Composed of stainless steel outer barrel, plastic float, blowing pipe, nozzle, exhaust port.
Capacity: 5.5L.
Nitrile Exam Gloves are reliable, easy-to-wear gloves that are more economical than standard nitrile gloves, and are suited for a wide variety of tasks.
The nitrile gloves deliver enhanced dexterity, thanks to textured fingertips, and are not made with natural rubber latex.
Nitrile Gloves can be an important piece for creating a more efficient, responsible workplace.
The gloves are static dissipative in use. They come in an innovative dispenser box, which incorporates two separate openings.
The first, smaller opening is used when the box is full and helps control dispensing to lessen waste from dropped gloves or multiple dispensing.
When the box is half empty, the second, larger opening allows easier access to the gloves. They have an 1.5 for pinholes and can even be recycled with the Kimberly-Clark Professional RightCycle program, the first large-scale recycling program for nonhazardous lab and cleanroom waste.
Exceptional value: 250% more gloves per case (versus standard nitrile gloves)
Waste less with the one-at-a-time dispenser box; Element Nitrile Gloves are recyclable through the Right Cycle program.
Not made with natural rubber latex, are powder -free and feature beaded cuffs
Superior quality.
Computer Controlled Gas Laws Unit (Boyle and Gay-Lussac Laws)
....Semi Circular Glass Block
....The Computerized Refrigeration Study Unit With Mass Energy Balance is an extremely easy-to-use and functional unit able to permit the study of a compression frigorific cycle and the evaluation of the cycle efficiency and the energy balance at the evaporator and at the condenser. A front panel with mimic diagram and instrumentation allows to keep the most significant thermodynamic quantities under control, so facilitating the students understanding and the teachers task. The unit is supplied with manuals which describe the components, the installation and utilization procedures as well as many exercises with experimental results. Moreover, the transducers and the dedicated software allows the data acquisition of the main thermodynamic quantities and to obtain or as a table or as a graph, the acquired values and the thermodynamic calculated quantities. The unit allow the study of the main thermodynamics quantities as a function of the thermal load at the evaporator and the calculation of the power required at the compressor shaft.
....Again these all take place with the repeatability advantages that electronic and software control brings. The addition of the process vessel allows more complex process control problems to be addressed, including remote set point demonstrations.
Single loops in combination:
Temperature control of reactor contents by varying heating fluid flow rate
Temperature control of heating fluid by varying heater power
Conductivity control of reactor contents by varying flow rate of one component.
Compass for blackboard, 40cm long, hard white plastic, with sturdy metal butterfly screw for adjusting tightness by hand. Interchangeable suction foot and compass point in soft plastic. Holder with convenient mechanism that is adjustable for round and square chalk.
....Suitable for professional clinical use, all patient categories neonate, infant, adult
Robust shock resistant design allow use in demanding environments
Ultra-compact pulse oximeter integrated into finger/toe clip
Measuring ranges:
SpO2 resolution: 1% or less
SpO2 accuracy within: +/-3%
SpO2 detection within the range of: 70 to 99%
Pulse rate accuracy: within: +/-3%
Pulse rate detection: 30 to 240 bpm
Pulse rate resolution: 1 bpm)
Enclosure protection IPX2 or better
Suitable for cleaning and disinfection with hospital-grade cleaning products.
Display shows SpO2, pulse rate, signal strength, sensor error or disconnect and low battery.
Power requirements two 1.5V AAA batteries
Accommodates finger/toe thicknesses 8 to 25mm directly or through the use of a separate sensor which can be connected to the device.
Spot-check of arterial blood oxygen saturation (SpO2) and heart rate(HR)
Batteries must allow at least 2500 spot-checks, calculated at 30 seconds per spot-check, or at least 21 hours of operation.
The unit is equipped with an automatic power off feature.
For grasping organs, soft or heavy tissue.
Material: Martensitic steel (quenched, magnetic steel).
Martensitic steel composition: 0.15-0.20% carbon, 12-13% chromium.
Precise adjustment of the teeth.
Hard ratchet, lockable.
Pressure force instrument: tissue grasping forceps, springy.
4 x 5 teeth.
Length: 15 cm.
Reusable.
