Vacuum Pump Oil Free
....Section of a diaphragm Servo Brake used for light vehicles, complete with double circuit brake pump.
....The fully functional, sectioned Vacuum Servo Master Brake Cylinder are excellent for demonstrating the operational principles of the vacuum assist process. A handle is attached to the pumping mechanism to demonstrate the function. Key components have been carefully sectioned including the power chamber, booster, slave cylinder, valves and fluid reservoirs.
....Self contained fully operational Petrol and Diesel EngineRigs.
Engines can be supplied with fault insertion boards, thisallows a range of open circuit and high resistance faults to be inserted,designed to aid teaching diagnostics, fault finding and troubleshooting.
Petrol and diesel engine rigs are manufactured to replicatethe engine bay of the donor vehicle.
Complete with start, charge, fuel, air-intake, cooling and exhaustsystems.
The petrol and diesel engine rigs offers an enhancedtraining resource, hands-on training with real components, greaterunderstanding for the student with out the constraints of the modern motorvehicle.
Diagnostic sockets are fitted to the engine rigs asappropriate. Optional Fault Board available.
All rotating parts are fully guarded.
MP lab coats are constructed of a non-woven, microporous, coated material and provide protection in controlled environments.
Liquid chemical resistance
Comfortable, yet durable
Bonded polypropylene with laminate
Low particle shedding
Disposable.
Folded in an inside-out fashion that essentially elimates the individual from contaminating the outside of the garment
VAI Easy2Gown 1700 Cleanroom Hoods are single-use PPE with excellent chemical resistance
Bonded polypropylene with laminate
Piped seams with reinforced stitching
Packaged to prevent operator contamination of the outside of the garment
Excellent chemical resistance.
Breathable 1700 coveralls are made of a heavyweight, non-woven, and high-quality Micro Porous coated material. Disposable garments are extremely tough and fluid resistant.
Piped seams with reinforced stitches
Excellent chemical resistance
Bonded polypropylene with laminate
Sewn thumb loops to eliminate shifting
Disposable.
Heavy weight, non-woven and high quality microporous (MP) coated material
Excellent liquid resistance, especially to chemicals.
MP Knee-High Boots feature elastic tops and ankles and are individually packaged in pairs of two.
Suited for use where maximum protection to product or wearer is required.
Shoe covers are latex and lint free, with a serged bottom seam that is made to be suitable for use in clean environments.
Shoe covers are durable and resistant to liquids
Individually inspected for size, stitching, and workmanship
Latex and lint free.
Elasticized top opening
Skid resistant
Built specifically for use in low traction areas.
Heavy weight, non-woven and high quality microporous (MP) coated material
Suited for use where maximum protection to product or wearer is required
Microporous hood with integrated face mask is individually packaged and suitable for ISO 5 cleanroom environments.
Liquid resistance, especially to chemicals.
Products are mainly composed of the machine base, a motor, a dry with incandescent lamp, organic glass cylinder, accumulator ball, adjusting screw, comb, belt wheel, rubber belt, discharge, discharge ball insulating rod. Instrument can produce tens of thousands of volts potential difference, as the electrostatics experiment of high voltage static power can be used to demo charge properties, distribution; electrostatic induction principle; display power line and tip discharge phenomenon. About 200 x 280 x 90mm.
....Many parts have been chromium-plated and galvanized for a longer life. Vane Compressor Cutaway model is carefully sectioned for training purposes, professionally painted with different colours to better differentiate the various parts.
....Equipment Layout: Standalone
Operated: Manually
Dimensions: 15 x 15 x 20(h) cm
Net Weight: 1 kg
Gross Weight: 2 kg.
The hermetically sealed refrigerant compressor incorporates a brushless three phase DC electric motor that is driven by a variable speed controller. Compressor speed and power supplied is displayed on the PC.
The condenser and evaporator are brazed plate heat exchanger and utilize a large common reservoir of water to minimize changes in water temperature during operation. The refrigerant exiting the compressor passes through a condenser, receiver, filter, variable area flow meter, expansion valve and evaporator before retuning to the inlet side of the compressor.
The refrigeration circuitry includes a water cooled condenser complete with isolating valves, manual expansion valve, evaporator, variable area flowmeter for mass flow of refrigerant, filter/drier unit, sight glass and over pressure cut-out for unit protection. The unit is designed to use Tetrafluoroethane as the refrigerant with a twin cylinder reciprocating compressor, belt driven by the variable speed dynamometer.
The evaporator coil is mounted in an electrically stirred water/glycol mixture contained in a thermally insulated, stainless steel tank. The water/ glycol mixture is protected from over temperature conditions by a thermostat should the heater should be left on when the compressor is not circulating refrigerant. Heating of this water/glycol mix is infinitely variable enabling balanced experimental conditions over a wide range of temperatures to be obtained.
Experimental Capabilities:
Determine the Mechanical, Thermodynamic (Isentropic) and Volumetric efficiencies.
Estimate the rate at which heat is transferred to the system from the surrounding environment.
Determine the energy flows and coefficient of performance for given operating instructions.
Operate the refrigeration unit over a range of conditions.
Estimate the Heat Transfer Coefficient.
Compile an energy balance under light load and full load conditions.
Examine the behaviour refrigerating cycle under variable loads and speeds.
Measurement of amperage and voltage to determine the power at the evaporator
Investigation of a vapour jet compressor
Vapour circuit with pump and vapour generator for operating the vapour jet compressor
Vapour generator with electrically heated water jacket
Transparent tank with water-cooled pipe coil as condenser
Flooded evaporator with float valve as expansion element
Transparent tank with adjustable heater as evaporator
Refrigeration circuit with condenser, evaporator and vapour jet compressor for refrigerant.
Vapour Jet Refrigerator And Heat Pump A simple ejector performs the expansion and compression processes involved in the combined cycles. A small electric motor drives the pump of the Rankine cycle. The heat source is electrically heated and produces high pressure vapour to drive the ejector.
A bench top example of a Vapour Jet Refrigerator And Heat Pump that is driven by a heat source. The unit operates on a combined Rankine and vapour compression refrigeration cycle using a low pressure, non-toxic ozone friendly refrigerant.
Measuring a vapour pressure curve for saturated vapour
Bourdon tube pressure gauge to indicate pressure
Digital temperature display
Boiler with insulating jacket
Temperature limiter and safety valve protect against overpressure in the system.