The mobile workstation is equipped with silkscreened labels for component identification; storage/inventory of clamp meter; digital meter; and storage for consumables, including wire and conduit, directly at the workstation. The Solar Photovoltaic Installation Learning System includes a mobile workstation with solar photovoltaic components, PC-based interactive, multimedia student curriculum; installation manual, and teachers guide.
Solar Photovoltaic Installation Learning System teaches students the installation and commissioning of grid interactive and stand-alone photovoltaic systems for commercial and residential applications. The demand for qualified Solar Technicians is rising, as more consumers and businesses apply solar energy in their communities. Students will learn how to develop and implement a site layout; select and install wiring; calculate PV circuit voltage and currents; and install real world components in PV systems, just as they would do on the job.
Features:
Interactive Multimedia Curriculum
Efficient, Effective, and Safe Training
Installation Skills Practice
Two Real-World installation Processes
Additional Requirements:
Solar PV Hand Tool Package
Solar PV Array Station
Consumables Package.
The tear down engine is used for hands-on training for the dis assembly and re-assembly of engine parts and sections. The engine stand allows easy positioning of the engine during work. The stand includes casters that allow convenience in moving the engine as desired. The students can also perform engine inspection. In conjunction with our engine cutaway, students can gain a thorough familiarization with engine construction and assembly.
Engine Features:
Length: 45 inches
Diameter: 17.7 inches
Type: Turbojet engine
Combustors: annular
Turbine: 2 stages
Dry weight: 410 Lbs. approx.
Compressor: 8 stages axial.
Aircraft Brake System Trainer is a training aid that displays two functional brakes representing multiple-disk brake and single disk brake. The trainer also demonstrates the functionality of parking brakes. The system is mounted on a display stand with caster wheels for easy mobility. The system includes Master Cylinder,Reservoir, Parking Brake Valve, and a Selector Valve which allows the selection of any of the two brakes for operation by the Brake Pedal. The students can be taught how to bleed the brakes. Also, the instructor can explain the procedures for the maintenance of brake system.
Features:
Ergonomic design
Hydraulic Reservoir
Parking Brake Valve
Master Cylinder
A complete and functional single-disk brake system.
A complete and functional multiple-disk brake system
Selector Valve to choose one of the two brakes for operation / demonstration
Dimensions: 32 Wide x 19 Deep x 48 High.
The trainer includes secondary radar equipment, and radio navigation equipment. The may be upgraded with the optional feature to include satellite navigation(GPS). The Aircraft Navigation Systems Trainer consists of fully functional aircraft navigational equipment used in a typical general aviation aircraft. The trainer is a realistic mock-up of aircraft navigational systems with functions and capabilities that facilitate the following aspects of hands-on training:
Test the equipment using simulated navigation/flight data in compliance with standard technical procedures.
The emphasis in design is to allow the students gain hands-on experience.
Conduct practical training for flight line tasks like physical removal, installation, operation, and maintenance testing by using ramp tester.
Perform diagnostic testing as done in an avionics maintenance shop, using real time navigation transmission and reception with aDME/Transponder bench test set.
Upper beam an be adjusted in height. Foreseen of fast approach device of the base plate and electric end of stroke switches of the load plate to save the machine from wrong manipulations. CBR loading machine motorized 50 KN ASTM version 1,27 mm/min Load is applied through a screw jack driven by an electric motor at a constant penetration rate of 1,27 mm/min achieved by a built in gear box and assured also under load.
....Torsion Testing Machine (30Nm) can cater for test specimens of up to 750mm. Standard hexagon drives are used for transmitting the torque into the specimens. An angular compensation system is integral to the torsion head with a dial gauge. The Torsion Testing Machine (30Nm) head measures the applied torque to the specimen using strain gauge technology. Data Acquisition Software is supplied to capture the test parameters and to display the graphs relevant to further work. The strain gauge signals are fed directly into the Data Acquisition Interface supplied.
Experimental Capabilities:
Torsional variation due to material, cross sectional area
Torsional loading to failure of varying material specimens
Determination of the Modulus of Rigidity and Yield shear stress
Working with the elastic torsion equation
Comparison between actual and theoretical results
Intended use:
Used as cover glass for microscope slides in standard transmitted light microscopy. For clinical laboratory use.
Microscopic examination of clinical specimens in hematology, microbiology, cytology and pathology laboratories in referral or teaching hospitals.
Microscope frame with 360 degree revolving 30 degree inclined binocular tube.
Third ocular allows for integration of camera via C-mount, with 0.5x reduction.
Range of magnification 40 to 1000x.
5-positions nosepiece.
Objectives, full plan-achromatic 5x/0.12.
