Flow measurement by paddle-wheel sensor
Generation of disturbance variables by ball valve with scale in pipe section outlet
Experimental unit for control engineering experiments
Flow control in a pipe section
Process variables X and Y accessible as analogue signals via lab jacks
Digital industrial controller, parameterisable as a P, PI or PID controller
Large process schematic on front panel
Rotameter to visualise the flow
Control valve: electric control valve.
AC and DC voltage output: 200mV, 2V, 20V, 200V, 500V, AC and DC current output: 2mA, 20mA, 200mA, 10A
....0N?2N?The product is composed of a spring, a pointer, a scale plate, a pull rod, a suspension device, a clamping handle and a pointer adjustment device, etc., indicating that the value tolerance range is not more than 0.1N, and the return to zero tolerance is not more than 0.05N.
....The product is composed of a glass thermometer, a scale brand and a protective sleeve. Temperature sensitive liquid: red, packed in a warm bulb and a capillary tube. Scale plate: made of thick 0.5mm aluminum plate, scale plate length 500mm, the scale of the line has two kinds of temperature indication, Celsius temperature (symbol?) and thermodynamic temperature (symbol?). Warm bubble: About 135mm, located in the lower end of the thermometer. Capillary: installed in the scale board, the capillary cross-section of the triangle, when the positive observation from the front, there is amplification. Scale range: 0 ~ 100? Scale range: 0 ~ 100 ?, thermodynamic scale of 273 ~ 373K. Each 1o line length is 4mm. Each 1o for the short term, each 5O for the middle line, each 10o for the long term. Showing the value of tolerance ±1?.
....It is used to demonstrate conductivity ability of different electrolyte solutions for senior middle school students. It consists of base demo board, lamp holder, lamp beads and electrolyzer.
....It is used in electron cloud concept teaching of high, middle school chemistry and physics microstructure.
....Power supply: 230 V 1ph 50 Hz 3 Hp
....It is used to demonstrate electrophoresis of colloid and understand cause of formation of electrophoresis. It consists of base power supply device, scaled U-tube, electrode, plug and switch.
....Level control with transparent tank
Level-controlled tank with overflow and graduated scale
Level measurement by pressure sensor
Experimental unit for control engineering experiments
Large process schematic on front panel
Process variables X and Y accessible as analogue signals via lab jacks
Generation of disturbance variables by ball valve with scale in outlet
Control valve: electromagnetic proportional valve
Multi-functional digital industrial controller.
Control valve: electro-pneumatic control valve
Digital industrial controller, parameterisable as a P, PI or PID controller
Large process schematic on front panel
Experimental unit for control engineering experiments
Generation of disturbance variables by needle valve
2 Manometers
Process variables X and Y accessible as analogue signals via lab jacks
Pressure control of a 2nd order controlled system with 2 pressure tanks
Pressure measurement by pressure sensor.
Flow measurement by rotameter with electrical output
Generation of disturbance variables by ball valves with scale
Tank with overflow and scale
Experimental unit for control engineering experiments
Level and flow control individually, and cascaded
Large process schematic on front panel
Key process variables accessible as analogue signals at lab jacks
Level measurement by pressure sensor
Control valve: electromagnetic proportional valve
2 digital industrial controllers, parameterisable as P, PI or PID controllers, cascade.
With the help of thestarting lever, the crankshaft with the connecting rod and the piston can beput into motion with the clutch pulled. Carburettor and clutch can be operated.
The following have been cutaway:
Crankcase
Carburettor
Cylinder head
Cylinder
Transmission
And air filter.
All process variables accessible as analogue signals at lab jacks
Experimental unit for networking of industrial controllers
2 signal generators
Profl bus DP interface card for PC
2 digital controllers, configurable as P, PI or PID controllers, with field bus interface.
Strong Electromagnet
....The working voltage of the instrument is AC 42V, and the inductive demonstration device is a handheld light bulb display.
....Steady Effect Experiment Instrument
....Loading of test bars with weights
Test bars cannot be overloaded
White backing wall with grid patterning
Demonstration of elastic buckling
4 steel test bars
Representation of all cases of euler buckling
Storage system to house the components
The engine can be turned easily. This engineis a 1-cylinder naturally aspirated diesel engine with balancer shaft andbottom-mounted camshaft.
Cutaway are: engine case, injection nozzle, injection pump, cylinder, cylinder head, muffler, starter, air filter and rotor.
Energy Conversion Demonstrator
....Working manner of central plunger
Functions of roller ring and cam plate
Function of shutoff device
Functions of pressure valves
Functions of the mechanical governor
Function of injection timing device.