The display measures up to four forces from sensors on many of the experiments inthe Structures range. A four-way selector switch selects the displayed force. The Digital Force Display fixes to a Structures Test Frame. This keeps the experiments tidy and saves space around the work area. Includes an output tothe Automatic Data Acquisition Unit. When used with the, the Digital Force Display outputs all four force signals at the same time to the Structures Software. The display automatically adjusts its range to the force.
....The precise actuator collaborates with the intelligent Test Live computer testing software to ensure the completeness and precision of the test results. his product is integrated with a high-stiffness frame. The actuator cylinder comes out in 100mm, 150mm, 400mm and many other models. he crossbeam is hydraulically driven to adjust the test space. The rated load of the main frame ranges from 5 to 25kN or 50 to 1000kN.
....Digital Display Direct Current
....The test adopt high accuracy and digital speed system, precision decelerate structure and precision drive screw ball to realize the max range of test speed. During the testing there is lower noise and smooth operation.
This machine equips alternating servomotor for driving crosshead and imported photoelectric encoder for displacement measure. This machine is accompanied with the digital multi-channel closed loop control system, which apply with the latest measurement and control systems with lots of advanced professional and technical development.
It can achieve the adjustment of crossheads speed when clamp the specimen.
Adopt the USB connector . it can connect the computer to achieve the datas memory, analyze, print and display.
Touch button operation, LCD display screen. It includes test methods display screen, test force display screen, test operation and result display screen and curve display screen. Its so convenient and fast.
The Digital Strain Display accepts up to 16 channels from strain gauges connected in quarter, half or full bridge. The display is fully programmable to match the strain gauges and their bridgeconnections. The display includes precision internal make-up resistors towork with half bridge connections if needed. For quarter bridge connection youneed suitable external make-up resistors or dummy gauges. For use with most types of metal-foil strain gauges, the Digital Strain Display connects to most types of strain bridge connections togive direct readings of strain. Two channels includeadditional individually adjusted dynamic outputs. They can connect to suitable instruments, such as an oscilloscope or a chart recorder for measurement oftransient strains. Alsosupplied is a tool that crimps the connectors to the cable. The connectors areself-locking, reliable, and secure and need no soldering. Supplied with the Digital Strain Display is a reel of cableand connectors to fit the input sockets of the Digital Strain Display.
Channels:
Channels 15 and 16 may also be used for dynamic strain output. Sixteen all channels may be used for slow-changing or staticstrain measurement.
Automatically sustains when it reaches the specified value.
Capable of sustaining at the maximum torque, rotation and grip load.
Dynamic display of torque, rotation and real-time testing curve on the screen.
Support saving, instant retrieving and inspection of testing results.
Capable of re-analyzing test data and curves, and partial zooming of testing curves at will.
Support for data searching. Returns the corresponding data at y-axis when entered the coordinate at x-axis.
Support Excel report templates and customized editing of test reports.
Integrated with travel limit protection and full-scale overload protection.
Control over loading speed of torque and rotation, no stepping for loading speed.
Support for setting a target value on torque, rotation and grip load at will.
Options for displaying curves including torque-rotation, torque-grip load, grip load-rotation.
The unit has an integral liquid crystal display with a scroll switchthat allows all 32 channels to be viewed in groups of four at any time. Theconditioned outputs of the pressure sensors, and any other connected compatibleelectronic instruments, may be output to Versatile Data Acquisition System toallow computer based data acquisition and display. The 32-Way Pressure Display Unit is an optional ancillary tomodular Subsonic Wind Tunnels. The unit mounts onto the control and instrumentationframe of the wind tunnels. Connection to each of the 32 calibrated pressuretransducers is via quick-release pressure inputs mounted on the front panel ofthe unit. It measures and displays up to 32 pressures frommodels, Pitot-static tubes and other measuring instruments fitted to a windtunnel. It is ideally suited to applications where multiple pressuremeasurements are required, for example in boundary layer and tapped aerofoilmodel investigations. This allows easy and quick connection between the unit and anexperiment mounted in a wind tunnel. When the 32- Way Pressure DisplayUnit is used with the system it allows laboratory time to be used more efficientlybecause data can be captured and processed much more quickly than when usingmanual techniques. All pressures are measured with respect toatmosphere. Using enables accuratereal-time data capture, monitoring, display, calculation and charting of allrelevant parameters on a suitable computer. This option providessignificant experimental advantages over conventional instruments such asmanometers. The facility in the software to average data to remove thefluctuations inherent in wind tunnel measurements enhances the quality of theresults by making their interpretation much easier.
....TFT true-color LED screen to display current rotation, target rotation turn and configured speed.
No stepping in speed adjustment. Automatic data recording. Rotation speed and turns configurable.
Equipped with translucent safety shield to prevent specimen from popping out when it breaks.
More reliable hydraulic gripping means for wires in large diameter.
Automatic stop when reaches target rotation turns or specimen breaks.
Distance between grip jaw continuously adjustable by moving the ball screw.
Stably and reliably controlled through human interface and PLC.
Stainless table makes it easier to clean.
A low range strain gauge transducer measures the positive or negative force caused by the torque reaction produced when swirling air is straightened by the honeycomb. This torque is normally calibrated over a small range for higher accuracy.
The display unit contains the signal conditioning electronics in a rack mounting module.
The front panel carries the 4 digit LED display, a main on/off switch and zero and span potentiometers. The rear panel connections include a 10V analog signal for connection to the data acquisition system.
