Rectangular mosquito net, polyester 100 DENIER, treated with WHO PQ qualified insecticide, colour white/blue/green, dimensions 190 x 180 x 180 cm (length x width x height) +/-5%.
....Multi-wavelength photometric measurement at chemical reaction end-point (667 nm - maxi absorbance point, and 840 nm - turbidity compensation).
Provides direct reading from inserted micro-cuvette.
Automated point-of-care device for measuring glucose in capillary whole blood.
Technology: optical absorption and reflectance photometry.
Sample size: 5 to 10uL capillary, venous or arterial whole blood.
Sample collected directly from skin surface into single-use microcuvette by capillary action.
Uses dedicated microcuvette (closed system).
Removable microcuvette holder to allow for easy cleaning.
Correlation with reference laboratory measurements: 0.99
Factory calibrated and continuous built-in auto self-test (when switched on). Needs no further calibration.
Measuring range: 0 to 500 mg/dL.
Read-out in: mg/dL or mmol/L.
Reading time: 40 sec. to 4 min.
Interfaces: RS 232 to printer or computer.
Power supply: 220V /50 or 4 x type AA / R6 1.5 V batteries (allowing for 100h to 150h continued usage).
Display informs: glucose reading, reading errors, systems errors, battery status.
Symbols in display facilitate multi-lingual understanding.
Built-in memory, storing > 400 measurements.
Supplier’s product reference: HemoCue Glucose 201+ analyzer starter set/kit.
Intended use:
Storage box for standard microscope slides with a size of 7.6 x 2.6 cm.
Suitable for use in resource-limited settings. For the separation of heterogeneous mixtures or samples in clinical laboratory applications.
....Used for multiple techniques to accurately dispense required volumes of liquid.
A handle with digital setting and read-out of delivered volumes
Autoclavable, and Resistant to UV sterilization
Built-in tips ejector
Manual air displacement micropipette
Single channel, adjustable pipetting volumes 20-200ul
Compatible with universal fit pipette tips ranging 20-200ul
Sturdy and chemical resistant parts.
Designed for blood sample collection, preserves nucleic acid in the dried blood spots for subsequent laboratory tests.
To collect and transport dry blood specimens for early infant diagnosis of HIV
Dry blood spot (DBS) absorbent filter paper.
Stability: Minimum 24 months for DNA.
DNA, DNase, RNase, & PCR inhibitor.
With 5 distinct pre-marked spots.
Spots are pre-perforated / pre-punched, facilitating processing in PCR applications.
Anti-AB blood grouping reagent
Volume: vial of 10ml
Contains monoclonal murine IgM antibody
Dropper bottle
Box of 10 vials.
Set of winter clothing for child aged 1 to 2 years.
....Vaccine storage capacity: 1.7 liters
With lid, shoulder strap and backpack.
Cold life 33 hours 42 minutes at 43°C without openings.
Supplied with 4 x 0.6 liter icepacks WP0.6L as a standard.
Weight fully loaded: 8 kg.
Foster Walk-in type cold room, mono block, 40m3 for storage of vaccines at national and sub-national levels.
Internal dimensions: L=4260 x W=4260 x H=2100 mm
External dimensions: L=4460 x W=4460 x H=2300 mm
Icepack with screw cap
Capacity: 0.6 litres
External dimensions: 190 x 120 x 34mm, +/- 2mm
Water content: 0.55 to 0.6 litres
Removable cap, with internal water seal to prevent leakage.
Filling line indicated on one side.
Walls to be reinforced to prevent swelling.
Supplied empty.
Gros volume-Freezer: 105 L
Volume category: <150L
Refrigerant: R600a, 58 grams
Energy consumption, stable running (kWh/24 hours): 2.24
Equipment operating voltage and frequency: 220-240 Volt 50Hz /60Hz, or 100-127 Volt 50Hz /60Hz, 1ph.
Operating temperature: Max rated ambient temperature: +43°C
PQS Prequalified Mains Powered Vaccine/Water-Pack Freezer for storage of vaccines at -15?C to -25?C and freezing of water packs.
Vaccine storage capacity: 36 L
Volume category: <60L
Solar radiation reference period of 3.5 kWh/m²/day and hot zone (+43°C) test temperatures.
Operating temperature: Min and Max rated ambient temperature: +5 °C and +43°C
UIFPF: Grade A
Refrigerant: R600a, 60 grams
PQS prequalified Solar direct drive combined refrigerator and freezer with no battery for storage of vaccines at +2 ?C to+8?C and freezing of ice packs in areas without any electricity, or where there is less than eight hours of reliable electricity over a typical day.
The device indicates via a visual alarm when an exposure to temperatures below -0.5°C for longer than 60 minutes has occurred. The device needs to be activated prior to use and once an alarm has been triggered, cannot be re-used. The Freeze Alert is an electronic Irreversible Freeze Indicator (IFI) with an internal sensor, factory-programmed alarm, and visual display for indicating a freeze event during transport or storage of freeze-sensitive vaccines.
....Cabinet Type: Upright
Capacity: 707L
Storage temperature: up to-86°C
Volume Category: ≥ 600 <900L
Power requirement: 220-240V/50Hz and upon request 110V/60Hz
Operating ambient temperature: +10°C to +32°C (Temperate zone)
Adjustable cabinet temperature set point -40°C to -86°C in 1°C increment., the temperature regulation accuracy is 0.1°C.
Data mode: Selective repeat ARQ Protocol, 2400 bps-16 channel QPSK modulation.
Transceiver Interface: 9600 baud RS232; TR.29 based AT port.
Primary Power: 13.5V DC nominal (250 mA max), 9-16V DC operating range.
Link establishment mode: Proprietary link establishment 80 baud CHIRP.
Temperature: 0°C to 55°C.
Data compression: In-built data compression.
Rate of data transfer: Up to 6000 pbs (compressed), Up to 1475 bps (uncompressed).
Size: 210mm W x 240mm D x 65mm H (including rear connectors).
Weight: 1,8kg.
Non-toxic, bright, assorted colors; packed in neutral film in easy separable blocks, over-packed in supplier's own packaging. Clay, modeling, box of minimum 6 - maximum 8 sticks with a total weight of 500g.
....Science teaching Kit packed in a metal box.
The primary science Kit consists of 32 items including instruction manuals and metal box. It is mainly for teacher’s demonstration also can be used for student activities. Primary science teaching aids Kit is designed for schools grade 1-6. Some consumables materials, such as batteries, iron nails, red ink, etc. are not included in the Kit and those can be easily obtained locally.
Decal, equipment, permanently adhesive
Roll of 50
Material: White gloss PVC with permanent adhesive, 0.1mm thickness, lifespan 2-3 years from date of delivery, Kraft liner 67 grams.
Base color: 100% Cyan blue. The logo are printed in white, and positioned in the middle of the decal, running 80% of the length.
Decal, rectangular, 205 x 105mm, roll of 50 decals
Size: Rectangular, length 205 mm x height 105 mm, with corners in a 90-degree angle.
Wooden figures for table play; includes figures of domestic and wild animals, people, trees, etc. Set of approximately 100 figures all contained in either box or bag for storage. Coloured, smooth wood with non-toxic finish. Minimum size 50mm (2"); firmly based for standing.
....