Vaccine storage capacity: 36 L
Volume category: <60L
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 60 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
EV Battery Lift (Capacity 1 Ton)
....Fungal Growth Incubator (5oC to 80oC)
....Vaccine storage capacity: 52.5 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 70 grams
A hand-held, electrically-powered instrument designed to estimate the temperature of a site on the skin (e.g., axilla, forehead) by measurement of body infrared emissions at this particular point. This device may be used in the home. This is a reusable device. It provides a method to determine temperature patterns or variations on the surface of the skin (e.g., due to differences in perfusion).
....Laboratory Water Bath
....Vaccine storage capacity: 88 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 70 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
An infant incubator provides a closed, controlled environment that warms an infant by circulating heated air over the skin. Incubators feature better temperature control than radiant warmers (overhead heating units), which can overheat or underheat the infant. However, an infant in an incubator is less accessible to the caregiver. The heat is then absorbed into the body by tissue conduction and blood convection. Ideally, both the skin and core temperatures should be maintained with only minor variations.
....New Energy (Battery Energy Vehicle) Whole System
....Vaccine storage capacity: 132 L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 70 grams.
Our offered bath is thoroughly checked on various parameters to ensure zero-defect. This bath is widely used in national laboratories and pharmaceutical industries. This bath is designed and developed under the strict supervision of our experienced professionals in accordance with the international quality standards.
Features:
Ideal for controlling the temperature accuracy
Durable glass bath for optimum heat preservation
Desktop based all-in-one design for easy operations and portability
Intelligent signal sampling for accurate data measuring and parameter reading
Accurate viscometer for improving experimental efficiency
Easy cleaning and drying of viscometer tubes.
High precision digital display
Electric stirrer for ensuring uniform temperature of bath.
Vaccine storage capacity:59L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 45 grams
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
EV Traction Battery Pack Loading and Testing Training Platform
....Vaccine storage capacity: 46.5 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 38 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Vaccine storage capacity: 99 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 76 grams
It is used in school biological laboratory, plant germination, seedling raising, tissue culture, microorganism culture, rearing of insects and small animals, BOD determination of water body analysis, etc..
Light incubator is a high precision constant temperature equipment with illumination function.
Programmable preset temperature, light intensity, and can set 99 control periods, each set of time range of 1-99 hours, you can simulate the day and night temperature, light changes.
The product adopts microcomputer intelligent control.
Heating power: 1000W;
Light power: 48W;
The illumination ≥2500Lx;
Temperature control range: full illumination 10?50? / no light 5?50?;
Temperature accuracy: ±1?;
Temperature uniformity: 2?;
Range of illumination: 0 - 12000Lx;
Compressor power: 75W.
New Energy (Battery Energy Vehicle) Whole System Electronic Engineering Lab
....Electronic conductivity meter with automatic temperature compensation
Circuit for connection with a vacuum pump including check valve
Electronic rpm indicator for the stirrer
Distillation column packed with stainless steel mesh
Overhead condenser
Reactor with a capacity of 3 litres and 1.0 kW electric heater
Stirrer for the reactor, 0 to 400 rpm, with a mechanical seal that is lubricated with silicone oil
Tanks for adding reagents with a capacity of 1 litre
Tanks for collection of distillate with 2 litres capacity
2 electronic temperature indicators
2 thermocouples with pt100 probes protected by stainless steel shield sleeves
Vacuum gauge range 1 to 0 bar .
Emergency stop button
Electrical control panel in main cabinet
Pipe work and valves manufactured from stainless steel.
Vaccine storage capacity: 36 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 40 grams, R600a, 30 grams, R290, 10 grams.