Touch screen control for ease of use
Units capable of up to 200 l/hr on special request
Process temperatures up to 150°C
Compact, mobile, easy to install
Continuous and batch operation
Standard throughputs from 30 to 100 l/h (dependent on conditions)
Automatic product divert with temperature on tubular heat exchanger
Built in clean in place (CIP) and sterilisation in place (SIP) facilities
Plate and tubular heat exchanger options
Controlled product preheat and heating temperatures
Simple and rapid switch over between heat exchangers
Capable of aseptic operation
Membrane control console
Fully instrumented
Preheating by hot water (indirect)
Heating by steam (indirect)
Integral USB data logging
Electronic flow meter option.
Two-stage cooling option.
Vapour Jet Refrigerator And Heat Pump A simple ejector performs the expansion and compression processes involved in the combined cycles. A small electric motor drives the pump of the Rankine cycle. The heat source is electrically heated and produces high pressure vapour to drive the ejector.
A bench top example of a Vapour Jet Refrigerator And Heat Pump that is driven by a heat source. The unit operates on a combined Rankine and vapour compression refrigeration cycle using a low pressure, non-toxic ozone friendly refrigerant.
Air Conditioner Installation And Maintenance Training Device can be used to train students to master the theoretical knowledge and practice skills of design, installation, commissioning and maintenance of air conditioning system.
....Straight Edge 300 MM long galvanized steel, to level the concrete.
....The Geothermal Troubleshooting Learning System uses an exposed component layout so that learners can see each component's role in a geothermal system. Learners can easily observe, monitor, and test each component mounted and labeled on a vertical panel. Geothermal Troubleshooting Learning System is equipped with premier electronic fault insertion program for teaching troubleshooting skills. In addition to troubleshooting, the interactive multimedia curriculum and hands-on skills will teach startup, operation, shutdown, and maintenance of a geothermal system. Using, learners troubleshoot electrical, mechanical, and fluid-based faults to become effective real-world experts on residential and commercial geothermal systems. Also includes pressure and temperature gauges at key points to show the system's performance at a glance. Additionally, the system includes a custom designed, temperature-controlled ground simulator so the system can run continuously. Sight glasses installed in the Geothermal Troubleshooting Learning System allow the learner to see the refrigerant's changing state as it passes through the system.
Features:
Industry Standard System Components and Features
Ground Simulator Allows Continuous Training
Geothermal Troubleshooting with Desuperheater Learning System
Fault Pro: Electronic Fault Insertion Software.
The trainer is supplied with an exhaustive manual including a technical description of all the components operating and maintenance instructions and many exercises.
The unit Basic Pneumatics Trainer is the economic version of the Modular Pneumological Tutor.
The unit is made of painted steel plate and can be utilised on any support bench.
The unit requires an external pneumatic supply. A compressor is supplied as a optional.
The unit has been designed to study and experiment the fundamental pneumatics.
Stirred tank with secondary clarifier
Anaerobic degradation of organic substances
Temperatures in the stirred tank and the uasb reactor can be controlled
Control of the pH value in the UASB reactor
Uasb reactor with separation system
Single stage or dual stage operation mode
Separate supply unit with tanks for raw water and treated water.
The unit is assembled in an anodized aluminum profile structure, with painted steel panel.
....The demonstrates how energy can be saved by regulating compressor rpm and fault simulation switches allow students to diagnose.
A Domestic Air Conditioning Training Unit with Inverter for investigating the hydraulic, mechanical and thermodynamic operation of a split-type air conditioning system equipped with an inverter.
The has been designed and manufactured for safe operation in the laboratory environment and the refrigerant used is a which complies with current legislation.
Students investigate the refrigeration system, mechanical operation and thermodynamic cycles of a split-type air conditioning system with an inverter and understand how changes at different parts of the system affect efficiency.
