New Energy (HEV) Whole System Electronic Engineering Lab
....New Energy (HEV) Whole System Troubleshooting and Testing Platform
....New Energy Pure Electric Powertain Disassembly and Assembly Training Platform
....New Energy Pure Electric Powertain Disassembly and Assembly Training Platform Electronic Engineering Lab
....Material of the simulator: Thermoplastic polyurethane - TPU (primary material for body skin), Poly vinyl chloride - PVC (primary material in chest and face skin) silicone rubber, Polyoxymethylene - POM, polypropylene - PP, and iron/steel.
Realistically sculpted to resemble and simulatea baby, anatomically accurate and feeling smooth / resilient / bony as relevant and suitable for simulation. Full term anatomically accurate newborn with umbilical cord
Texture of the simulator: soft and smooth, friction free to demonstrate the desired procedures.
Material of the simulator: Thermoplastic polyurethane - TPU (primary material for body skin), Polyvinylchloride - PVC (primary material in chest and face skin) silicone rubber, Polyoxymethylene - POM, polypropylene - PP, and iron/steel.
Full term anatomically accurate newborn with umbilical cord.
Texture of the simulator: soft and smooth, friction free to demonstrate the desired procedures. Realistically sculpted to resemble and simulatea baby, anatomically accurate and feeling smooth / resilient / bony as relevant and suitable for simulation.
Full term newborn size manikin with soft, life-like skin and moulded hair. Transparent chest allows direct observation of ribs, heart and superior vena cava.
Facilitates training of following skills:
Central venous cannulation through cephalic and saphenous vein punctures.
Tube feeding and gastric suction.
Translucent skin allows visualization of underlying veins.
Correct anatomical position of basilic, cephalic, jugular and subclavian veins.
Full term newborn life-size manikin with realistic anatomical features. Fully articulated head, neck and jaw with tongue. With soft, lifelike skin and moulded hair.
Features: Head tilt/chin lift to open the airway; Realistic chest rise on positive pressure ventilation; brachial artery pulse examination point.
Life-size newborn arm. With realistic anatomical features such as: medial venous structures; veins on the dorsum of the hand; radial and brachial arteries.
Easily replaceable resealing skin and veins withstanding multiple needle sticks. Realistic “pop” when needle enters vein.
Squeeze bulb to simulate collapsed and normal veins.
The trainer is easy to work on and all major components, wiring and connectors match OEM configuration. The trainer is mounted on a mobile stand constructed of 2 (5 cm) tubular steel equipped with four 5 (12.5 cm) phenol casters (2-fixed and 2-swivel w/locks). The Newer Ram Cummins Diesel Engine Bench With SCR trainer is a fully operational engine mounted on a mobile stand. The trainer is based on 2013 & newer Ram Truck w/Cummins 6.7L global engine platform. Students can perform many related Engine Trainer is equipped with safety guards covering all rotating components. Performance and Electrical/Electronic tasks using this trainer.
Educational Advantages:
Equipped with all OEM equipment related to EPA 2010 Emission Standards (with SCR)
Engine system responds to inserted faults with real world symptoms, OEM DTCs and check engine light operation
Demonstration of systems to groups of students without the access limitations of a complete vehicle
Features:
High pressure common rail fuel system (Bosch)
Integrated ECM breakout box with test points for oscilloscope and hookup
Breakout box terminals identified with OEM terminology and numbers
Diesel Particulate Filter (DPF)
Automatic transmission
Data link connecter for scan tool hookup
Exhaust Gas Recirculation (EGR)
Closed Crankcase Ventilation System
Diesel Oxidation Catalyist (DOC)
Selective Catalytic Reduction (SCR) w/ DEF injection.
Effective diameter 25mm, Newton ring imaging can be adjusted.
....Newtons Second Law Demonstration Instrument
....Maximum protection at affordable cost
Bib-style apron provides coverage of front and sides
With bound neck and ties
NexGen is liquid resistant and provides a true aerosol barrier, with >99% holdout of particles down to 0.35μm. Proprietary microporous technology gives aprons effective protective properties at an economical price. Perfect for applications involving nontoxic liquid or spray hazards.
Apron
Length: 36 in. (91cm)
White.
Nine Row Mechanical Seeder Cutaway model is carefully sectioned for training purposes, professionally painted with different colours to better differentiate the various parts.
....Class 10 Cleanroom Gloves, ambidextrous, non-sterile, chemical resistance to a range of common chemicals and substances.
Class 10
Powder free, latex free
Beaded cuff
Nitrile
Color: White
Non-sterile
Ambidextrous
Greener Choice Claims
Environmental benefits include:
Free-of a substance that causes environmental harm.
Class 100 Cleanroom Gloves, ambidextrous, non-sterile, chemical resistance to a range of common chemicals and substances.
Class 100
Non-sterile
Powder free, latex free
Color: White
Nitrile
Ambidextrous
Beaded cuff.
Class 100 Cleanroom Gloves, ambidextrous, sterile, chemical resistance to a range of common chemicals and substances.
Sterile
Powder free, latex free
Beaded cuff
Class 100
Hand specific, anatomical shape
Nitrile
Color: White
Greener Choice Claims
Environmental benefits include:
Non-Toxic.
Free-of a substance that causes environmental harm.