Performance: Power supply voltage: single phase 220V + 10% (50Hz)?Power rating: 300W?Operating temperature range: 20?60 ??Temperature fluctuation: no more than ±1?.
Function: for vaccine culture.
ELISA Plate Incubator
....Vaccine storage capacity: 220 L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 65 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
This 4-Pack of AA batteries is for use with various colorimeters, turbidimeters and other instruments.
....EV Traction Battery Pack Loading and Testing Training Platform Electronic Engineering Lab
....Vaccine storage capacity: 50 L
Volume category: <60L
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 150 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Vaccine storage capacity: 100L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 65 grams.
Incubator Shaker Biological Shaker
....Vaccine storage capacity:200L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 65 grams.
Incubators for Microbiology
....Vaccine storage capacity: 80.5 L
Volume category: >/=60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 60 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 61.25 L
Volume category: >/=60, <120 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 50 grams, R600a, 30 grams, R290, 10 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 48 L
Volume category: <60 L
Ambient operating temperature: Min. +5°C, Max. +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R290, Refrigerator system: 55g/Freezer system: 45g.
Vaccine storage capacity: 120 L
Volume category: >/=120L
Autonomy time: Appliance’s autonomy at +43 ?C ambient: 82 hours 5 minutes
Refrigerant: R600a, 57 grams / Freezer: 47 grams
Operating temperature: +5 °C to +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Vaccine storage capacity: 110 L
Volume category: >/=60, <120 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 75 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 58 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF: Grade A
Refrigerant: R290a, 35 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Gros volume-Freezer: 34.3 L
Volume category: <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Max rated ambient temperature: +43°C
Refrigerant: R600a, 30 grams, R290a, 10 grams
PQS prequalified Solar direct drive water packs freezer with no battery for freezing of water packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Vaccine storage capacity: 55.5 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 50 grams.