Psychiatric Bed Mattress
....Once sterile, the UHT system is then placed in process mode and the into vessel fill mode. Sterilised product then fills the vessel. The UHT/filling system and the Sterile Vessel are first sterilised in separate processes. Time and temperature for the sterilisation process is set from the touchscreen.
The Sterile Vessel is controlled via a touchscreen mounted on the unit with modes for vessel filling, vessel emptying (bottling), sterilisation and cleaning. Vessel volumes range from 10 to 30 litres.
Features:
Automated process operations
Product agitation using a sterile gas supply
10-30-litre vessel volume
Touchscreen display
Steam sterilisable by external or integral supply
Variable sterilisation protocol control from touchscreen display
Continuous level sensing
Clean-in-place capability
Can be integrated into Armfield or other UHT/filling systems.
To reduce environmental pollution it is necessary to improve the efficiency of the engine for what concerns the exhaust gases. The combustion of the fuel inside the cylinders of an engine is, usually, incomplete. The more it is incomplete, the bigger is the Emission of noxious components which can be found in the exhaust gases from the engine.
This simulator takes into consideration all the relevant subjects and in particular:
Preparation and control of the fuel and operating conditions
Adaptation to the operating conditions
Composition and control of the exhaust gases in the Otto cycle based engines
Recirculation of the exhaust gases
Anti vaporation of the fuel
Combustion products
Analysis of the exhaust gases in the Otto cycle based engines: test cycles
Lambda regulation
Catalytic thermal post combustion.
The hermetically sealed refrigerant compressor incorporates a brushless three phase DC electric motor that is driven by a variable speed controller. Compressor speed and power supplied is displayed on the PC.
The condenser and evaporator are brazed plate heat exchanger and utilize a large common reservoir of water to minimize changes in water temperature during operation. The refrigerant exiting the compressor passes through a condenser, receiver, filter, variable area flow meter, expansion valve and evaporator before retuning to the inlet side of the compressor.
Electronic pressure sensor
Solenoid valve to generate disturbance variables
Pressure control in a tank
Software-based controlled system simulation
Experimental unit for control engineering experiments
Process schematic on front panel
Speed controlled diaphragm gas pump.
The unit provides common instrumentation for all of the options. Specialized instruments are included as required with the modules. The main unit consists of an instrumentation and control console that supplies a variable flow of compressed air to the range of optional modules.
....Cup drawing Display error 0.01mm
Max force 300kN
Clamp force 300kN
Clamping force relative error 2%
Test force range 2%100%
Test force display error 1%
Displacement resolution 0.002mm
Stamping stroke 120mm
Clamp stroke 40mm
Stamping speed 130mm/min
Plate maximum width 200mm
power 3.7kW/AC380V/50Hz
frame 930mmx1260mmx1400mm
weight About 1800kg
Features:
Dynamic display of load, displacement, time and real-time testing curve on the screen.
Constant loading speed test supported.
Capable of holding on maximum load or displacement.
Support for multi-language user-interface extendibility.
Closed loop control of channels such as load, displacement, etc. Smooth switching in between.
Features:
Automatically retrieves test data and inspects the stress relaxation performance of the specimen. (e.g. stress relaxation rate, relaxed stress, relaxation rate, etc.)
Splitting the sampling stage into four sub-stages and applies different sampling cycles in consideration of the logarithm characteristic of time, improving the reliability of data greatly.
Support for 100-hour tests. Test time can be assigned at will. E.g. 24-hour test.
Algorithm to predict specimen stress relaxation performance after 1000 hours (or any specified value in hours), with the option of single or double logarithm.
Comparing a framed structure with a column-based structure, the framed structure has better stiffness that is over 2.5 times greater than the column-based structure.
Closed test space design reduces the temperature shift resulted from the air flow at the air-conditioner vent, improves the temperature uniformity and stability in the test space.
Capable of predicting with standard specimen data or real-time collected data (Suggested). Integrated with an extensive specimen library to improve the precision and reliability of testing results.
Real-time drawing of curves of remaining load with time, or temperature with time.
Closed loop control of channels such as load, displacement, deformation, etc. Smooth switching in between.
