Blood collection needle for use with vacuum tubes. For use in clinical phlebotomy.
Blood collection needle.
Sterile, individually packed in a twist-apart plastic container.
Material; Medical grade stainless steel.
Length approx. 40 mm
Diameter 20 G (0.9 mm)
Applicable for multi-sample draw.
Needle fits (screw in and out) needle holder.
Pointed at both ends, with rubber sleeve on the posterior end needle.
Applicable for multi-sample draw
Needle fits (screw in and out) needle holder
Sterile, individually packed in a twist-apart plastic container
Blood collection needle for use with vacuum tubes. For use in clinical phlebotomy.
Material; Medical grade stainless steel
Blood collection needle
Pointed at both ends, with rubber sleeve on the posterior end needle.
Length 25 mm
Diameter 22 G (0.72 mm)
Material: Needle: Stainless steel.
Measurements: External diameter expressed in Gauge and millimetres.
Base and protective cap: medical grade plastic.
Length expressed in inch and millimetres.
Size selected: 19Gx1 1/2” (1.1 x 40mm).
Intended use: inject fluids into, or withdraw fluids from, parts of the body below the surface of the skin.
Material: Needle: Stainless steel
Length expressed in inch and millimetres.
Size selected: 21Gx1 1/2” (0.8x40mm).
Base and protective cap: medical grade plastic.
Measurements: External diameter expressed in Gauge and millimetres.
Sterile
Disposable.
Material: Needle: Stainless steel
Measurements: External diameter expressed in Gauge and millimetres.
Base and protective cap: medical grade plastic.
Length expressed in inch and millimetres.
Size selected: 22Gx1 1/4” (0.7x30mm).
Sterile
Disposable.
Material: Needle: Stainless steel conform to ISO 9626-1:1991.
Measurements: External diameter expressed in Gauge and millimetres.
Base and protective cap: medical grade plastic.
Length expressed in inch and millimetres.
Sterile
Disposable.
Size selected: 23Gx1” (0.6x25mm).
Material: Needle: Stainless steel.
Measurements: External diameter expressed in Gauge and millimetres.
Base and protective cap: medical grade plastic.
Length expressed in inch and millimetres.
Sterile
Disposable.
Size selected: 25Gx5/8” (0.5x16mm).
External diameter expressed in Gauge and mm
Material: Sharp needle, stainless steel, siliconised, for atraumatic insertion.
Butterfly wings, PVC, for better handling and fixation.
Disposable.
Sterile.
Initial sterilisation method: Ethylene oxide gas.
Soft flexible tubing, PUR (polyurethane) or PVC, length approx. 150-300mm, including Luer connector with cap.
Size selected: 21G (0.80 x 20mm) green.
Length expressed in mm
Colour code/external diameter: Visible on the wings.
Components: Needle with protecting cap, wings, tube including Luer lock connector with cap (all parts fit together to form a unit).
Material: Sharp needle, stainless steel, siliconised, for atraumatic insertion.
Disposable.
Sterile.
External diameter expressed in Gauge and mm.
Colour code/external diameter: Visible on the wings.
Components: Needle with protecting cap, wings, tube including Luer lock connector with cap (all parts fit together to form a unit).
Length expressed in mm.
Initial sterilisation method: Ethylene oxide gas.
Soft flexible tubing, PUR (polyurethane) or PVC, length approx. 150-300mm, including Luer connector with cap.
Butterfly wings, PVC, for better handling and fixation.
Size selected: 25G (0.50 x 20mm) orange.
Provide excellent chemical resistance
All edges hemmed
Lightweight with four metal grommets, neck string, and waist ties
Top 2 in. (5cm) of bib is a double thickness of material
Dimensions: 45L × 35 in. W (114 × 89cm)
Thickness: 12.5 oz.
This neoprene sleeve offers a broad spectrum of chemical resistance with added protection from snags and punctures.
Excellent resistance to a wide range of chemicals
Economically priced arm protection for practically every application.
Extremely flexible and light weight for level of protection
Durable and cost effective.
Device is accurate from 0.5 to 4 McFarland units in increments of 0.1 units
Used with Calibration Kit
Instrument can be used for any laboratory procedure that requires inoculum density adjustments
Includes: Nephelometer, AC adapter and 4 AA alkaline batteries (not rechargeable).
The manifolds incorporate pressure tappings which allow the pressure drop across each pipe element to be measured using the four 500-0-500 mm water differential manometer bank. The manifolds also incorporate valved discharge points which allow the network to be configured to represent various distribution systems including a ring main and a long distribution system. The apparatus consists of a network of four coiled pipe elements and a differential manometer bank. The four pipe elements are located between a pair of large bore four branch valved manifolds which allow a number of series, parallel and series/parallel network configurations to be achieved. The Network of Pipes Apparatus has been designed as an additional experiment for use with Hydraulics Bench, which provides the basic service module for the pumping and volumetric measurement of the water supply.
Experimental Networks:
Single pipe
Series parallel network with 3 or 4 elements
Four pipes in series
Four pipes in parallel
Two pipes in series
Two pipes in parallel
A long distribution system with 1, 2, 3 or 4 discharge points
A 3 pipe series network with a parallel bypass
A distribution system with 2, 3, or 4 branches from a common manifold
A ring main distribution system with 1, 2, 3 or 4 discharge points
The Network System can be connected to local networks for remote fault insertion using the Network System. The Network System offers a real world look into the network operation of present day vehicles.
....All process variables accessible as analogue signals at lab jacks
Experimental unit for networking of industrial controllers
2 signal generators
Profl bus DP interface card for PC
2 digital controllers, configurable as P, PI or PID controllers, with field bus interface.
Agitation by variable speed flat blade impeller (variable to 1800rpm)
Working vacuum of 75mm Hg (ABS) with liquid ring vacuum pump
Simple Controls
Surfaces in contact with the process fluid are stainless steel
Compact and self contained
Cooling coil
Pressure leaf filter designed
25 litre vessel designed
Electrical heating element
Extraction pump.
The outer tube is made of ABS engineering plastic, the size of about 100 mm in diameter and 130mm; glass is made of tube diameter, with 60 * 70mm; the upper cover is made of transparent plastics processing, has inserted a stirring stick and a hole; a stirring rod with the diameter of 5mm organic glass rod production. The products are mainly composed of outer barrel, heat insulating sleeve, inner cylinder, cushion cover, upper cover, stirring rod and so on.
....New Energy (Battery Energy Vehicle) Whole System