Condenser: Abbe with iris diaphragm aperture, 1.25 NA.
Eyepieces: 16x-eyepieces optionally.
Area of stage: 210 mm (w) x 145 mm (d); travel range: 75 mm (w) x 30 mm (d)
Single slide holder.
Rack and pinion steel gears.
Coarse and fine focusing: fine focus: 0.4mm/rotation.
Retractable eye guards.
Illumination: average life-time of LED: more than 20.000 hours.
Sensor 1/ 2.5 CMOS.
Exposure time, automatic / manual 2s to 0.01ms.
Video imaging up to 20 frames per second.
Observation by Bright field and with blue filter.
Brightness control 0 to 100 % (linear).
Camera with software: Digital still image and video capturing, processing and storage/retrieve software.
Operation conditions: 10°C to 40°C, air humidity max. 75% at 35°C.
Resolution still image: 2560 (H) x 1920 (V) 5 Megapixels.
Provided with USB 2.0 power and data connection to external computer.
Windows XP compatibility: Windows 10 embedded x64 and older Windows x64 systems.
Blood collection needle for use with vacuum tubes. For use in clinical phlebotomy.
Blood collection needle.
Sterile, individually packed in a twist-apart plastic container.
Material; Medical grade stainless steel.
Length approx. 40 mm
Diameter 20 G (0.9 mm)
Applicable for multi-sample draw.
Needle fits (screw in and out) needle holder.
Pointed at both ends, with rubber sleeve on the posterior end needle.
Vaccine storage capacity: 0.8 litres
Vaccine carrier, Small, Short range
With lid and shoulder strap.
Cold life at 43°C without openings: 20 hours 16 minutes
Supplied with 2 x 0.4L icepacks as a standard.
Weight fully loaded: 2.18 Kg
Vaccine storage capacity: 211L
Volume category: >/= 120L
Refrigerant: R600a, 80 grams
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF- Grade A
Prequalified Intermittent Mains Powered Refrigerator for storage of vaccines at +2 ?C to+8?C.
Equipment operating voltage and frequency: 220-240 Volt and frequency 50Hz / 60Hz, 1ph.
Vaccine storage capacity: 46.5 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +10 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 38 grams
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
The USB Interface Cradle is supplied with a 1-meter micro-USB to USB-A cable for connection to a PC and can be used to download data from multiple 30DTRs consecutively. The USB Interface Cradle serves as the physical data connection between a 30-Day Temperature Recorder (30DTR) and a PC for temperature data download.
....Capacity: 256L
Cabinet Type: Upright
Adjustable cabinet temperature set point -40C to -86C in 1°C increment., the temperature regulation accuracy is 1° C.
Volume Category: ≥ 80 <300L
Storage temperature: up to-86°C
Operating ambient temperature: +10 °C - +27°C (Moderate zone)
Power requirement: 220-240V/50Hz and upon request 110V/60Hz
Blackboard triangle/set square with detachable handle, 30-60-90º, longest side 60cm, 5mm thick plastic, graduated in cm on all sides.
....Medical-grade pen light, pre-focused
Diagnostic pen light, generally used to check patient’s pupils.
Material of the simulator: Thermoplastic polyurethane - TPU (primary material for body skin), Polyvinylchloride - PVC (primary material in chest and face skin) silicone rubber, Polyoxymethylene - POM, polypropylene - PP, and iron/steel.
Full term anatomically accurate newborn with umbilical cord.
Texture of the simulator: soft and smooth, friction free to demonstrate the desired procedures. Realistically sculpted to resemble and simulatea baby, anatomically accurate and feeling smooth / resilient / bony as relevant and suitable for simulation.
Material: Polypropylene, autoclavable.
Overall height: approximately 120mm.
Depth: approximately 110mm.
Internal diameter: approximately 30mm.
Nasal cannula (nasal prongs), device designed for easy administration o foxygen into the patient nose through two small prongs placed in the nostrils, providing comfort for the patient.
The device consists of:
Material: Preferably soft and kink resistant polyvinyl chloride (PVC).
Star lumen main tube to avoid accidental blockage.
Over-the-Ear tubing adjustable
Soft funnel shaped connector to facilitate easy connection to oxygen source.
Soft twin prongs nasal tips to ensure equal oxygen flow to both.
Adjustable, smoothly finished nasal tips for maximum patient comfort.
Length of the oxygen tube: +/- 2 m.
Size selected: Child
Single use.
Non-sterile.
It is designed to allow sterilization of the enclosed medical device and also to maintain sterility of the device until the packaging is opened for use of the device, or until a predetermined shelf date is expired. This is a single-use device. Paper sheets intended to be used to contain medical devices that are to be sterilized.
....