 60 HZ is a part winding starter used for motors of which two windings are connected in parallel for lower voltage requirements and two in series for higher voltage. This unit is used to teach principles of reduced voltage starting that applies power to only one set of windings, then to the other set as the motor comes up to speed. The starter is equipped with thermal protection, a start-stop push-button, two (2) pilot lamps indicating the starting steps of the motor and an adjustable time delay. This permits the utilization of banana-type patchcords. The specifications and diagram for the unit are silk-screened on the back of a clear-plastic front panel for ease of identification. The connections to the unit are made through 4 mm standard color-coded safety sockets. Power requirements: 120/208 V 50 Hz.
Educational Advantages:
Used to teach principles of reduced voltage starting that applies power to only one set of windings, then to the other set as the motor comes up to speed
Indicates respectively the supply, the run state of the motor driven and adjustable time delay.
It is equipped with thermal protection, a start-stop push-button station and two pilot lamps indicating respectively the supply, the run state of the motor driven and the time delay. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. The Synchronous Motor Starter 60 HZ is a starter that can be used to start any synchronous motor even at full load. Connections to the unit are made through 4 mm standard color-coded safety terminals. Used in electrical engineering technology teaching when an AC starter is required, the starter unit is housed in a half-size totally enclosed portable modular unit. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Requires a 120/208V 60Hz circuit. This permits the utilization of banana-type jumper leads between the single phase power supply and other components in the circuit.
Educational Advantages:
Used in electrical engineering technology teaching when an AC starter is required for applications with a synchronous motor
Three phase unit
Indicates respectively the supply, the run state of the motor driven and adjustable time delay.
The starter is equipped with thermal protection facilities, a start-stop push-button station and two pilot lamps indicating respectively the supply and the run state of the motor driven. It is housed in a half-size totally enclosed portable modular unit. The AC Magnetic Starter For 3 HP (2.2 KW) 60 HZ is a three phase magnetic starter for 3hp equipment that is used to teach AC motor control and start motors with higher power and control them at distance. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Connections to the unit are made through 4 mm standard color-coded, five-way binding posts. This permits the utilization of banana-type jumper leads between the power supply and other components in the circuit. Requires a 120/208V 60Hz circuit.
Educational Advantages:
Used in motor control technology teaching when an AC magnetic starter is required
Three phase unit for 3 hp
Indicates respectively the supply and the run state of the motor driven.
The unit is housed in a full-size totally enclosed portable modular unit. Connections to the unit are made through 4 mm standard color-coded safety terminals. This permits the utilization of banana-type jumper leads between the power supply and other components in the circuit. The Multi Speed Starter 1/3HP (250W) 60 HZ is used to start multi-speed motors with windings divided into parts for speed change. The trainer is equipped with thermal protection, low-stop-high push-button and two (2) pilot lamps to indicate respectively low and high speed. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Requires a 120/208V 60Hz circuit.
....The starter is equipped with thermal protection facilities, a start-stop push-button station and two pilot lamps indicating respectively the supply and the run state of the motor driven. The Delta Reduced Voltage Starter 60 HZ is used to start a motor having its six windings connected in wye for reducing voltage and in delta for increasing it. It is housed in a half-size totally enclosed portable modular unit. Connections to the unit are made through 4 mm standard color-coded, five-way binding posts. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Requires a 120/208V 60Hz circuit. This permits the utilization of banana-type jumper leads between the power supply and other components in the circuit. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification.
Educational Advantages:
Used to start a motor having its six windings connected in wye for reducing voltage and in delta for increasing it.
Indicates respectively the supply, the run state of the motor driven and adjustable time delay.
Three phase unit.
The starter is equipped with thermal protection facilities, a start-stop push-button station and two pilot lamps indicating respectively the supply and the run state of the motor driven. It is housed in a half-size totally enclosed portable modular unit. The Three Phase Magnetic Starter For 1/3 HP (250 W) - 60 HZ is a three phase magnetic starter for 1/3 hp (250 W) that is used to teach AC motor control and start motors with higher power and control them at distance. Connections to the unit are made through 4 mm standard color-coded, five-way binding posts. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Requires a 120/208V 60Hz circuit. This permits the utilization of banana-type jumper leads between the power supply and other components in the circuit. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification.
Educational Advantages:
Used in electrical engineering technology teaching when an AC magnetic starter is required
Three phase unit
Indicates respectively the supply and the run state of the motor driven.
The trainer is equipped with an Allen-Bradley SMC-3 smart motor controller, start-stop push-button and two pilot lamps that indicates respectively the supply and electronic controller state. The unit is housed in a full-size totally enclosed portable modular unit. The Soft Starter 60 HZ is used to start asynchronous motors with no current inrush to limit the starting current and provide with speed change. Connections to the unit are made through 4 mm standard color-coded safety terminals. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. This permits the utilization of banana-type jumper leads between the power supply and other components in the circuit. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. Requires a 120/208V 60Hz circuit.
Educational Advantages:
Used in electrical engineering technology teaching when soft motor starter is required.
Pilot lamps indicates respectively the Supply and Ovld/Fault soft starter.
The starter is equipped with thermal protection facilities, a start-stop push-button station and two pilot lamps indicating respectively the supply and the run state of the motor driven. This permits the utilization of banana-type jumper leads between the power supply and other components in the circuit. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. The Autotransformer Reduced Voltage Starter 50 HZ is an autotransformer reduced voltage starter for 1/3 hp (250 W) that is used to start squirrel cage motors that require limited current and reduced voltage at acceleration. It is housed in a half-size totally enclosed portable modular unit. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Connections to the unit are made through 4 mm standard color-coded, five-way binding posts. Requires a 220/380V 50Hz circuit.
Educational Advantages:
Used to start squirrel cage motors that require limited current and reduced voltage at acceleration
Indicates respectively the supply and the run state of the motor driven
Three phase unit
The startercan be slowed with a clutch equipped dial to a complete standstill. The resulting currents can be measured via the built-in ammeter. The teaching device starter test stand theprinciple of a starter can be explained in an impressive way. All necessarycomponents for functioning in the car are installed on the system. The test standis operated via a conventional 12 V car battery. From these values,the performance of the starter can be determined by calculation.
Components:
1 x Starter, original VW Polo 9N.
1 x Shunt 600 A.
1 x Start button.
1 x Flywheel with ring gear VW Polo 9N.
Clutch release bearing complete VW Polo 9N.
Ammeter to 600 A, after adjustable.
The starter is equipped with thermal protection facilities, a start-stop push-button station and two pilot lamps indicating respectively the supply and the run state of the motor driven. This permits the utilization of banana-type jumper leads between the power supply and other components in the circuit. Specifications and/or diagrams are silk-screened on the back of a clear-plastic front panel for ease of identification. It is housed in a half-size totally enclosed portable modular unit. The Autotransformer Reduced Voltage Starter 60 HZ is an autotransformer reduced voltage starter for 1/3 hp (250 W) that is used to start squirrel cage motors that require limited current and reduced voltage at acceleration. The trainer is protected by a either a diode or thermal-magnetic circuit breaker. Connections to the unit are made through 4 mm standard color-coded, five-way binding posts. Requires a 120/208V 60Hz circuit.
Educational Advantages:
Used to start squirrel cage motors that require limited current and reduced voltage at acceleration
Indicates respectively the supply, the run state of the motor driven and adjustable time delay
Three phase unit