Training Objectives:
To investigate how the solar irradiation influences the solar panel output voltage
To obtain a daily irradiation curve
To test the complete system
To cover the solar panel with different materials
To calculate the inner resistance of the solar panels
To use both solar power and energy stored in the battery to power the DC load
To charge the battery using solar energy.
Wall mounted apparatus (for loading spiral springs in either tension or compression with direct gravitational loads) with accurately divided scale and vernier.
Supplied complete with four compression and four extension springs each approximately 18 cm long (7") long. Mass Hanger and Masses for (Hanger 1, Masses 13 x 1 kg)
Experimental Capability:
Modulus of rigidity for spring material.
Introduction to Spring Rate
Determines load and deflection relationships for close coiled springs.
Intended use:
Capping tool for quickly and easily installing PCR Cap strips onto PCR tubes and plate ensuring proper sealing.
Vaccine storage capacity: 15 litres
Cold box, Small, Short range
With hinged lid and carrying handles.
Cold life at 43°C without openings: 53 hours 36 minutes
Supplied with 32 x 0.4L icepacks as a standard.
Weight fully loaded: 33.85 Kg
Vaccine storage capacity: 55.5 L
Volume category: <60 L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
PQS prequalified Solar direct drive refrigerator with no battery for storage of vaccines at +2 ?C to+8?C in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
Refrigerant: R600a, 50 grams.
The Paint Brush has an excellent application and provides a smooth finish
Brush, paint, for use with two-component paint
Length of bristles: minimum 49mm, maximum 73mm
Width of paintbrush: minimum 50mm, maximum 60mm.
Thickness of brush head: minimum 14mm, maximum 18mm
Synthetic filament preferred.
Medical gas flow meter (Thorpe tube design) to regulate and measure the flow rate of medical gas supplied to a patient, maximum flow rate 15 LPM, for medical oxygen.
Graduation shall have over 270 degrees of visibility.
Needle valve and body constructed of brass or aluminium.
Calibrated at 50-55 psi / 345-380 kPa / 3.4-3.8 bar inlet gauge pressure.
Inlet pressure (nominal) > 50 psi (345 kPa / 3.45 bar), peak inlet pressure at least 100 psi (690 kPa / 6.89 bar).
Pressure compensated design to give specified accuracy for whole range of input pressures
Thorpe tube design flow meter using DISS input connector for panel /regulator mounting.
Can be cleaned with damp cloth and a disinfection solution.
Transparent, graduated (metric system) column, shatter resistant polymer certified for medical use.
Built-in inlet filter (depending on supplied model).
Maximum flow rate when fully opened: 50 L/min (depending on supplied model).
Adjustment knobs to have rough surface to prevent slipping.
Inlet and outlet connectors DISS style, other types of connectors available upon request.
To hold compatible blade for surgical incisions.
To be used with: Scalpel blade no. 10, Scalpel blade no. 11.
Medical examination gloves used for medical procedures to protect both patient and medical staff from cross-contamination. Examination gloves are non-sterile and strictly SINGLE USE.
....One size fits all sling for spring scales, for newborn and infants aged 0-6 months.
Strong, durable and easy to clean fabric, comfortable for the baby, soft and flexible but non-elastic.
Seams with double stitching.
Square shape.
Lengths of the straps: 40cm, +/- 10%
Measurements of the sling: square shape, 80 x 80cm, +/- 5%
Can hold an infant up to 5 kg
With straps/handles for suspension from spring scale: 2 straps, each strap to be fitted with both ends on 2 parallel corners of the sling.
Material:
Material does not shrink more than 10% with the above indicated washing.
Machine washable up to 40°C with domestic type detergent.
This bladder tank should be specifically designed for use on trucks for water transport.
Collapsible (flexible) water tank (bladder) manufactured from UV resistant, food grade PVC coated polyester fabric (minimum 1100 g/m2), fitted with inlet and cap on top of the tank. All materials used should be suitable for use with chlorinated drinking water.
Dimensions of the tank: 4m long, 2.2 m wide and 0.65 m high (maximum 6 tons capacity).
Forged from high grade Selected Alloy with head set at 15 degree
Heavy duty impact spanner with strong profiled handle and durable striking end.
Three Scale Balance
....It consists of a bottom plate,Straight tube,cylinder cover and the support.
This product can be used in conjunction with glass stick,glue stick and a bar magnet.
Screw adjustability, applicable to all kinds of different thickness of latex tube water.
....Plastic, ≥1L. Air pressure spray bottle.
....Wet and Dry Bulb Thermometer
....Pointer electroscope:square electroscope metal shell, with a banana security terminal negative, connected to the pointer on the base, with a positive terminal of the ball and 2 with positive terminal tray.
....Replacement for Measurement Chamber Lid of turbidimeters.
For Use With (Equipment): Turbidimeter.
Type: Chamber Lid