The apparatus consists of an open channel of rectangular cross section supported at its inlet end by a reservoir tank, and at the outlet end by a frame. A number of test models are provided along with an ink injector to allow streamlines to be observed. This Flow Channel provides a low cost experiment with an easy to set up and use operation. The nominal dimensions of the channel are 20 mm x 150 mm x 650 mm long. The channel walls are made from clear acrylic plastic so that full visibility of the flow characteristics can be achieved.
Experimental Capability:
Study of flow over triangular hump section, demonstration of approximate Specific energy - Depthâ„¢ relationships, comparison of theoretical and experimental values of critical height
Study of flow with variable head inlet and variable head outlet using the adjustable outlet orifice
Visualisation of flow around objects through the injection of ink into the flow
Study of flow under a sluice gate (undershot weir).
This hands-on training program is designed to offer the student a thorough job orientation and skill development for the front-end servicing of vehicles. The Four Wheel Suspension Steering Brake Program system offers complete alignment concept flexibility. from basic front wheel alignment (on the trainer); to a complete four wheel alignment on passenger can.
....Intended use:
PCR plate to be used on most standard Thermocyclers, RT PCR platforms, DNA Sequencers.
An electrically-powered device designed to deliver high-flow (exceeding peak inspiratory flow) heated and humidified ambient air or air/oxygen to a neonatal patient as part of noninvasive ventilation (NIV); it may additionally be used with a water tank to produce bubble continuous positive airway pressure (bubble CPAP).
Continuous Positive Airway Pressure (Bubble CPAP) system for the non-invasive respiratory support of normal, premature or low-birth weight neonate with spontaneous breathing. The unit has an integrated pulseoximeter to measure the level of arterial oxygen saturation in blood.
It consists of a gas flow generator that entrains room air, an oxygen input, a heating element, and humidification chamber; it does not include CPAP controlling pressure sensors (i.e., not a full CPAP unit). It is intended for use by a healthcare provider on a spontaneously breathing patient in hospital settings.
Long cuff gloves for gynaecological and obstetric procedures to protect both patient and medical staff from cross-contamination. Gynaecological gloves are sterile and strictly SINGLE USE.
Gloves, gynaecological, latex, powder-free, size: medium, sterile, single use, pair.
Digital weighing scale to weigh adults and children, weighing capacity up to 250kg, with 100g graduation. Powered with customer replaceable batteries. The scale allows a child's weight to be measured while being held by an adult.
Measuring range 0.1 to 250 kg.
Accuracy: ± 100 g over the entire range of measurement.
Graduation: 100 g.
Portability: Easy to carry by a health worker in the field. Maximum weight 4.0 kg (including batteries); maximum dimensions:360 mm for length, 400 mm for width and 70 mm for height.
Mother-child mode is the default mode, alternative mother only mode can be activated by pressing an operational button.
Taring: Taring function is automatically initiated, without pressing any operational button. Taring function is initiated once a parent holds a child after being weighed first (mother child mode).
The on/off button does not serve any other purpose and is encased to be protected from rain, dust and humidity.
Main on/off button has a feature to prevent accidental switching on or off and is easily accessible.
Power saving feature automatically turns off the scale after 4-6 minutes of non-use.
A set of reusable, washable sanitary pads for menstrual protection to be used and reused for a duration of minimum one year.
Each set is comprised of:
2 Holders made of cotton
1 pouch for storage
3 Winged Pads
2 Straight pads
Pad material:
The holders have ribbon bands with edges well stitched by over-locking or other adequate fixation to secure the pads in position.
Pads are made of cotton, preferably flannel, for high absorbance on one side, and synthetic material on the flip side for protection against leakage.
Colors: grey or light brown.
The Temperature Alarm Apparatus Kit
....Double metal sheet structure with needle; diameter≥100mm, meassuring range: 0%RH-100%RH, Temperature: -10???45?, meassuring error rate: the middle part≤±2RH, the others ≤ ±5RH.
....Digital Astronomical Telescope
....Dimension (L*W*H CM): 30*30*215
....