Sleeve covers provide protection against a wide range of cytotoxic drugs. Elasticated for secure fit
Lightweight low-linting Clean Tough material
Manufactured from lightweight and low-linting Clean Tough material.
Silicone-free.
Education Kit Handbook Additional Guidance on Children with Disabilities. Early Childhood Development Education.
....Education Kit Handbook Additional Guidance on Children with Disabilities. Recreational Activities.
....Education Kit Handbook Additional Guidance on Children with Disabilities. Basic Primary Education.
....Chill-Its Cooling Arm Sleeves provide full arm coverage to absorb and wick away sweat, deliver advanced cooling relief, shield skin from UV rays, and even protect against light abrasions.
Protection from light abrasions
Reflective accents
Anti-odor treatment
Performance knit fabric is soft, stretchable and durable
Wicks moisture when dry to absorb sweat from the body
Instant cooling when wet that can last for hours
UPF 50+ Protection
Machine washable
Chemical-free cooling.
Evaporative Cooling Vest provides cooling relief and comfort once soaked in cold water.
Water-repellent liner and black cotton-poly elastic trim
Lightweight, durable, and washable
Soak in water 2-5 minutes to activate
V-neck with zipper closure
Quilted nylon outer layer
Activated, polymer-embedded fabric inside
Remains hydrated for up to 4 hours
Mesh side panels offer improved ventilation and stretch.
Made of 100% elastic with hook and loop extenders
Chill-Its Phase Change Cooling Vest Extenders provide 3.5 in. (9 cm) of extension when used with the Chill-Its Phase Change Vest.
Comfortable stretch
For use with cooling vests.
Experiments:
Safety control using the high and low pressure switch and flow switch
Plant start-up and system monitoring using the incorporated protection and safety devices
Study and understanding of the operation of a chiller unit
On-off control of the cooled water temperature
Detecting the system operating parameters:
Calculation of thermal balances for the refrigerant and water circuit
Plotting of the refrigerant cycle on a pressure-enthalpy diagram of the refrigerant gas
Experiments:
Study and understanding of the operation of a chiller unit
Detecting the system operating parameters
Plotting of the refrigerant cycle on a pressure-enthalpy diagram of the refrigerant gas
On-off control of the cooled water temperature
Plant start-up and system monitoring using the incorporated protection and safety devices
Calculation of thermal balances for the refrigerant and water circuit
Safety control using the high and low pressure switch and flow switch.
A connection panel that allows open signal access to connect a compatible controller e.g. the PLC Trainer with Software for controlling the training bench operation. The has been designed and manufactured to incorporate all current safety standards. The refrigerant used complies with anti-pollution legislation.
Chiller Units Training Bench with Open Signal Access that is designed to allow the theoretical and practical studies into the operation and use of chiller units and the use of an intermediate fluid (a mixture of water and anti-freeze), for the transport of cooling power form the cooling production plant to the user site.
The allows students to become familiar with plant start-up and operational safety checks, control and system operating parameters and calculation of thermal balances and efficiencies.
Experiments:
Study and understanding of the operation of a chiller unit
Plant start-up and system monitoring using the incorporated protection and safety devices
On-off control of the cooled water temperature
Safety control using the high and low pressure switch and flow switch.
The is designed so students can study the operation and theory associated with chiller units and to study the use of an intermediate fluid for transporting thermal or refrigerating power from the production / storage site to the air conditioning plant. A Chiller Units Training Plant that is designed to study the operation of a chiller and its components. For example the thermostatic expansion valve and flow switch.
The has been designed and manufactured to incorporate all current safety standards.
The refrigerant used complies with anti-pollution legislation.
Faults can be introduced using the Manual Fault Simulator or the Electronic Fault Simulator to allow the students to troubleshoot the faults and diagnose the actions required to set the plant back into the correct and efficient operating condition
Chinas Political Map Model
....Chinese District Splicing and Combination Mo
....Chinese Terrain Model
....Chisel Mortiser Wood working Machine
....The measurement data can be used to estimate the chloride diffusion coefficient of concrete for the service life prediction and design of concrete structures as well as the durability-based quality control of concrete. Laboratory test device for the measurement of the resistance of the concrete against the penetration of chloride.
Features:
Flexible logging interval time (1 to 10 min)
Automatic temperature control system.
Stand alone operation.
Easy-to-assemble.
Accurate (+/- 0.1 mA)
User-friendly PC software.
Customizable setup.
Four measurement channels.
USB connection to computer.
The uses a stainless steel centrifugal pump to provide high throughputsfor efficient cleaning. Achievable flowrates are dependent on the back pressure generated by the system being cleaned.
Operation is simple on/off control which gives the maximum flow ratefor efficient cleaning. Flow rates may be adjusted using a backpressure valve(not supplied)
Capacities up to 4.0 m3/h are achievable with low backpressure systems. Astainless steel splash cover protects the pump from spray during laboratory/pilot plant cleaning. A small footprint and is mounted on a mobile platform meaning that it caneasily be positioned in a lab or pilot environment to meet local CIP needs.
4pc circlip plier set including internal and external bent and straight galvanized tips, lever handle blue and red dip insulated finger protection.
Features:
Internal and external bent and straight galvanized tips
Insulated finger protection.
It is used with electric instruments now in many schools to meet student experiments related circuit in junior middle school electrics basically, and to achieve the goal to train practical ability of junior middle school students.
....The main components are mounted on supports to facilitate their replacement when faulty. The circuit board is attached on a plastic base that protects the solder side and stands on four non-slip rubber legs. The Circuit Board For TRIAC is a circuit board that permits students to learn how to use triacs. The components are mounted on the board so as to view the circuits identified by section.
Educational Advantages:
Designed to be used in experiments dealing with industrial electronic circuits applied to electro mechanics of automated systems.
Allows students to learn industrial electronic circuit operation.
Allows students to measure various circuit points and calculate electrical values.
Allows students to analyze circuit schematics.
Features:
One DC supply section for the time delay and starting circuit.
One time delay and starting circuit.
Allows students to troubleshoot faulty component circuits
One power section with a triac.