This radiation does not produce heat, it does not alter the tissues and it is not felt by the patient that is under therapy. It performs an anti-inflammatory and revitalizing action. I.R. (Infrared Radiation) is a beam of non visible, unidirectional and monochromatic light (since it is emitted in the infrared band) that transfers remarkable amounts of energy represented by photons
Theoretical topics:
Features of the Laser
Introduction to the Laser
Semiconductor Laser
CO2 Laser
Circuit blocks of Laser Therapy
Typical circuit of an IR Laser
Main applications of the Laser Therapy.
Laser Welding Machine
....The diameter is 4-6mm, in the chemistry laboratory, the latex tube generally uses with the gas derivation, the different instrument connection and so on, but not suitable for the high temperature experiment, like distillation and so on.
....Features a filament covered, unexposed elastic band for secure fit and closure
Disposable SPP beard cover
Manufactured with 100% non-linting, non-woven, spunbond polypropylene fabric
Tested and manufactured in ISO compliant facilities under individual inspection and strict process
Manufactured with 100% non-linting, non-woven, spunbond polypropylene fabric to provide comfort and protection. Recommended for Class 10,000 (ISO 7) cleanroom environments.
Recommended for use in a cleanroom Class 10,000+ (ISO 7+) critical environment.
The prime meridian plane is arranged in the fixed plate and the equatorial plane plate, and can rotate the plane meridian and latitude pointer.
A hollow net ball consisting of 24 meridians and 9 parallels.
The ball is a positive sphere, diameter 320mm, mounted on the stent.
Raised latrine kit for use in urban areas and on hard or flooded ground where impossible to dig a pit, composed of an above ground base with sludge tank, access ramp and elevated latrine slab, supporting its latrine superstructure.
....Used for communal latrines, health centres, feeding centres, schools etc., it is composed of a double Superstructure with lockable doors, roof/cover and natural ventilation/aeration. The kit is easy to assemble to provide a stable and durable installation for a block of two (2) latrine stances/cubicles in emergencies.
Being supplied complete as a double cubicle, it has two adjacent latrine cabins per set, while the latrine slabs are supplied independently of this kit.
The kit shall be complete, ready to install, and not requiring any materials to be sourced in country for the initial installation. (However it is allowed to foresee the design for later repairs with local available materials).
The overall structures shall be of lightweight, rigid, durable and sturdy design, climatically stable and resistant to withstand heat, wind, dust, rain and manual cleaning, including stronger windy conditions.
The kit is easy to assemble to provide a stable and durable installation for one latrine stance/cubicle in emergencies. Used for family or communal latrines, health centres, feeding centres, schools etc., it is composed of a Superstructure with lockable door, roof/cover and natural ventilation/aeration.
This complete latrine cabin kit is for deployment with e.g. trench latrine installations, or with single slabs.
The overall structures shall be of lightweight, rigid, durable and sturdy design, climatically stable and resistant to withstand heat, wind, dust, rain and manual cleaning, including stronger windy conditions.
Being supplied complete as one single cubicle, it is designed to be installed either as single cabin or in groups of more adjacent latrine cabins. The latrine slabs however, are supplied independently of this kit.
The kit shall be complete, ready to install, and not requiring any materials to be sourced in country for the initial installation. (However it is allowed to foresee the design for later repairs with local available materials).
A small-scale accessory that allows experimental investigation of linear heat conduction and the measurement of the thermal conductivity of various solid conductors and insulators.
The hot end uses a nominal 65W heater (operating at 240v maximum), which is fitted with a high temperature limit switch. The power supplied to the heater is controlled and measured by the Heat Transfer Service Unit .
The cold section is of identical dimensions to the hot end and is water-cooled. Both the heated and cooled ends are each fitted with three thermo couples at 15mm intervals to measure the temperature gradients along the bars.
An insulated, 25mm diameter brass heated section and cooling section that may be either clamped together, or assembled with one of four insulated intermediate sections or test specimens between the interfaces.
LCR Circuit, LCR Circuit Equipments, LCR Circuit Tools, LCR Circuit Tool Kits, LCR Circuit Manufacturers, LCR Circuit Suppliers from India, China, Kenya
Lab Tender Suppliers Africa and Lab Equipment Africa Kenya, Tunisia, Uganda, Sudan, Algeria, Morocco, Angola, Ghana, Gabon, Lesotho, Zambia, Chad, Somalia, Senegal, Zimbabwe, Guinea, Rwanda, Benin, Burundi, Guinea Bissau, Equatorial Guinea, Mauritius, Eswatini, Djibouti, Reunion, Comoros, Cape Verde, Western Sahara, Tanzania, Togo, Sierra Leone, Libya, Congo, Central African Republic, Liberia, Mozambique, Madagascar, South Africa, Ivory Coast, Cameroon, Niger, Burkina Faso, Mayotte, Sao Tome, Seychelles, South Sudan, Mali, Malawi, Nigeria, Ethiopia, Egypt, DR Congo, Mauritania, Eritrea, Gambia, Botswana, Namibia
....Max. Tapping Capacity: M 10 M 20 M 30
Spindle Travel: 100 120 140
Spindle rpm: 600.1000.1500 Optional Optional
Motor HP: 1 2 3
Spindle Transmission: Lead Screw Lead Screw Lead Screw.