The matrix is connected via a torque to a strain gauge transducer which is calibrated by suspending weights over pulleys either side of the torque arm.
The length of torque arm is such as to enable torque values up to 0.1Nm to be The unit shall be arranged for flow in an upward and downward direction and is supplied complete with adaptor plate having a pilot bore of diameter 50mm.
Swirl meter comprises a Honeycomb matrix mounted within cylindrical housing.
The dimensions of individual cell of the matrix being suitable for arresting the swirl of the incoming air
Consists of a fabricated steel frame bench mounted on casters, which house the major components Control, instrumentation and data acquisition is mounted on the frame in one 3U high, 19 wide electronic rack enclosure.
Intended for use with port models with a nominal free air capacity of 50 litres/second.
It is used for blowing or drawing air through the cylinder head port model. The mode of control may either be direct fan speed set point or by the test piece pressure drop set point. A variable speed centrifugal fan/blower unit, capable of 100mBar static pressure and a flow rate of 300m/hr, is attached to a base plate on the bottom level of the frame.
Used for capillary blood collection
In-built mechanism to retract needle tip preventing reuse or injury.
Instant trigger launches spring-based blade.
Sterile, disposable.
Blade depth approx. 2.0mm.
Instant trigger launches spring-based blade
In-built mechanism to retract needle tip preventing reuse or injury.
Used for capillary blood collection.
Blade depth approx. 2.4mm
Single-use disposable
Sterile.
Disposable nitrile gloves, powder free, non-sterile, ambidextrous
Ambidextrous with beaded cuff
3.5 gm nitrile gloves
Color: blue.
Deflectometer With Telescopic Tubular Displacement Transducer instrument grants very accurate and reliable test results with data acquisition through Datatronic 7 output to PC for processing, printing and file. Deflectometer With Telescopic Tubular Displacement Transducer Used to determine the deflection under known loads of bridges, ceilings or any suspended structure. One telescopic deflectometer consists of:
Aluminium telescopic tubular anodized frame having 1080 mm mimimum height and 3120 mm maximum extension.
Stainless steel chain, 10 m long for measurements over 3 m.
Linear potentiometric displacement transducer with spring system, fixed on the base of the telescopic tubular frame, with measurements either in compression or tension, +/- 50 mm stroke and 0, 01 mm resolution.
Stainless steel base for anchoring the tubular with ballast, hook, accessories.
Carrying case.
These disposable polypropylene gowns are used to protect the wearer from contact with potentially infectious liquid and solid material.
Disposable spunbonded polypropylene isolation gown.
Greener Choice Claims
Environmental benefits include:
Non-Toxic.
Free-of a substance that causes environmental harm.
A three-dimensional stand which consists of three Plexiglas planes has a receptacle for the precision-manufactured models. The associated view can be inserted on each plane of the stand, enabling a direct comparison between the workpiece and the drawing. One shape is made from Plexiglas in order to develop an understanding of invisible edges. The other shapes are made from aluminium. All parts are clearly laid out in a case. The model shapes are precision-manufactured, so measuring exercises can also be carried out. The three-dimensional display is an educational concept for beginners in technical drawing. The student must cut out and fold a template drawing to construct a model. The model set includes ten shapes, involving differing degrees of difficulty. Comprehensive and well structured instructional material makes the training system immediately usable in lessons. For optimal learning, it is recommended that students work independently from each other on these exercises. Two students can easily work with one model set.
....Provides light-weight, impervious protection against bio-hazards, with non-linting construction for greater comfort.
Superior physical properties over imports
In compliance with FDA requirements and tested in accordance, including breaking load, tensile strength, and elongation
Successfully tested for liquid and aerosol blood resistance, synthetic blood penetration and resistance, bacteriophage penetration resistance
Redirects stress to the film material not the thermal seals to minimize breakage potential
Provides liquid and aerosol blood resistance
Full-length open back affords better comfort and shoulder coverage
Lightweight, non-linting construction.
XL size with easy, tear-away feature for quick gown removal and safe disposal
Contoured thumb loops secure gown sleeve for added protection.
The Disposable Protective Lab Coat is anti-static treated and can be used in light duty applications.
Designed for light duty applications.
Offers a barrier against non-hazardous particles and liquid splashes.
Breathable, lightweight material.
Anti-static treated.
Knitted cuffs.
Zip fastener.
Operating Conditions:
Operating environment: Laboratory
Operating relative humidity range: 80% at temperatures < 31C decreasing linearly to 50% at 40C
Operating temperature range: +5C to +40C
Storage temperature range: 25C to +55C (when packed for transport).
Disposable frocks that are optimized for comfort, softness and breathability
Spun bond melt blown spun bond (SMS) material
Designed for workers in a range of industries for nonhazardous dry particle applications
Enclosed elastic wrists
Snap closure (six plus one adjustable)
Mandarin collar
Set sleeves
Serged seams
White.
The Cutaway Over Center Variable Displacement Pump trainer is an application that can be chosen to demonstrate the operation of a hydraulic over-center pump.
Educational Advantages:
The pump housing is cutaway to expose the internal components
The barrel is cutaway to expose the pistons
The rear cover is cutaway to expose the pressure relief valve
The pump is lightweight and easy to handle
The swash plate moves
Large knob on output shaft makes it easy to rotate
The charge pump housing is cutaway to expose the charge pump and the charge pressure relief valve
Includes stand.