Rectangular mosquito net, polyester 100 DENIER, treated with WHO PQ qualified insecticide, colour white/blue/green, dimensions 180 x 160 x 150 cm (length x width x height) +/-5%.
....Foster Walk-in type cold room, mono block, 10m3 for storage of vaccines at national and sub-national levels.
Internal dimensions: L=2100 x W=2100 x H=2100 mm
External dimensions: L=2300 x W=2300 x H=2300 mm
Register, A4, squared, 80 pages, pack of 10
....Steam sterilization kills microbes effectively and is often viewed as the gold standard of healthcare sterilization methods. For sterilization of full solid, porous, hollow A and B, plastics, rubber, unwrapped, bagged, single or double wrapped. Not designed for sterilization of liquids, food stuffs or waste. Steam sterilizers use pressurized steam to generate moist heat to eliminate viable microbes from non-heat-sensitive medical devices, including heat-tolerant products used for surgical and general patient care.
....Urethral catheter with balloon: Foley catheter 2-way with nelaton tip.
Central channel for urinary drainage, straight rounded distal end with lateral eyes, proximal end with cup connector allowing catheter to be connected to urine bag.
Diameter expressed in Charriere, French gauge.
Length expressed in cm.
Balloon capacity expressed in ml.
Side channel for inflating balloon, ending by a non-return valve with Luer tip connector.
Colour code / external diameter visible on connector.
Once sterile, the UHT system is then placed in process mode and the into vessel fill mode. Sterilised product then fills the vessel. The UHT/filling system and the Sterile Vessel are first sterilised in separate processes. Time and temperature for the sterilisation process is set from the touchscreen.
The Sterile Vessel is controlled via a touchscreen mounted on the unit with modes for vessel filling, vessel emptying (bottling), sterilisation and cleaning. Vessel volumes range from 10 to 30 litres.
Features:
Automated process operations
Product agitation using a sterile gas supply
10-30-litre vessel volume
Touchscreen display
Steam sterilisable by external or integral supply
Variable sterilisation protocol control from touchscreen display
Continuous level sensing
Clean-in-place capability
Can be integrated into Armfield or other UHT/filling systems.
Rectangular mosquito net, polyester 100 DENIER, treated with WHO PQ qualified insecticide, colour white/blue/green, dimensions 190 x 180 x 150 cm (length x width x height) +/-5%.
....Foster Walk-in type cold room, mono block, 30m3 for storage of vaccines at national and sub-national levels.
Internal dimensions: L=3690 x W=3690 x H=2100 mm
External dimensions: L=3890 x W=3890 x H=2300 mm
The product is not permeated by water in the following situations: prolonged water exposure, heavy top-down watering, forceful water pressure applications, or submersion. Shell fabrics: 100% polyester, 1200 x 600 denier, tightly woven and spun to resist puncturing, triple PVC/rubber blend coating material.
Lateral fixations and Length adjuster
Carrying handle
Cyan piping tape for seams
Shoulder strap
Zips: Zinc alloy
Capacity of Bag: Suitable to carrying a weight of 15kg.
Base reinforcement: Supplied with a loose bottom plate of 1 mm PVC board, dimensions 600 x 230mm (tolerance of +/- 50mm).
Steam sterilization kills microbes effectively and is often viewed as the gold standard of healthcare sterilization methods. For sterilization of full solid, porous, hollow A and B, plastics, rubber, unwrapped, bagged, single or double wrapped. Not designed for sterilization of liquids, food stuffs or waste. Steam sterilizers use pressurized steam to generate moist heat to eliminate viable microbes from non-heat-sensitive medical devices, including heat-tolerant products used for surgical and general patient care.
The sterilizer is suitable for wrapped, unwrapped, solid and hollow items as well as porous loads such as drapes and gowns.
The unit fitted with a front-loading door.
The unit is provided with a minimum of three (3) internal shelves.
The unit has a standard program at 2.2 bar at a temperature of 134°C.
The unit has a standard program between 1.0 and 1.1 bar with a temperature between 118 – 121°C.
The internal chamber made from stainless steel 316Litre.
