Vaccine storage capacity:59L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 45 grams
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
The mobile workstation is equipped with silkscreened labels for component identification; storage/inventory of clamp meter; digital meter; and storage for consumables, including wire and conduit, directly at the workstation. The Solar Photovoltaic Installation Learning System includes a mobile workstation with solar photovoltaic components, PC-based interactive, multimedia student curriculum; installation manual, and teachers guide.
Solar Photovoltaic Installation Learning System teaches students the installation and commissioning of grid interactive and stand-alone photovoltaic systems for commercial and residential applications. The demand for qualified Solar Technicians is rising, as more consumers and businesses apply solar energy in their communities. Students will learn how to develop and implement a site layout; select and install wiring; calculate PV circuit voltage and currents; and install real world components in PV systems, just as they would do on the job.
Features:
Interactive Multimedia Curriculum
Efficient, Effective, and Safe Training
Installation Skills Practice
Two Real-World installation Processes
Additional Requirements:
Solar PV Hand Tool Package
Solar PV Array Station
Consumables Package.
Vaccine storage capacity: 46.5 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 38 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
The module includes the components as used in the Prius scaled down for quick and easy instruction. Included is a 12-20 Volt Solar Panel, Solar ECU, Blower, Relay High Output Blower Fan and Ventilation Control Switch. Automotive Solar Ventilation Trainer /program is designed to demonstrate the basic operation of the optional Solar HVAC assist offered. The air inlet/outlet Servo function is simulated with colored lights to show timed operation while the actual air flow comes through the live dash vent.
....Vaccine storage capacity: 99 L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 76 grams
Vaccine storage capacity: 36 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 40 grams, R600a, 30 grams, R290, 10 grams.
Complete with connecting cables, experiment manual, interface to PC and software for data acquisition and display. Solar Wind Fuel Cells Energy Trainer has been designed for the study of renewable energies: solar energy, wind energy and hydrogen fuel cell systems.
Training Objectives:
Determining characteristic curve of solar panel
Hydrogen/oxygen or hydrogen/air operation
Assembling a fuel cell
Determining electrolyser efficiency
Learning about Faradays laws
Determining characteristic curves of fuel cell
Producing and storing hydrogen
Determining decomposition voltage of water
Building a model hydrogen car
Using methanol to generate electricity
Determining characteristic curve of electrolyser
Determining fuel cell efficiency
Voltage and current in a series connection of solar panels
Voltage and current in a parallel connection of solar panels
Determining characteristic curves of DMFC
Influence of the surface of a solar module on voltage and current intensity of a solar module.
Vaccine storage capacity: 220 L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 65 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Vaccine storage capacity: 50 L
Volume category: <60L
Operating temperature: Min and Max rated ambient temperature: +10°C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 150 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Vaccine storage capacity: 100L
Volume category: >/= 60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 65 grams.
Solar Motion Instrument
....Vaccine storage capacity:200L
Volume category: >120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5°C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 65 grams.
Vaccine storage capacity: 80.5 L
Volume category: >/=60, <120L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 60 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
Vaccine storage capacity: 61.25 L
Volume category: >/=60, <120 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Refrigerant: R600a, 50 grams, R600a, 30 grams, R290, 10 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A.
The light intensity can be manually adjusted through a potentiometer or automatically controlled to allow performing experiments with different light intensities, therefore simulating the light conditions from dawn to twilight. Lamps For Photovoltaic Solar Trainers is used to provide suitable lighting to the photovoltaic solar module.
The Lamps For Photovoltaic Solar Trainers includes the following main components:
Magnetothermal switch, differential 10A
Potentiometer, 10k
4 off halogen lamps, 300 W each
Dimmer for controlling the light intensity.
Vaccine storage capacity: 48 L
Volume category: <60 L
Ambient operating temperature: Min. +5°C, Max. +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R290, Refrigerator system: 55g/Freezer system: 45g.
Complete with connecting cables and experiment manual. Photovoltaic Solar Energy Trainer is mounted on a mobile structure that allows it to be moved to the venue for practical sessions and allowing the photovoltaic panel to receive solar radiation.
Training Objectives:
The photovoltaic panel, which can be inclined through a range of 0 to 90, and the calibrated cell used to measure solar irradiation, are on one side, and all of the components of a basic photovoltaic facility used to provide 12 V of direct current and 230 V of alternating current are on the other side.
Identification of all components of the trainer and how they are associated with its operation
Measurement of the voltage and power parameters of the photovoltaic panel
Programming the load regulator
Analysis of the installation of the trainer
Measurement of solar irradiation
Alternating current supply
Direct current supply.
Vaccine storage capacity: 120 L
Volume category: >/=120L
Autonomy time: Appliance’s autonomy at +43 ?C ambient: 82 hours 5 minutes
Refrigerant: R600a, 57 grams / Freezer: 47 grams
Operating temperature: +5 °C to +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Solar Training Set (Power Case)
....