Industrial Machines Control Assembly Training
....Large Base For Rod With Possibility To Support 2 Rods At The Same Time
....This instructional kit provides the necessary material for students to learn systematically how a hub and a shaft can be joined together in a professional way using feather keys. The material is clearly laid out on a plastic tray. The well-structured instructional material outlines all the necessary technical information and provides a step-by-step guide through the exercises. We recommend that the exercises are carried out in a workshop, as all preparations such as filing, drilling, countersinking and tapping must be carried out in a correct and proper manner by the student.
....The Refrigeration Study Unit With Mass Energy Balance is an extremely easy-to-use and functional unit able to permit the study of a compression frigorific cycle and the evaluation of the cycle efficiency and the energy balance at the evaporator and at the condenser. A front panel with mimic diagram and instrumentation allows to keep the most significant thermodynamic quantities under control so facilitating the students understanding and the teachers task. The unit is supplied with manuals which describe the components the installation and utilization procedures as well as many exercises with experimental results. The unit allow the study of the main thermodynamics quantities as a function of the thermal load at the evaporator and the calculation of the power required at the compressor shaft.
....The gear wheels and the synchronisations are easy torecognise
A six-speed manual transmission of the latest generation.
The shafts can be rotated and the box can be shifted intoall gears
The transmission is installed in the new Mercedes-Benz C-Class
Temperature, level, flow and conductivity control loops can be implemented
Manual control, single feedback loops, through to sophisticated cascade loops and distributed supervisory control of the whole process by a remotely located computer can be demonstrated
The effect of dead time and heat recycle can be demonstrated
A bench mounted process plant trainer with multiple streams both interacting and noninteracting. The process plant incorporates a miniature three-stage plate heat exchanger heated from a hot water circulator, two independent feed tanks, a holding tube with product divert valve and two variable-speed peristaltic pumps
An electrical console provides measurement and control of the process plant and enables a variety of control techniques including manual operation, on/off control, control from an external signal and control from a PC or PLC
The equipment incorporates electrical fault simulation and control, data logging software, and a USB computer interface.
Features:
Multiple inputs, multiple sensors, multiple control strategies
Operational sequencing, including startup and shutdown
Recycle implications on process control
Effects of dead time
Manual control, single feedback loops, through to sophisticated cascade loops
Temperature, level, flow and conductivity control loops can be implemented.
Computer interface unit and software are included. The Virtual Work Computer Assist set has the same accessories as except Moment Supports are replaced by Moment Load Cells, and Vertical Force Support is replaced by Vertical Force Load Cell.
....The deflection of a spring depends on the load applied to it, an observation enshrined in Hooke's Law Applications of springs are found in spring balances which indicate loads by measuring spring deflections and in car suspensions where they absorb energy caused by wheel vertical movement due to potholes and bumps. Compression of Springs Apparatus are used in engineering to store energy or to provide restoring forces. Both compression and tension springs may be encountered.
Experimental Capabilitis:
Using the optionally available compressive spring set the dependence of spring stiffness on the wire diameter, spring diameter, length, number of turns and material can be observed and calculated
To determine spring stiffness using measured experimental results and formulae provided
To test the relationship between the load applied and the change in compressive length of a spring
Load versus compression graphs
Action of springs.
Material: Martensitic steel (quenched, magnetic steel).
Martensitic steel composition: 0.15-0.20% carbon; 12-13% chromium.
To grip soft and delicate tissues (lungs, intestines, stomach).
Pronounced but atraumatic ridges of the grippers.
Ridged grippers with aperture (triangular).
Pressure force instrument: gripping forceps, springy
Soft ratchet, lockable.
Flexible arms.
Length: 23 cm.
Jaw: approx. 27 mm.
Reusable.
Combine outstanding particulate protection with comfort
Feature patent-pending, which promotes freedom of movement
Constructed of Microforce Barrier SMS abrasion-resistant fabric
Patented Reflex design provides 12% more chest room and 6% longer body length
Coveralls provide breathable splash and particle protection. Ideal for use in pharmaceutical research, fine particle contamination, aerospace and maintenance/general manufacturing applications.
All coveralls have zipper front with 1 in. (2.5cm) flap, elastic back and front
White.