As many as 20 layers of sensor linear compensation, elevates the precision of the instruments to the next level.
Pre-installed with reaction frame, provides more convenience for the load transducer to calibrate.
The Water Pumps Assembly Testing Bench teaching unit is a modular group designed to perform complete functional tests on a series of 4 water pumps. Each pump is taken into consideration individually and with it the following characteristic data can be obtained:
Suction pressure
Power consumption
Delivery pressure
Speed
Flow rate
The steam bench includes a 2- pen chart recorder to provide a continuous recording of the process variables, namely temperature and pressure and gives students the opportunity to become familiar with the presentation of such data on a typical process recorder used in industry. Pressure and Temperature Steam Bench consists of a sturdy framework and panels of all steel construction, fitted with a student work surface, interconnecting back panel and adjustable feet.
Experimental Capability:
To compare the experimental observations with published data such as in steam tables.
To investigate the relationship between the temperature and pressure of saturated steam.
Process Control Trainers Vocational Training Equipment Didactic
....Class III cabinets are designed for microbiological work demanding extremely high levels containment and are therefore often used for work involving some of the deadliest biohazards, bacteria, viruses and microorganisms.
Intended use: Airstream Class III, Biological Safety Cabinet, 4ft/1.2m is offer the highest level of product, operator and environmental protection from infectious and bio-hazardous aerosols.
Vital signs monitors are used to measure basic physiologic parameters and track the status of low-acuity patients (patients found in medical-surgical areas, emergency departments, and ambulatory care centres) so that clinicians can be informed of changes in a patient's condition.
Patient vital signs monitor, 6 parameters, suitable for adults, paediatric/infants and newborn patients.
Steam sterilization kills microbes effectively and is often viewed as the gold standard of healthcare sterilization methods. For sterilization of full solid, porous, hollow A and B, plastics, rubber, unwrapped, bagged, single or double wrapped. Not designed for sterilization of liquids, food stuffs or waste. Steam sterilizers use pressurized steam to generate moist heat to eliminate viable microbes from non-heat-sensitive medical devices, including heat-tolerant products used for surgical and general patient care.
The sterilizer is suitable for wrapped, unwrapped, solid and hollow items as well as porous loads such as drapes and gowns.
The unit fitted with a front-loading door.
The unit is provided with a minimum of three (3) internal shelves.
The unit has a standard program at 2.2 bar at a temperature of 134°C.
The unit has a standard program between 1.0 and 1.1 bar with a temperature between 118 – 121°C.
The internal chamber made from stainless steel 316Litre.
The internal chamber has a volume of 40 Litres or more.
Vacuum relief line should be filtered with ≤0.3 µm pore size to allow sterile air into chamber.
The unit is fitted with a safety lock on the front door, preventing the door to be opened when the unit is under pressure.
The unit provided with an internal water tank with a capacity of 4.2 litre or more.
The unit is designed and constructed in such a manner that it is able to withstand frequent disinfection with hospital-grade products.
The unit is able to function on a single-phased power grid.
The unit equipped with a steam generator.
The unit is designed in such a way that outer surfaces remain at safe temperatures when the unit is in operation.
Power requirements: 240 Volts - 50/60 Hz (A 110 Volt unit is not available).
DISPLAY FEATURES
The unit is fitted with a front panel providing information on the unit.
The display indicates:
The current internal temperature.
The current internal pressure.
The time until the programme is finished.
Any alerts or alarms.
The ongoing cycle.
ALARM AND SAFETY FEATURES
Alarms are audible as well as visual.
Alarms are available for/when:
Low water.
Door not closed.
Temperatures are about to reach limits of the equipment.
Pressures are about to reaching limits of the equipment.
Exceeding high temperature limit.
Failed cycles.
Power failure
The unit is provided with an over-pressure safety valve and an over-temperature safety system.
A notification that the end of sterilization cycle has been reached.
Drop Forged Carbon Steel
Hardened & Tempered
Fitted with Chemically Treated & Seasoned Wood Handle.
Gas Chromatography mass Spectroscopy Triple Quadrapole GC-MS and MS
....Rockwell Hardness Tester
....Pneumatics Trainer Board and Accessories
....Staff Gauges Plates + Accessories
....