Set of leads for connecting the terminals of the modules.
....Leaf Area Meter Non- Destructive
....Integration skills across multiple stations as well as skills specific to an individual station are covered in the balance. Overall system skills include discrete I/O handshaking, system start-up/halt, system stop/reset, and FMS programming. The first two LAPs concentrate on skills core to all stations: an introduction to mechatronics, systems concepts, safety, machine operation, sensors, pneumatic pick & place, and electrical pick & place. Stations can also be mixed and matched, enabling instructors to build and change the system as budgets allow or needs change. Stations can be easily moved apart to function as individual workstations by releasing two quick connects and one plug-in cable. Many station combinations are available to support your needs. All mechatronics stations teach operation, sequencing and programming skills.
Features:
Operation, sequencing, and programming skills
Optional Online eBooks
Introduction to Mechatronics
Discrete I/O handshaking
Student Reference Guide.
Leather Protectors Glove
....Trusted measurement for high turbidity applications; simplified. Improved and intuitive design A smart device for more reliable measurements Easy to use. Easy to Be Right. The new laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding wastewater and industrial applications.
A smart device for more reliable measurements
The ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability. This quality step removes subjectivity and the need for repeated measurements.
Easy to use. Easy to Be Right
The provides everything you need at your fingertips. With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, it easy to Be Right.
Improved and intuitive design
The large full colour touch screen display and intuitive user interface accelerate setup, calibration and measurement. An easy interface and guided procedures give you confidence in your results.
Portable baby/child length-height measuring board is used to measure:
a) Recumbent length of a baby up to 24 months old.
b) Height of a child aged 24 months and up in vertical position.
Has a firm, flat surface.
Carrying when collapsed is facilitated by an integrated handle at point of equilibrium and removable shoulder/back strap/s.
Fixations of the shoulder/back strap/s on the board do not hamper horizontal set-up from lying flat.
Fold-up mechanism and low weight make it compact and easy to transport.
Parts are not losing or shaking during transportation.
Panels are secured with self-contained, spring loaded bolts or spring clasps.
Orientation of numerals on the measurement scale: parallel/vertical to the board, facilitating quick and easy reading of results.
Simple and fast set up, no tools (screwdriver, etc.) required.
No need for calibration, as all parts has prefixed position.
Long-lasting hard-wearing measurement scale is fully integrated with the device and is easy to read in low light conditions.
Measurement scale is made of metal.
Unit of measure: centimetres
Accuracy: ±0.2cm
Precision: ±0.2cm
Width of the board: ca. 25cm.
Smallest graduation: 0.1cm.
Measurement range: 0-120cm.
Baby, child and adult portable length/height measuring system consists of a) portable baby length measuring board and b) portable child/adult height measuring board; made of durable plastic, not stand alone, but requiring a wall/hard structure to lean against to ensure stable measurement.
Portable baby, child and adult length/height measuring system.
Portable baby/child/adult length-height measuring board is used to measure:
a) Recumbent length of a baby up to 24 months old, or from a minimum length of 8cm
b) Height of an adult and a child aged 24 months and up in vertical position.
Has a firm, flat surface.
Simple and fast set up, no tools (screwdriver, etc.) required.
No need for calibration, as all parts has prefixed position.
Long-lasting hard-wearing measurement scale is fully integrated with the device and is easy to read in low light conditions.
Orientation of numerals on the measurement scale: parallel to the board, facilitating quick and easy reading of results (refer to the picture attached below).
Fold-up mechanism and low weight make it compact and easy to transport.
Parts are not lose or shaking during transportation.
Panels are secured with self-contained, spring loaded bolts.
Measurement scale is made of metal or another material with equivalent stretch and tear resistance characteristics.
Carrying when collapsed is facilitated by an integrated handle at point of equilibrium and/or removable shoulder/back strap/s.
Fixations of the shoulder/back strap/s on the board do not hamper horizontal set-up from lying flat.
Unit of measure: centimetres
Measurement range with one extension only: 0 to 142cm.
Accuracy: ± 0.2cm
Precision: ± 0.2cm
Smallest graduation: 0.1cm.
Full measurement range with two extensions: 0 to 204cm
Width of the board: ca. 25cm.