The internal chamber has a volume of 40 Litres or more.
Vacuum relief line should be filtered with ≤0.3 µm pore size to allow sterile air into chamber.
The unit is fitted with a safety lock on the front door, preventing the door to be opened when the unit is under pressure.
The unit provided with an internal water tank with a capacity of 4.2 litre or more.
The unit is designed and constructed in such a manner that it is able to withstand frequent disinfection with hospital-grade products.
The unit is able to function on a single-phased power grid.
The unit equipped with a steam generator.
The unit is designed in such a way that outer surfaces remain at safe temperatures when the unit is in operation.
Power requirements: 240 Volts - 50/60 Hz (A 110 Volt unit is not available).
DISPLAY FEATURES
The unit is fitted with a front panel providing information on the unit.
The display indicates:
The current internal temperature.
The current internal pressure.
The time until the programme is finished.
Any alerts or alarms.
The ongoing cycle.
ALARM AND SAFETY FEATURES
Alarms are audible as well as visual.
Alarms are available for/when:
Low water.
Door not closed.
Temperatures are about to reach limits of the equipment.
Pressures are about to reaching limits of the equipment.
Exceeding high temperature limit.
Failed cycles.
Power failure
The unit is provided with an over-pressure safety valve and an over-temperature safety system.
A notification that the end of sterilization cycle has been reached.
Material: Polyethylene/vinyl acetate (EVA) - Polyvinyl chloride (PVC).
Sterile, single patient use.
Oro-pharyngeal airway, Guedel type.
Flange colour coded and/or marked with corresponding size number.
Size: Airway Guedel, size 4, approximately 90mm.
Initial sterilisation method:
Ethylene oxide gas or gamma radiation
Semi-rigid, transparent.
Proximal (or buccal) end straight and reinforced.
Rockwell Hardness Tester
....A simple deadweight tester with weights and a bourdon tube pressure gauge with a clear front allowing the mechanism to be viewed. The unit has an optional pressure transducer available allowing the concept of electronic representation of pressure to be investigated. Unique design allows standard Newton weights to be used; hence reinforcing the student understanding of pressure being Force / Unit Area.
....In a tandem master cylinder for a vehicle hydraulic brake system havinga push-rod piston designed as stepped piston and anintermediate piston designed as stepped piston both pistons being aligned in a stepped bore of the cylinder housing forthe purpose of obtaining a particularly short and compact design.
....Rectangular mosquito net, polyester 100 DENIER, treated with WHO PQ qualified insecticide, colour white/blue/green, dimensions 190 x 180 x 180 cm (length x width x height) +/-5%.
....Foster Walk-in type cold room, mono block, 40m3 for storage of vaccines at national and sub-national levels.
Internal dimensions: L=4260 x W=4260 x H=2100 mm
External dimensions: L=4460 x W=4460 x H=2300 mm
Cylindrical container used to sterilise dressing materials (gauze compress or cotton etc.) in a steam sterilizer (autoclave), and to keep them as "sterile" dressing materials for medical activities (i.e. dressing, injection etc.)
Drum, sterilizer.
Air vents system to allow steam to circulate freely during the sterilisation cycle.
Lateral air vents system is preferable to top and bottom air vents.
Closing lid with a clip lock.
Material: Austenitic stainless steel, smooth surface.
External diameter: approx. 150 to 165 mm.
Height: approx. 100 to 120 mm.
Thickness: approx. 0.6 to 0.7 mm.
Carrying handle.
Austenitic stainless steel composition: approx. 8-10 % nickel, 18-20 % chromium.
Reusable.
Water sampling bag, polyethylene, sterile, self-stand-up bag type. The bag has a leak-proof closure with folding tap closing, 100ml and 4oz. Fill lines and a write-on strip.
Water Sampling bags, 100ml capacity, Sterile, Stand-up, easy and safe closing, without Thiosulphate tablets.
It can detect the air pollution and dust storms.
Rated load flow: 5-30L/min;
Electronic timing control, AC and DC dual-use;
Working voltage: 220V AC or DC 10V (8 Section rechargeable battery pack).
Brinell Hardness Tester
....